The VMware vRealize Operations Management Pack for vRealize Network Insight integrates alerts that are unknown to vRealize Operations Manager. These alerts are added to vRNI Others. You can enable or disable the generation of alerts on vRNI Others using the VRNI_IS_ALERTS_ON_VRNI_OTHERS_ENABLED property. To do so, stop the adapter instacne, make the property changes on all the nodes, and start the adapter instance.

This Management packs gathers information on the inventory of the data sources configured in vRealize Network Insight. These data sources must be configured as end points in vRealize Operations Manager.

From the Alerts tab or from the Inventory, you can troubleshoot issues by getting the insights of object on which the alert is triggered by using launch-in-context to vRealize Network Insight.

For the alerts or notifications without any object mapping in the inventory, you can launch-in-context to either problems or user defined events of vRealize Network Insight.

In the Inventory, the launch-in-context option is available only for the following objects:

End Point

Object

vCenter

  • ComputeCluster

  • HostSystem

  • Virtual Machine

  • vCenter

  • Virtual Machine Traffic Details

NSX-T

  • EdgeCluster

  • LogicalSwitch

  • Management Node

  • Transport Node

NSX for vSphere

  • NSX Controller

  • Edge Device

  • Controller Cluster

  • Manager

VRealize Network Insight

  • vRNI Others

This Management Pack collects the user defined events of vRealize Network Insight as notifications. It pulls the user defined events generated in last six hours from vRealize Network Insight to vRealize Operations Manager, as notifications. To increase or decrease this time interval, edit the VRNI_USER_DEFINED_EVENT_OVERLAP_IN_HOURS property in NetworkInsight.properties.
The following alerts are triggered when any of the monitoring resources in vRealize Network Insight management pack display an unexpected behavior.
Table 1. Alerts in Management Pack for vRealize Network Insight

Alert Definition

Recommendations

Event ID

Resource Kind

MP Version

vRNI-Security Fabric Agent not reported by NSX for a Host which belongs to a prepared cluster

  1. Check if the Host is prepared properly by the NSX Manager. Look for any error for the specified Host, Check the state of Check Point Service VM on the specified Host.

  2. Try rebooting the virtual machine.

CheckpointNsxFabricAgentNotFoundOnHostEvent

HostSystem

1.0

vRNI-Compute Managers Not Added

COMPUTE_MANAGERS_NOT_ADDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A distributed firewall ruleset was not applied to a host.

  1. Verify that the specified Host was properly prepped by NSX Manager.

  2. Check if the vsfwd process is running on the Host and the network connection is established between it and NSX Manager.

  3. Force sync firewall config using ForceSync API or from UI.

  4. If the problem still persist, please collect ESX and NSX Manager tech support bundle and open a SR with VMware technical support.

RulesetLoadOnHostFailedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-All VTEPs are deleted from the transport node. VMs might lose connectivity because of this.

Make sure VTEPs/Vmknics are not deleted from the transport node.

NSXTVtepDeleteEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Logical Switch Admin Status is 'Down'.

Please enable the NSX-T Logical Switch Admin Status in NSX-T.

NSXTLogicalSwitchAdminStatusDownEvent

LogicalSwitch

1.0

vRNI-Latency collection was disabled in the NSX-T Manager after it was enabled by Network Insight. As a result, Network Insight is not receiving latency information from the NSX-T.

NSXT_LATENCY_NOT_ENABLED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Unable to send email message.

UNABLE_TO_SEND_EMAILS_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T controller node has lost management plane connectivity.

Check if the node has proper network connectivity with management plane.

NSXTControllerNodeToMgmtPlaneConnectivityEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-SNMP Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceSNMPStatusEvent.recommendation-0.

NSXTMPNodeServiceSNMPStatusEvent

ManagementNode

1.0

vRNI-vCenter managing one or more fabric nodes in NSX-T is not added as a data source in vRNI. Virtual Machines on those hosts will not be visible in vRNI.

Add the vCenter server managing the standalone hosts as a datasource into vRNI.

NSXTStandaloneHostsEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Flow processing suspended

FLOW_PROCESSING_SUSPENDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Considerable count of packet drops detected at specified switch port

Check the state and MTU of specified switch port.

SwitchPortPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Retransmitted Packet Event on Edge for Application.

Verify that the Link is in healthy state.

VeloCloudEdgeL7ApplicationRetransmittedPacketEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Tunnel Status is 'Unknown'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTHostNodeTunnelStatusUnknownEvent

TransportNode

1.0

vRNI-Not Empty Node

NOT_EMPTY_NODE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Infoblox credentials are invalid or the user does not have the "API Privilege" to access Infoblox data

INCORRECT_INFOBLOX_CREDENTIAL_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Hardware Gateway Bindings Mismatch between NSX and switch

EventInfo.HardwareVTEPMismatchEvent.recommendation-0.

HardwareVTEPMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The NSX infrastructure VM found to be in powered off state. Services provided by it may get impacted. The NSX infrastructure includes Controller cluster, NSX Manager, and one or more Edge VMs.

  1. Power on the specified NSX infrastructure VM.

  2. Check if the host on which this VM is deployed is accessible.

ServiceVMNotPoweredOnEvent

VirtualMachine

1.0

vRNI-vRealize Network Insight Content Pack version not supported

UNSUPPORTED_vRNI_CONTENT_PACK_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Roll-up Status is 'Unknown'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTEdgeNodeStatusUnknownEvent

TransportNode

1.0

vRNI-Underlay device module removed or not working event.

Check the specific module on underlay device.

UnderlayDeviceModuleMalFunctionEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Pnic Status is 'Down'.

Please check if all the pNICs are properly connected.

NSXTEdgeNodePnicStatusDownEvent

TransportNode

1.0

vRNI-Underlay device power supply removed or not working event.

Check the specific power supply on underlay device.

UnderlayDevicePsMalFunctionEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-At least one of NSX VIB or host module was not detected on the host, and NSX operations may be affected. The VIB or module may have been unloaded manually by error.

  1. Check if the specified VIB is loaded and running on Host, In case of vsfwd module, check if the network connection is established between the specified module and the NSX Manager.

  2. In case of netcpa module, check if the network connection is established between the specified module and the NSX Manager.

  3. See also 'Host Preparation (UWA) Troubleshooting' in the NSX Troubleshooting Guide.

ModuleNotLoadedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more host VTEPs' IP addresses are not on the same subnet as other VTEPs in the same cluster. This condition may result in network connectivity issues

Assign the same IP subnet to all hosts in the cluster. You can use either DHCP or manually configured IP pools for VTEP IP addresses. See 'Configure VXLAN Transport Parameters' in the NSX Installation Guide.

VtepSubnetMismatchEvent

ClusterComputeResource

1.0

vRNI-Collector Port in Collector Profile is incorrect

NSXT_IPFIX_PORT_INCORRECT_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Invalid Credentials

INVALID_CREDENTIALS_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The host's fabric status resource feature version is not same as that of the cluster or NSX Manager

Check if the host is in connected state and can connect to NSX Manager.

HostFeatureVersionMismatchEvent

HostSystem

1.0

vRNI-Ipfix Flow Data Source has been paused due to large number of flows.

IPFIX_FLOW_DP_PAUSED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-No SNMP Targets are configured.

SNMP_NOT_CONFIGURED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Underlay device BFD session deleted event.

Check the BFD details on underlay device.

UnderlayDeviceBfdSessionRemovedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A service VM or gateway for Check Point does not have 'communicating' SIC status

Check that SIC is established with the Security gateway. Access the gateway object in SmartDashboard and confirm the SIC status.

CheckpointGatewaySicStatusNotCommunicatingEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The host's VTEP count doesn't match the VTEP count of other hosts in the same cluster. VMs on this host connected to a logical switch may not be able to communicate.

