The vRealize Network Insight adapter integrates alerts that are unknown to vRealize Operations Manager. These alerts are added to vRNI Alerts. You can enable or disable the generation of alerts on vRNI Alerts using the VRNI_IS_ALERTS_ON_VRNI_AlERTS_ENABLED
property. To do so, stop the adapter instance, make the property changes on all the nodes, and start the adapter instance.
This Management packs gathers information on the inventory of the data sources configured in vRealize Network Insight. These data sources must be configured as end points in vRealize Operations Manager.
From the Alerts tab or from