  1. Confirm the required TCP ports are open for communication between NSX Manager and the host, as described in 'VXLAN Preparation' in the NSX Troubleshooting Guide. You may need to resync the configuration.

  2. See 'VXLAN VMKNic Out Of Sync' in the Troubleshooting Guide. See also <a target.

VtepCountMismatchEvent

ClusterComputeResource

1.0

vRNI-Invalid Data Source Config

INVALID_CONFIG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more networks connected to an NSX Edge router are not reachable from an uplink router.

  1. Check the routes on the router connected to the uplink interface of the NSX Edge services gateway.

  2. Route to reach the edge should exist on the router connected to the uplink interface.

EdgeNetworksNotReachableEvent

LogicalRouter

1.0

vRNI-A threshold-crossing memory usage detected on host FRUs.

ThresholdExceededEventDataSourceMemoryUsage-0.

ThresholdExceededEventDataSourceMemoryUsage

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Host Not Reachable

HOST_NOT_REACHABLE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Flow Physical Node

FLOW_PHYSICAL_NODE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Node Management Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNodeMgmtStatusEvent.recommendation-0.

NSXTMPNodeServiceNodeMgmtStatusEvent

ManagementNode

1.0

vRNI-File required by Generic Routers & Switches Data Source does not exist

UANI_FILE_DOES_NOT_EXIST_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The data source identity information such as certificate or the key has changed.

DATASOURCE_IDENTIFICATION_CHANGED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of transmit-side packet drops have been detected on a host interface.

Check the state and MTU of the affected Host's interface.

ThresholdExceededEventNetworkTxDropRule

HostSystem

1.0

vRNI-Event generated as a result of the specified metric crosses the upper or lower bound specified in the configuration

AnalyticsThresholdEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Network Insight does not support the IPFIX flow data from NSX-T Switches. It is configured to send IPFIX data to one of the Network Insight Collector VM. It may have corrupted existing flow data in the system.

Remove Network Insight Collector VM IP Address from the NSX-T Switch collector profiles which are used in NSX-T Switch IPFIX profiles.

NSXTSwitchIpfixEnabledEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Tier-1 logical router is disconnected from Tier-0 router. Networks under this router are not reachable from outside and vice versa.

Connect Tier-1 Logical Router to Tier-0 Logical Router.

NSXTNoUplinkConnectivityEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Network Insight Collector VM is not receiving network latency metrics from host

  1. Ensure that the host is in healthy state.

  2. Ensure that there is no network connectivity issues between host and Network Insight Collector VM.

  3. Ensure that firewall is not blocking communication.

NSXVLatencyNoDataEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Fex fan removed or not working event.

Check the specific fan on fex device.

UnderlayDeviceFexFanMalFunctionEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Roll-up Status is 'Degraded'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTEdgeNodeStatusDegradedEvent

TransportNode

1.0

vRNI-NSX-T IPFIX DFW is not Enabled

NSXT_IPFIX_DFW_STATUS_NOT_ENABLED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Mismatch in service appliance information between NSX Manager and Panorama.

  1. Check the state of the Palo Alto NGFW virtual machine and ensure that it is booted properly.

  2. Confirm network connectivity exists between the Palo Alto NGFW virtual machine and Panorama.

  3. Confirm network connectivity exists between the Palo Alto NGFW virtual machine and NSX Manager.

PanNsxServiceApplianceViewMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Webhook not enabled for one or more alerts of vRealize Network Insight Content Pack in Log Insight

WEBHOOK_NOT_ENABLED_ON_ALERT_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Link State of VeloCloud Edge is not connected.

Verify that the VeloCloud Link is UP.

VeloCloudLinkDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The VTEP MTU does not match between a host and the NSX prepared cluster.

Check the MTU of all the VTEPs of hosts in the cluster. To change the MTU settings of deployed VXLAN port groups via the NSX API, please refer <a target.

ClusterHostsVtepMTUMismatchEvent

ClusterComputeResource

1.0

vRNI-Scheduled backups of the environment have not been configured

Configure scheduled backups for NSX Manager. See also 'NSX Backup and Restore' in the NSX Administration Guide.

NSXBackupNotScheduledEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Node Not Active

NODE_NOT_ACTIVE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSXT IPFIX Collector and Ipfix Profile Mismatch

NSXT_IPFIX_COLLECTOR_AND_IPFIX_PROFILE_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX Manager and the associated vCenter DataSources is not on the same Collector VM.

VC_NOT_ON_SAME_PROXY_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Syslog Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceSyslogStatusEvent.recommendation-0.

NSXTMPNodeServiceSyslogStatusEvent

ManagementNode

1.0

vRNI-VeloCloud Link Packet Loss Event Rx.

Verify that the Link is in healthy state.

VeloCloudLinkLostPacketEventRx

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Received packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected.

Check if there is MTU mismatch on the connected ports or any firewall rule is responsible for dropping of received packets.

NSXTLogicalSwitchReceivedPacketDropEvent

LogicalSwitch

1.0

vRNI-Panorama is not in a registered state with NSX Manager.

Check network connectivity between Panorama and the NSX Manager.

PanNsxNotInRegisteredStateEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-HTTP Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceHttpStatusEvent.recommendation-0.

NSXTMPNodeServiceHttpStatusEvent

ManagementNode

1.0

vRNI-The network fabric feature status for a host does not match the status of other hosts in the cluster.

Check if the Host is in connected state and can connect to NSX Manager. For more information, please see the 'Host Preparation' section in the NSX Troubleshooting Guide.

HostFeatureInstalledMismatchEvent

HostSystem

1.0

vRNI-Primary NSX Not Added

PRIMARY_NSX_NOT_ADDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-OSPF is enabled on the NSX Edge, but Interface to OSPF area mapping configuration is missing

Configure the OSPF to interface area mapping for the specified NSX Edge interface.

EdgeMissingInterfaceOSPFAreaMappingEvent

EdgeServicesGateway

1.0

vRNI-NSX-T Host Node Roll-up Status is 'Degraded'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTHostNodeStatusDegradedEvent

TransportNode

1.0

vRNI-NSX-T Edge Node has lost manager connectivity.

NSXTManagerConnectivityDownEvent

TransportNode

1.0

vRNI-NSX-T Host Node Pnic Status is 'Degraded'.

Please check if pNIC is properly connected.

NSXTHostNodePnicStatusDegradedEvent

TransportNode

1.0

vRNI-There are fewer than three controllers deployed, which increases the risk of an outage when a controller is down. Or even number of NSX Controllers are found to be deployed, which may cause the split brain and disrupt network connectivity

  1. Active controllers should be three or more, and odd in number, this allows to establish the controller majority.

  2. Verify that all NSX Controller VMs are powered on. See also the 'NSX Controller' section in the NSX Troubleshooting Guide.

NSXControllersDeployedCountEvent

ControllerCluster

1.0

vRNI-Host with Infrastructure VMs cannot be accessed

  1. Check for network connectivity issues using ping or by traceroute.

  2. Check if the host is in powered on state. If not, then power it on.

CriticalHostNotAccessibleEvent

HostSystem

1.0

vRNI-Incorrect Connection String

INCORRECT_CONNECTION_STRING_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Telemetry Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceTelemetryStatusEvent.recommendation-0.

NSXTMPNodeServiceTelemetryStatusEvent

ManagementNode

1.0

vRNI-Upgrade Failed

UPGRADE_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Data Source Failed

FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Received packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster.

Check the state and MTU of specified interface.

NSXTRxPacketDropOnEdgeTnNicEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-UI Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceUIServiceStatusEvent.recommendation-0.

NSXTMPNodeServiceUIServiceStatusEvent

ManagementNode

1.0

vRNI-A host in a cluster prepared for NSX is missing at least one VTEP. VMs on this host connected to any logical switch may not be able to communicate.

  1. Check the teaming policy, VLAN ID, and DHCP server status and IP pool, as well as confirm the required TCP ports are open on the host. See also 'VXLAN Preparation' in the NSX Troubleshooting Guide.

  2. Check the system events table for event code 1900 - VXLAN initialization failed on the host.

HostVtepNotFoundEvent

HostSystem

1.0

vRNI-Alarm/Event generated by NSX-T platform

NSXTSystemEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-AWS Throttling Exception

AWS_THROTTLING_EXCEPTION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Pnic Status is 'Degraded'.

Please check if all the pNICs are properly connected.

NSXTEdgeNodePnicStatusDegradedEvent

TransportNode

1.0

vRNI-Not Found

NOT_FOUND_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Duplicate MAC Address found on multiple ports

Ensure that the ports have unique MAC addresses.

UnderlayDuplicateMacAddressEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Controller Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceControllerStatusEvent.recommendation-0.

NSXTMPNodeServiceControllerStatusEvent

ManagementNode

1.0

vRNI-This event is raised when the number of VMs per Host in a VMC SDDC exceeds limits.

  1. Delete VMs in Host that are not in use.

  2. Add a new Host in VMC SDDC.

VMCVMPerHostLimitExceededEvent

HostSystem

1.0

vRNI-An IPSet with the same name and different scopes is defined in two NSX Managers. This condition may indicate a configuration error.

Check the specified IPSet's definition in all NSX Managers.

IPSetDefinitionMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Log Insight version not supported

UNSUPPORTED_LOG_INSIGHT_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The VXLAN segment ID ranges defined in different NSX Managers have overlapping ranges, which is not a VMware best practice.

  1. Ensure that the segment ID ranges in different NSX Managers do not overlap.

  2. See 'Assign a Segment ID Pool and Multicast Address Range' in the NSX Installation Guide.

SegmentMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-VeloCloud Edge Degraded Video QOE Event.

Verify that the Edge is in healthy state.

VeloCloudEdgeDegradedVideoQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX Edge VM is reporting a problematic state and might not be functioning correctly.

  1. An automatic force sync is triggered when a problematic state is detected.

  2. If the automatic force sync fails, try a manual force sync.

EdgeUnhealthyEvent

EdgeServicesGateway

1.0

vRNI-Data Retention (Metric Retention Configuration) service is unhealthy.

HBASE_RETENTION_TOOL_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when any system protection limit is exceeded

PROTECTION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The Latency Stat profile configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T.

NSXT_LATENCY_STAT_PROFILE_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The installed NSX feature is reported for some problem by NSX Manager.

Check the specified NSX feature installation status on the NSX UI and then sync the specified feature.

FeatureUnhealthyEvent

HostSystem

1.0

vRNI-Data Source Timeout

TIMEOUT_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Outbound Rules available with AWS Security Group.

AWSSGOutboundRuleLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Routing advertisement is disabled for NSX-T Tier-1 logical router. Networks under this router are not reachable from outside.

Enable route advertisement on Tier-1 logical router.

NSXTRoutingAdvertisementEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-VeloCloud Edge Degraded Trans QOE Event.

Verify that the Edge is in healthy state.

VeloCloudEdgeDegradedTransQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-No transport zone attached to the transport node. VMs might lose connectivity because of this.

Ensure that the transport node is attached to some transport zone.

NSXTNoTzAttachedOnTnEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The OSPF area ID differs on connected router interfaces.

Configure the same OSPF area ID for the DLR and Edge router interface mapping.

OspfConfigurationMismatchEvent

LogicalRouter

1.0

vRNI-Appliance is not registered for online services.

APPLIANCE_NOT_REGISTERED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-No NTP server is configured on the NSX Manager, likely impacting vCenter connectivity. The NTP server must be specified so that the SSO server time and NSX Manager time are in sync

  1. See 'Edit the NSX Manager Date and Time' in the NSX Administration Guide.

  2. If configuring the Lookup service or vCenter Server fails, verify that the NSX Manager and Lookup service appliances are in time sync. Ensure to use the same NTP server configurations on both NSX Manager and Lookup service. Also ensure that DNS is properly configured.

  3. For more information, see Configuring the SSO Lookup Service fails (2102041). Starting with NSX for vSphere 6.2.4, the /etc/ntp.drift file in NSX Manager is now included with the NSX Tech Support Bundle.

  4. Note: The ntp drift file from other NSX Components (such as ESXi and NSX Controllers) are not included as they are not collected as part of the NSX Tech Support Bundle.

NSXNtpServerEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more OSPF neighbors connected to the NSX Edge are down, which may result in connectivity issues for virtual machines connected to this NSX Logical Router.

  1. Use the routing commands at the Edge VM console. You may need to use the 'debug ip ospf' or 'debug ip bgp' commands and observe logs on the DLR Control VM or on the ESG console (not via SSH) to detect protocol configuration issues.

  2. Such issues often include mismatched timers, MTU values, BGP ASN, passwords, and interface to OSPF area mapping.

NSXOspfNeighborDownEvent

EdgeServicesGateway

1.0

vRNI-A threshold-crossing amount of buffer usage have been detected on a switch port.

Check the state and MTU of specified switch port.

SwitchPortBufferThresholdExceededEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-When two Edge VMs have been configured for Edge high availability, this event indicates that one of the VMs is not powered on or both Edge VMs reside on the same host.

  1. Verify that the VMs are deployed on different hosts.

  2. Verify that both VMs are powered on.

EdgeNotHAEvent

EdgeServicesGateway

1.0

vRNI-NSX-T Logical Port Operational Status is 'Unknown'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another.

NSXTLogicalPortOperationalStatusUnknownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-FEX offline event.

Check the specific fex on underlay device.

UnderlayDeviceFexOfflineEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-User defined Problem when search result is empty

EmptySearchStreamProblemEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Security Fabric Agent not reported by NSX for a Host which belongs to a prepared cluster

  1. Check if the Host is prepared properly by the NSX Manager. Look for any error for the specified Host, Check the state of Palo Alto NGFW virtual machine on the specified Host.

  2. Try rebooting the virtual machine.

PanNsxFabricAgentNotFoundOnHostEvent

HostSystem

1.0

vRNI-NSXT IPFIX Ipfix Profile Priority not zero

NSXT_IPFIX_IPFIX_PROFILE_PRIORITY_NOT_ZERO_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Insufficient Role for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility.

BIGIP_INSUFFICIENT_ROLE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Same Switch or Router is added with different IPs. VM to VM path may not be generated.

Delete duplicate Switches or Routers from Data Source.

DuplicateL3SwitchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Considerable count of packets drop detected in VTEP underlay

VTEPUnderlayPacketDropEvent-0.

VTEPUnderlayPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when pool of load balancer is empty. To know pools which are empty, search 'Pool where PoolMembers Count

Ensure that pool has at least one pool member.

LBPoolEmptyEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of receive-side packet drops have been detected on a host interface.

Check the state and MTU of the affected Host's interface.

ThresholdExceededEventNetworkRxDropRule

HostSystem

1.0

vRNI-Last data collection on collector was more than threshold ago

COLLECTOR_LAG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A firewall, NAT, load balancer, or VPN service is running on this NSX Edge with ECMP enabled

Disable all Stateful Services (Firewall, NAT, Load Balancer, and VPN) on this NSX Edge.

EcmpIsEnabledAndStatefulServicesAreUpEvent

EdgeServicesGateway

1.0

vRNI-Distributed Firewall is disabled in the NSX-T Manager.

Please enable DFW Firewall from the NSX-T Manager.

NSXTDFWFirewallDisabledEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Platform Client Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNSXPlatformClientStatusEvent.recommendation-0.

NSXTMPNodeServiceNSXPlatformClientStatusEvent

ManagementNode

1.0

vRNI-Data Retention (Config Store Maintenance) service is not healthy.

FDB_CONFIG_STORE_CLEANUP_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Up time is less than expected

Check the operational status of the specified switch port.

SwitchPortUptimeThresholdRecededEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Secure FTP is not currently being used for backups, which could compromise backup data

  1. Use Secure FTP(SFTP) protocol for saving backups.

  2. For configuration assistance, refer to the 'NSX Backup and Restore' section in the NSX Administration Guide. Note - when upgrading to NSX 6.3.0.

  3. See also <a target.

NSXUnsecureBackupEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Assigned deployment definition is not matching the expected one.

DEPLOYMENT_DEF_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Hostname Resolution Error

HOSTNAME_RESOLUTION_ERROR_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Pnic Status is 'Unknown'.

Please check if all the pNICs are properly connected.

NSXTEdgeNodePnicStatusUnknownEvent

TransportNode

1.0

vRNI-NSX-T Manager backup is not scheduled.

Configure scheduled backups for NSX-T from the NSX-T Manager.

NSXTClusterBackUpDisabledEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Transmitted packets are getting dropped on the NSX-T Logical Port and associated entities might get affected.

Check if there is MTU mismatch on the port or any firewall rule is responsible for dropping of transmitted packets.

NSXTLogicalPortTransmittedPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Insufficient Partition Access for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility.

BIGIP_INSUFFICIENT_PARTITION_ACCESS_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The host's VTEP has been disabled and is in a not connected state.

Check the connection state of VTEP vmknic on host. Go to Hosts and Clusters > host > Manage > Networking > Virtual Switches.

HostVtepDisconnectedEvent

HostSystem

1.0

vRNI-All NSX Controllers in the cluster are deployed to the same host, which limits redundancy

Move the NSX Controller VMs to different hosts. VMware recommends configuring a DRS anti-affinity rule to prevent the controllers from residing on the same host.

NSXControllersVMOnSameHostEvent

ControllerCluster

1.0

vRNI-PostgreSQL Vacuum service is unhealthy.

VACUUM_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A Palo Alto Networks' security appliance VM was not found on a host in an NSX prepared cluster.

Check the state of the Palo Alto NGFW virtual machine on the specified host. Ensure that it is booted properly.

PanNsxServiceVMNotFoundOnHostEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The collector configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T.

NSXT_LATENCY_COLLECTOR_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Azure Network Watcher permissions for fetching Storage Account IDs corresponding to Azure Network Security Group not available

AZURE_NETWORK_WATCHER_STORAGE_ERROR_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Grid processing has stopped.

GRID_PROCESSING_STOPPED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Liagent Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceLiagentStatusEvent.recommendation-0.

NSXTMPNodeServiceLiagentStatusEvent

ManagementNode

1.0

vRNI-NSX System events with high or major severity

Not Available.

GenericNSXSystemEvent

Manager

1.0

vRNI-One or more VMs are not protected by NSX-T DFW firewall. Network Insight will not receive IPFIX flows for these VMs.

Remove the relevant logical switches, logical ports or security groups from the NSX-T firewall exclusion list to enable flows.

NSXTExcludedVmFlowEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Incorrect webhook configuration found for one or more alerts of vRealize Network Insight Content Pack in Log Insight

INCORRECT_WEBHOOK_CONFIGURED_ON_ALERT_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Number of Vms or Hosts Not Found

NUM_VMS_OR_HOSTS_NOT_FOUND_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Data is currently being re-indexed. Search service will be available after this migration activity is complete.

REINDEXING_IN_PROGRESS_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T System Event API is taking longer than expected time to execute.

NSXT_SYSTEM_EVENT_API_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Fex power supply removed or not working event.

Check the specific power supply on fex device.

UnderlayDeviceFexPsMalFunctionEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Grid processing is lagging by more than threshold ago

GRID_PROCESSING_LAG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-System events are currently excluded from backup, which could cause loss of security-related events

Enable backups of NSX Manager system events from the NSX Manager UI by going to Manage > Backup and Restore.

NSXBackupSystemEventsExcludedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Packet Drop Event on Edge for Application.

Verify that the Link is in healthy state.

VeloCloudEdgeL7ApplicationLostPacketEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-File required by Generic Routers & Switches Data Source not provided

UANI_FILE_NOT_PROVIDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX System events with critical severity.

Not Available.

OtherCriticalNSXEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Received packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster.

Check the state and MTU of specified interface.

NSXTRxPacketDropOnMPNicEvent

ManagementNode

1.0

vRNI-The NSX DLR is not configured with default route and may prevent external communication

1.Check if the router configuration is only for routing between internal networks, or if external access is required.

2.If external access is required, then configure an uplink interface on the NSX distributed logical router.

LogicalRouterNoUplinkEvent

LogicalRouter

1.0

vRNI-VeloCloud Link Degraded Voice QOE Event.

Verify that the Link is in healthy state.

VeloCloudLinkDegradedVoiceQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Insufficient Privileges

INSUFFICIENT_PRIVILEGES_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Transmitted packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected.

Check if there is MTU mismatch on the connected ports or any firewall rule is responsible for dropping of transmitted packets.

NSXTLogicalSwitchTransmittedPacketDropEvent

LogicalSwitch

1.0

vRNI-Majority of NSX Edges in the ECMP Cluster are currently down, which has significantly degraded the capacity of the cluster

Verify that the VM for each NSX Edge is running.Verify that the VM for each NSX Edge is connected to the network.

NSXMajorityEcmpEdgesDownEvent

EdgeServicesGateway

1.0

vRNI-Data Source Not Running

DATA_PROVIDER_NOT_RUNNING_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Firewall configuration update to an NSX host has timed out. The host is not synced with the latest firewall configuration version.

  1. Check if the vsfwd process is running on the specified host.

  2. Use CLI commands to verify if the rule realization is working properly or not on the affected Host.

  3. If the problem persists, collect ESXi and NSX Manager tech support bundles and open an SR with VMware technical support.

ConfigUpdateOnHostFailedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Switch Port is operationally down.

Check the operational status of the specified switch port.

SwitchPortOperationalDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when the number of Hosts in a VMC SDDC exceeds limits.

Deploy a new VMC SDDC.

VMCHostLimitExceededEvent

VMwareAdapter

1.0

vRNI-VDR port is not found on the Host for the specified VXLAN, which might create routing issue.

VirtualDistributedRoutingEvent

HostSystem

1.0

vRNI-High Disk Utilization

HIGH_DISK_UTILIZATION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-BFD profile was deleted on NSX-T Manager after "Enable Virtual Infrastructure metric collection" was enabled at Network Insight

NSXT_LATENCY_NO_BFD_PROFILE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Manager Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceManagerStatusEvent.recommendation-0.

NSXTMPNodeServiceManagerStatusEvent

ManagementNode

1.0

vRNI-The connection between the control plane agent on an NSX host and its primary NSX Controller for one or more logical switches is not established. This condition can result in stale information on the host and NSX Controllers.

  1. Check if all the NSX Controllers are accessible from the Host, Check if the netcpa process is running on the host, Check if the network connection is established between netcpa process on the Host and NSX Controllers.

  2. See 'Control Plane Agent (netcpa) Issues' in the NSX Troubleshooting Guide.

  3. Check if the network connection is established between netcpa process on the Host and NSX Controllers.

HostNetworkControlPlaneConnectionFailureEvent

HostSystem

1.0

vRNI-Devices with Port-channel Member interfaces connecting to Non-port-channel Members

Ensure that the peer port of a port channel is a port channel as well.

UnderlayPortChannelMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Some of the NSX Controllers in the cluster are not communicating with the NSX Manager, which is preventing the cluster from establishing a majority

  1. Verify that all NSX Controller VMs are powered on.

  2. Verify that all NSX Controller VMs are connected to the network. See also the 'NSX Controller' section in the NSX Troubleshooting Guide.

  3. Execute the show control-cluster status command on all controller nodes and look at the 'Majority status' value. This value should read 'Connected to cluster majority'.

NSXControllerClusterMajorityEvent

ControllerCluster

1.0

vRNI-NSX-T Compute Manager Connection status is not up.

Please check connectivity between NSX-T Compute Manager and NSX-T.

NSXTComputeManagerConnectionStatusNotUpEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The logical switching and routing information on a host is not in sync with the NSX Controller information

  1. Check if all the NSX Controllers are accessible from the Host, Check if netcpa process is running on the Host.

  2. See 'Control Plane Agent (netcpa) Issues' and 'Troubleshooting Controller Cluster' in the NSX Troubleshooting Guide.

HostNetworkControlPlaneNotSyncedEvent

HostSystem

1.0

vRNI-IPFIX cannot be enabled since no DVS found

NO_DVS_AVAILABLE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of packet drops have been detected on the vnic interface of an NSX Edge Gateway.

Check the state and MTU of specified interface.

RouterInterfacePacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX Manager attempted to re-establish the message bus channel when the prepared host connected back to vCenter Server. This connection again failed, and dependent NSX services were not notified.

  1. Check if the vsfwd process is running on the Host.

  2. Check if the network connection is established between vsfwd process on the Host and the NSX Manager.

  3. See also <a target.

HostMessagingConfigurationFailedEvent

HostSystem

1.0

vRNI-One or more Kubernetes Cluster's Kube Config file in PKS is not valid.

PKS_KUBERNETES_UNKNOWN_HOST_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A backup of the environment has not been performed. Proper backup of all NSX components is crucial to restore the system to its working state in the event of a failure

Configure scheduled backups for NSX Manager or take an immediate manual backup. See also 'NSX Backup and Restore' in the NSX Administration Guide.

NSXBackupNotRecordedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Password Authentication Mode Disabled

PWD_AUTH_MODE_DISABLED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Pnic Status is 'Unknown'.

Please check if pNIC is properly connected.

NSXTHostNodePnicStatusUnknownEvent

TransportNode

1.0

vRNI-BGP Neighbor is not in established state.

NSXTBGPNeighbourStateEvent

TransportNode

1.0

vRNI-Port Mode setting (access/trunk) of underlay switch ports do not match

Ensure that the port mode of both the ports match.

UnderlayPortModeMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A service VM or device for Palo Alto Networks is in a not connected state with Panorama

Check network connectivity between Panorama and the specified Palo Alto service VM.

PanDeviceInDisconnectedStateEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Received packets are getting dropped on the NSX-T Logical Port and associated entities might get affected.

Check if there is MTU mismatch on the port or any firewall rule is responsible for dropping of received packets.

NSXTLogicalPortReceivedPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Roll-up Status is 'Down'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTEdgeNodeStatusDownEvent

TransportNode

1.0

vRNI-One or more NSX Edge interfaces are down.

Check the admin status of the interfaces on the NSX Logical Router.

EdgeInterfacesDownEvent

LogicalRouter

1.0

vRNI-One or more Fabric Nodes are added as standalone hosts in NSX-T. Virtual Machines on those hosts will not be visible in vRNI.

Add the vCenter server managing the standalone hosts as a Compute Manager on NSX-T Manager.

NSXTStandaloneHostsEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Number of members in application exceeds supported limit

Reduce number of members in the application.

ArkinApplicationMemberLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Nodes Version Mismatch detected

NODES_VERSION_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Node Statistics Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNodeStatsStatusEvent.recommendation-0.

NSXTMPNodeServiceNodeStatsStatusEvent

ManagementNode

1.0

vRNI-All NSX Edges in the ECMP Cluster are currently down, which is preventing upstream communication

  1. Verify that the VM for each NSX Edge is running.

  2. Verify that the VM for each NSX Edge is connected to the network.

NSXAllEcmpEdgesDownEvent

EdgeServicesGateway

1.0

vRNI-NSX-T Edge Node Tunnel Status is 'Down'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTEdgeNodeTunnelStatusDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when BGP status is Down.

HybridConnectBgpStatusDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more essential services are not healthy.

NOT_ALL_SERVICES_HEALTHY_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Memory usage of analytics process has exceeded maximum allocated limit. Please follow resolution steps to re-enable processing

ANALYTICS_MEMORY_LIMITS_EXCEEDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Webhook is not running on the Collector(Proxy) VM

WEBHOOK_NOT_RUNNING_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-AWS Security Groups available with AWS Region.

AWSRegionSGLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSXT IPFIX No Ipfix Profile

NSXT_IPFIX_NO_IPFIX_PROFILE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-More than 90% of VXLAN segment IDs have been used

Add additional logical segment IDs to the NSX transport zone.

VxLanRangeExhaustEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more OSPF areas on the NSX Edge Services Gateway or DLR are not configured to use MD5 authentication, which could compromise information about the network

Configure the NSX logical router to use MD5 authentication for all OSPF areas.

OspfInsecureAuthRouterEvent

LogicalRouter

1.0

vRNI-Unknown Host

UNKNOWN_HOST_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Number of applications in ServiceNow exceeds NI system limit.

SERVICE_NOW_APP_LIMIT_EXCEEDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The SpoofGuard configuration was not applied to the specified vNIC on the host.

  1. Verify that the host preparation procedure was followed.

  2. Log in to the host and collect the /var/log/vsfwd.log file and then force sync the firewall configuration with the API https://{nsx-mgr}/api/4.0/firewall/forceSync/{host-id} (see 'Troubleshooting Distributed Firewall' in the NSX Troubleshooting Guide).

  3. If the SpoofGuard configuration still fails, collect the NSX Manager and host tech support logs, and contact VMware support.

SpoofguardApplyToVnicFailedEvent

VirtualMachine

1.0

vRNI-Underlay device temperature threshold exceeded event.

Check the specific sensor on underlay device.

UnderlayDeviceTemperatureThresholdExceededEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Both VMs of Edge HA are in active state. The most common issue is split-brain, caused by underlying network connectivity loss.

  1. Execute the 'show service highavailability' command on all controller nodes and look at the Highavailability Status, Highavailability Healthcheck Status (BFD state) and Config Engine Status.

  2. Check for network connectivity issues using ping or by capturing packets on the HA interface.

  3. Use the 'debug packet display interface &ltha_interface&gt port_3794' command as the Edge HA implementation uses BFD uses and UDP port 3794. If the Edge is in an unrecoverable state, reboot the Edge.

NSXEdgeSplitBrainEvent

EdgeServicesGateway

1.0

vRNI-Appliance certificate expired.

REG_CERT_EXPIRED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-No syslog server is configured for the NSX Controller. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration

Configure syslog server for NSX Controller.

ControllerSysLogServerEvent

Controller

1.0

vRNI-NSX-T Host Node has lost manager connectivity.

NSXTHostNodeMgmtConnectivityStatusDownEvent

TransportNode

1.0

vRNI-Policy Service status has turned to stopped.

EventInfo.NSXTMPNodeServicePolicyStatusEvent.recommendation-0.

NSXTMPNodeServicePolicyStatusEvent

ManagementNode

1.0

vRNI-NSXT IPFIX no new Collector Profile can be added

NSXT_IPFIX_NO_NEW_COLLECTOR_PROFILE_CAN_BE_ADDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A distributed firewall rule was not applied to a host's vNIC.

  1. Check if vsfwd process is running on the specified Host.

  2. Verify that the vsip kernel heaps have enough free memory.

  3. If problem still persist, please collect ESXi and NSX Manager tech support bundle and open a SR with VMware technical support.

ApplyRuleToVnicFailedEvent

VirtualMachine

1.0

vRNI-Transmitted packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster.

Check the state and MTU of specified interface.

NSXTTxPacketDropOnMPNicEvent

ManagementNode

1.0

vRNI-One or more NSX Edges in the ECMP Cluster are currently down, which has degraded the capacity of the cluster

  1. Verify that the VM for each NSX Edge is running.

  2. Verify that the VM for each NSX Edge is connected to the network.

NSXEcmpEdgeDownEvent

EdgeServicesGateway

1.0

vRNI-VeloCloud Edge Degraded Voice QOE Event.

Verify that the Edge is in healthy state.

VeloCloudEdgeDegradedVoiceQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-An update to the SpoofGuard configuration failed for the host.

  1. Check if the vsfwd process is running on the Host and the network connection is established between it and NSX Manager.

  2. Use CLI commands to verify if the rule realization is working properly or not on the affected Host.

  3. If the problem persists, please collect ESXi and NSX Manager tech support bundles and open an SR with VMware technical support.

  4. See also 'Troubleshooting Distributed Firewall' in the NSX Troubleshooting Guide.

SpoofguardConfigUpdateOnHostFailedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The Latency Node Group configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T.

NSXT_LATENCY_NODE_GROUP_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Tunnel Status is 'Down'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTHostNodeTunnelStatusDownEvent

TransportNode

1.0

vRNI-This event is raised when the number of VMs in a VMC SDDC exceeds limits.

  1. Delete VMs that are not in use.

  2. Deploy a new VMC SDDC.

VMCVMLimitExceededEvent

VMwareAdapter

1.0

vRNI-Transmitted packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host.

Check the state and MTU of specified interface.

NSXTTxPacketDropOnHostTnNicEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more DLR networks cannot be reached from the uplink interface on the NSX Edge router. This condition suggests either an OSPF configuration error on the Edge-router/DLR or route not configured on uplink router.

  1. Check the routes on the router connected to the uplink of the NSX Edge router.

  2. Route to reach the distributed logical router should exist on the router connected to the uplink of the NSX Edge router.

DLRNetworksNotReachableEvent

LogicalRouter

1.0

vRNI-AWS Flow Log Access Denied Exception. This event is raised when user does not have necessary permissions required to collect flow logs.

AWS_FLOW_LOG_ACCESS_DENIED_EXCEPTION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Permitted VLANs in underlay trunk switch ports do not match

Ensure that the allowed VLANs in both the trunk ports match.

UnderlayPortTrunkMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Tunnel Status is 'Unknown'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTEdgeNodeTunnelStatusUnknownEvent

TransportNode

1.0

vRNI-NSX-T management node has lost management cluster connectivity.

Check if the node has proper network connectivity with management cluster.

NSXTMPNodeToMgmtClusterConnectivityEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The version of NIOS is not supported.

UNSUPPORTED_INFOBLOX_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Error connecting to data source

CONNECTION_ERROR_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Invalid Data Source Config

WARN_CONFIG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A configuration update pushed to hosts over the NSX messaging channel did not complete.

  1. Check if the vsfwd process is running on the Host.

  2. Check if the network connection is established between vsfwd process on the Host and the NSX Manager.

  3. See also <a target.

HostMessagingConfigurationFailedEvent

HostSystem

1.0

vRNI-An NSX Edge has failed to deploy. This condition may indicate that an NSX Edge has been configured without actually being deployed.

  1. Check for errors that occurred during deployment of the NSX Edge.

  2. Redeploy the NSX Edge.

EdgeNotDeployedEvent

EdgeServicesGateway

1.0

vRNI-The distributed firewall rule table differs between the host and NSX Manager.

  1. Check the message-bus connection between the host (the vsfwd daemon or messaging agent) and NSX Manager.

  2. See also <a target.

HostWithStaleFirewallRulesEvent

HostSystem

1.0

vRNI-There is no syslog server configured on the NSX Manager. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration

Configure Syslog Server for NSX Manager.

NSXSysLogServerEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NTP Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNTPStatusEvent.recommendation-0.

NSXTMPNodeServiceNTPStatusEvent

ManagementNode

1.0

vRNI-An NSX management appliance service is down

  1. The NSX management service must be running. To enable the stopped service, open the NSX Manager appliance GUI and check the Summary tab.

  2. See also <a target.

NSXComponentEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Invalid SNMP Connection

SNMP_CONNECTION_INVALID_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-High Availability is not enabled on the NSX Edge, which may impact network availability.

  1. Enable high availability on the NSX Edge.

  2. See 'About High Availability' in the NSX Administration Guide.

EdgeHANotConfiguredEvent

EdgeServicesGateway

1.0

vRNI-Upgrade Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNSXUpgradeAgentStatusEvent.recommendation-0.

NSXTMPNodeServiceNSXUpgradeAgentStatusEvent

ManagementNode

1.0

vRNI-Event reported by kubernetes cluster

KubernetesBaseEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T controller node has lost control cluster connectivity.

Check if the node has proper network connectivity with control cluster.

NSXTControllerNodeToControlClusterConnectivityEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Disk Cleanup service is unhealthy.

DISK_CLEANUP_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-vRealize Network Insight Content Pack not found in Log Insight

vRNI_CONTENT_PACK_NOT_INSTALLED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when pool member of load balancer is down. To know the pool members which are down, search 'Pool Member where state

  1. Ensure that pool member has not been disabled by the administrator.

  2. Ensure that pool/pool-member uses the correct Health Monitors which are getting required responses from the backend server.

  3. Ensure that backend server used by this pool member is functional.

LBPoolMemberDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Connection Refused

CONNECTION_REFUSED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Network and security container information used with the NSX distributed firewall or with Service Composer failed to be updated on an NSX host.

  1. Check if vsfwd process is running on the specified Host.

  2. Verify that vsip module kernel heaps have enough free memory.

  3. Check VSFWD logs for any obvious error.

  4. If the problem still persists, collect ESXi and NSX Manager tech support bundles and open an SR with VMware technical support.

ContainerConfigUpdateOnVnicFailedEvent

VirtualMachine

1.0

vRNI-NSX-T Host Node Tunnel Status is 'Degraded'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTHostNodeTunnelStatusDegradedEvent

TransportNode

1.0

vRNI-Communication will be disrupted because Vlan on uplink port of Tier 0 router is different than Vlan on the external gateway.

Vlan is misconfigured on the tier-0 router. Make sure Vlan matches with the Vlan on the external gateway.

NSXTDoubleVlanTaggingEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Flow Collection Error

FLOW_COLLECTION_ERROR_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The distributed firewall is configured to allow all traffic by default, which increases the potential attack surface of the network

Configure the default firewall rule to block all traffic.

NSXFirewallDefaultAllowAllRulesEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Data Retention (Config Store Maintenance) service is unhealthy.

CONFIG_STORE_CLEANUP_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-There are fewer than three active controllers, which may cause provisioning operations to fail

  1. Verify that all NSX Controller VMs are powered on.

  2. Verify that all NSX Controller VMs are connected to the network. See also the 'NSX Controller' section in the NSX Troubleshooting Guide.

NSXControllerNotActiveCountEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Audit logs are currently excluded from backup, which could cause loss of security-related events

Enable backups of NSX Manager audit logs from the NSX Manager UI by going to Manage > Backup and Restore.

NSXBackupAuditLogExcludedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Underlay device event.

Check the underlay device.

UnderlayDeviceGenericEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when no NIC associated with IP of service node of load balancer is found

Ensure that VM which has IP of service node exist.

LBServiceNodeIPNotFoundEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when the number of Hosts per Cluster in a VMC SDDC exceeds limit.

Deploy a new Cluster in VMC SDDC.

VMCHostPerClusterLimitExceededEvent

ClusterComputeResource

1.0

vRNI-Password Authentication Mode Disabled for Arista

PWD_AUTH_MODE_DISABLED_ARISTA_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Pnic Status is 'Down'.

Please check if pNIC is properly connected.

NSXTHostNodePnicStatusDownEvent

TransportNode

1.0

vRNI-A threshold-crossing temperature detected on host FRUs.

ThresholdExceededEventDataSourceTemperature-0.

ThresholdExceededEventDataSourceTemperature

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Logical switch information between the primary NSX controller and all hosts where the logical switch is used does not match. This event may indicate an error condition is occurring after a sharding change.

  1. Confirm all NSX Controllers are accessible from the host, Confirm all the NSX Controllers are in active state and cluster majority is achieved.

  2. See 'Troubleshooting Controller Cluster' in the NSX Troubleshooting Guide.

HostNetworkControlPlaneMismatchEvent

HostSystem

1.0

vRNI-Mismatch in service appliance information between NSX Manager and Check Point.

  1. Check the state of the Check Point Service VM and ensure that it is booted properly.

  2. Confirm network connectivity exists between the Check Point Service VM and Check Point Management Serve.

  3. Confirm network connectivity exists between the Check Point Service VM and NSX Manager.

CheckpointNsxServiceApplianceViewMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Unsupported NSXT Version

UNSUPPORTED_NSXT_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-AWS Security Groups available with AWS Interface.

AWSInterfaceSGLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when virtual server of load balancer is disabled

To enable virtual server, open load balancer GUI and check virtual server state.

LBVirtualServerDisableEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The NSX feature version of the prepared cluster doesn't match with that of NSX Manager.

Execute 'Sync Logical Services' from the Installation screen.

ClusterFeatureVersionMismatchEvent

ClusterComputeResource

1.0

vRNI-CM Inventory Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceCmInventoryStatusEvent.recommendation-0.

NSXTMPNodeServiceCmInventoryStatusEvent

ManagementNode

1.0

vRNI-Collector VM configuration incomplete.

APPLIANCE_NOT_CONFIGURED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Appliance Disk not configured according to Disk Guidance.

DISK_ALLOCATION_INSUFFICIENT_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX Controller Not Found

NSX_CONTROLLER_NOT_FOUND_EVENT

VirtualMachine

1.0

vRNI-The MTU configured on one or more interfaces on the Edges in the same Layer 2 network does not match, which may impact network performance

Configure the same MTU on all Edge Interfaces which are in same Layer 2 network.

NSXEdgeMtuMismatchEvent

EdgeServicesGateway

1.0

vRNI-Panorama dynamic membership definition update from NSX Manager is delayed. This condition may indicate a network connectivity issue or an issue with NSX Manager's NetX service.

  1. Verify network connectivity exists between Panorama and the NSX Manager.

  2. Check if the Panorama is in registered state with NSX Manager.

  3. Manually synchronize the definition using 'Synchronize Dynamic Objects'.

PanNsxDynamicUpdateDelayedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The Latency Service Config configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T.

NSXT_LATENCY_SERVICE_CONFIG_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Roll-up Status is 'Unknown'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTHostNodeStatusUnknownEvent

TransportNode

1.0

vRNI-Router interafce is operationally down.

Check the operational status of the specified router interface.

RouterInterfaceOperationalDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A distributed firewall configuration update failed to be applied to a vNIC on an NSX prepared host.

  1. Check if the vsfwd process is running on the Host.

  2. Check if the network connection is established between the vsfwd process on the host and NSX Manager.

  3. If problem still persists, collect ESXi and NSX Manager tech support bundles and open an SR with VMware technical support.

FilterConfigApplyOnHostFailedEvent

HostSystem

1.0

vRNI-NSX-T Edge Node is not able to to communicate with one or more controllers.

NSXTControllerConnectivityDegradedEvent

TransportNode

1.0

vRNI-The number of records from Infoblox exceeds current limit

INFOBLOX_RECORD_LIMIT_EXCEEDED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more Kubernetes Cluster Service Accounts do not have sufficient privileges.

KUBERNETES_INSUFFICIENT_PRIVILEGES_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Migration Co-ordinator Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceMigrationCoordinatorStatusEvent.recommendation-0.

NSXTMPNodeServiceMigrationCoordinatorStatusEvent

ManagementNode

1.0

vRNI-The message bus and/or control plane agent daemon on this Host is experiencing connection failures with NSX Controller or NSX Manager

  1. To check whether the message bus connection is established with NSX Manager, execute the 'esxcli network ip connection list | grep 5671' command and look for an ESTABLISHED state. To check whether the control plane connection is established between the host's control plane agent and the NSX Controller, execute the 'esxcli network ip connection list | grep 1234' command.

  2. Note - the control plane agent on a host will not connect to controllers unless there is a need to fetch some information from the controller.

ModuleNetworkConnectionFailureEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when multiple NICs associated with IP of service node of load balancer are found

Check if there are more than one VMs/VNICs with the IP address used in this service node.

LBServiceNodeMultipleNicFoundEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-SSH Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceSSHStatusEvent.recommendation-0.

NSXTMPNodeServiceSSHStatusEvent

ManagementNode

1.0

vRNI-Azure flow collection permissions or Azure flows not available

AZURE_FLOW_COLLECTION_ERROR_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Large SDMS Dropped, some information is not processed

LARGE_SDMS_DROPPED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The NSX distributed logical router control VM is deployed to the same host as one or more NSX Edges that are configured for ECMP.

Move the DLR control VM to a different host.

LogicalRouterDeployedOnEcmpEdgeHostEvent

LogicalRouter

1.0

vRNI-Invalid Response From Data Source

INVALID_RESPONSE_FROM_DATASOURCE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when the number of Clusters in a VMC SDDC exceeds limits.

Deploy a new VMC SDDC.

VMCClusterLimitExceededEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Recent data is still being indexed. Search results may be inaccurate.

INDEXER_LAG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-No access to shell for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility.

BIGIP_INSUFFICIENT_SHELL_ACCESS_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Unexpected Datasource Type or Version

UNEXPECTED_DS_TYPE_OR_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Updated information on the host messaging channel failed to be sent to the NSX host.

  1. Check if the vsfwd process is running on the Host

  2. Check if the network connection is established between vsfwd process on the Host and the NSX Manager

  3. See also <a target.

HostMessagingConnectionReconfigurationFailedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A distributed firewall rule is masked by one or more preceding rules. This condition may indicate a configuration error, such as a redundant rule.

Validate the modification was expected. If not planned or expected, configure the required firewall rule(s).

FirewallRuleMaskEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-DataStore Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceDataStoreStatusEvent.recommendation-0.

NSXTMPNodeServiceDataStoreStatusEvent

ManagementNode

1.0

vRNI-VeloCloud Link Degraded Video QOE Event.

Verify that the Link is in healthy state.

VeloCloudLinkDegradedVideoQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The version of NIOS cannot be determined.

UNKNOWN_INFOBLOX_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-SMTP Not Configured

SMTP_NOT_CONFIGURED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Management Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceMgmtPlaneBusStatusEvent.recommendation-0.

NSXTMPNodeServiceMgmtPlaneBusStatusEvent

ManagementNode

1.0

vRNI-Transmitted packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster.

Check the state and MTU of specified interface.

NSXTTxPacketDropOnEdgeTnNicEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-VeloCloud Link Degraded Transactional QOE Event.

Verify that the Link is in healthy state.

VeloCloudLinkDegradedTransQoeEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Host Node Roll-up Status is 'Down'.

Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node.

NSXTHostNodeStatusDownEvent

TransportNode

1.0

vRNI-An infrastructure VM is experiencing a high memory condition. This condition may lead to an NSX service disruption.

Check the memory resource allocated to the specified VM. Allocate more memory if required.

ServiceVMHighMemoryUsageEvent

VirtualMachine

1.0

vRNI-An NSX infrastructure VM is experiencing high CPU. This condition may lead to a service disruption.

Check the underlying Host for resource usage. Migrate some of the VMs to other Hosts.

ServiceVMHighCPUUsageEvent

VirtualMachine

1.0

vRNI-Underlay device LLDP neighbour removed event.

Check the LLDP neighbour details on underlay device.

UnderlayDeviceLldpNeighbourRemovedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-User defined Problem when search result changes

SearchStreamMembershipProblemEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Compute Managers Not Found

COMPUTE_MANAGERS_NOT_FOUND_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Indexing Aborted

INDEXING_ABORTED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-MTU setting of underlay switch ports do not match

Ensure that the MTU setting on both the ports match.

UnderlayMtuMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Last data collection on data source was more than 30 minutes ago

COLLECTION_LAG_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Communication failure detected between NSX Manager and Edge VM.

  1. Check if the NSX Edge VM is in powered on state. If not, then power it on.

  2. Check if NSX Edge and NSX Manager are reachable from each other.

  3. If problem still persist, please collect NSX Manager tech support bundle and open a SR with VMware technical support.

  4. See also 'NSX Manager and Edge Communication Issues' in the Edge Appliance Troubleshooting section of the NSX Troubleshooting Guide.

EdgeVMCommunicationFailureEvent

LogicalRouter

1.0

vRNI-Unsupported NSX Version

UNSUPPORTED_NSX_VERSION_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX IPFIX Status Mismatch

NSX_IPFIX_STATUS_MISMATCH_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Logical Port Operational Status is 'Down'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another.

NSXTLogicalPortOperationalStatusDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Duplicate IP Address found on multiple ports

Ensure that the ports have unique IP addresses.

UnderlayDuplicateIPAddressEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when VM associated with pool member of load balancer is down

Check if VM associated with pool member is powered on and running.

LBPoolMemberVMDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-DFW IPFIX Profile is not found on NSX Policy Manager

POLICY_MANAGER_NO_DFW_IPFIX_PROFILE

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of buffer usage have been detected on a router interface.

Check the traffic on specified router interface.

RouterInterfaceBufferThresholdExceededEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Loop detected in forwarding path

Update device configuration to eliminate loop.

LoopDetectionEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more essential services are not running.

NOT_ALL_SERVICES_RUNNING_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-The MTU configured on interface(s) of Tier-0 logical router do not match with the interface(s) of uplink switch/router from same L2 network. This may impact network performance.

Configure same MTU on interfaces between Tier-0 logical router and uplink routers.

NSXTMtuMismatchEvent

EdgeServicesGateway

1.0

vRNI-VeloCloud Link Packet Loss Event Tx.

Verify that the Link is in healthy state.

VeloCloudLinkLostPacketEventTx

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Edge State of VeloCloud Edge is not connected.

Verify that the VeloCloud Edge is UP.

VeloCloudEdgeDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-AWS Security Groups available with AWS VPC.

AWSVPCSGLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Network Insight IPFIX Collector IP and port are not present in DFW IPFIX Collector Profile on NSX Policy Manager.

POLICY_MANAGER_VRNI_DFW_IPFIX_COLLECTOR_ABSENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Search Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceSearchStatusEvent.recommendation-0.

NSXTMPNodeServiceSearchStatusEvent

ManagementNode

1.0

vRNI-A threshold-crossing amount of packet drops have been detected on the specified device.

Check the state and MTU of specified interface

DevicePacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of packet drops have been detected on the switch port associated with the specified physical NIC.

Check the state and MTU of the specified switch port.

PnicUnderlyingSwitchPortPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-An NSX Edge VM is not responding to health check by NSX Manager

  1. Check if the NSX Edge VM is in powered on state. If not, then power it on.

  2. Check if NSX Edge and NSX Manager are reachable from each other.

  3. If the problem persists, collect the NSX Manager tech support bundle and open an SR with VMware technical support.

EdgeVMNotRespondingEvent

LogicalRouter

1.0

vRNI-NSXT IPFIX No Collector Profile

NSXT_IPFIX_NO_COLLECTOR_PROFILE_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node Tunnel Status is 'Degraded'.

Please check the status of the tunnel interfaces for this NSX-T Transport Node.

NSXTEdgeNodeTunnelStatusDegradedEvent

TransportNode

1.0

vRNI-Message Bus Client Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceNSXMessageBusStatusEvent.recommendation-0.

NSXTMPNodeServiceNSXMessageBusStatusEvent

ManagementNode

1.0

vRNI-Failed to expand disk partition.

EXPAND_PARTITION_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Received packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host.

Check the state and MTU of specified interface.

NSXTRxPacketDropOnHostTnNicEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-One or more BGP neighbours are not in established state.

NSXEdgeBGPNeighbourDownEvent

EdgeServicesGateway

1.0

vRNI-Hardware Gateway Binding Switch Port is down

EventInfo.HardwareVTEPPortDownEvent.recommendation-0.

HardwareVTEPPortDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing amount of packet drops have been detected on a VM interface.

Check the state and MTU of the specified Virtual Machine interface.

VnicPacketDropEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-An MTU mismatch was found in the path between a VTEP and its physical switch port

  1. Configure the same MTU value for physical NICs between the specified VTEP and its physical switch port.

  2. Check jumbo frame support along the path.

MTUMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-CM Inventory Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceClusterManagerStatusEvent.recommendation-0.

NSXTMPNodeServiceClusterManagerStatusEvent

ManagementNode

1.0

vRNI-Port duplex setting of underlay switch ports do not match

Ensure that the duplex setting of both the ports match.

UnderlayDuplexMismatchEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Two or more messaging-channel heartbeat messages between NSX Manager and an NSX host were missed.

  1. Check if the vsfwd process is running on the Host.

  2. Check if the network connection is established between vsfwd process on the Host and the NSX Manager.

  3. See also <a target.

HostMessagingInfrastructureDownEvent

HostSystem

1.0

vRNI-NSX Manager backups are not configured. Proper backup of all NSX components is crucial to restore the system to its working state in the event of a failure

  1. Configure scheduled backups for NSX.

  2. For configuration assistance, refer to the 'NSX Backup and Restore' section in the NSX Administration Guide.

  3. NOTE - the only supported backup is via Manager.

NSXBackupEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-VXLAN does not have an uplink on specified Host

Assign proper uplink for specified layer2 network.

L2NetworkUplinkMissingEvent

TransportNode

1.0

vRNI-Inbound Rules available with AWS Security Group.

AWSSGInboundRuleLimitEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-A threshold-crossing CPU usage detected on host FRUs.

ThresholdExceededEventDataSourceCpuUsage-0.

ThresholdExceededEventDataSourceCpuUsage

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Credential Encryption Failed

FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-This event is raised when pool of load balancer is down

Ensure that pool has at least one functional pool member.

LBPoolDownEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Most of the allocated disk space for an infrastructure VM has been consumed. The infrastructure VM may become inaccessible or lead to a service disruption.

  1. Clean up the disk.

  2. Allocate more disk space if required.

ServiceVMHighDiskUsageEvent

VirtualMachine

1.0

vRNI-Install Upgrade Service status has turned to stopped.

EventInfo.NSXTMPNodeServiceInstallUpgradeEvent.recommendation-0.

NSXTMPNodeServiceInstallUpgradeEvent

ManagementNode

1.0

vRNI-A Check Point' security appliance VM was not found on a host in an NSX prepared cluster.

Check the state of the Check Point Service VM on the specified host. Ensure that it is booted properly.

CheckpointNsxServiceVMNotFoundOnHostEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-Data Retention (Metric Store Maintenance) service is unhealthy.

METRIC_STORE_UPDATER_FAILED_EVENT

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T has a Compute Manager which is not added as a data source in vRNI.

Check if the Compute Manager registered in NSX-T Manager is also added as a data source in vRNI.

NSXTVcNotAddedEvent

NETWORK_INSIGHT_OTHERS

1.0

vRNI-NSX-T Edge Node is not able to communicate with any of the controllers.

NSXTControllerConnectivityDownEvent

TransportNode

1.0

vRNI-Underlay device fan removed or not working event.

Check the specific fan on underlay device.

UnderlayDeviceFanMalFunctionEvent

NETWORK_INSIGHT_OTHERS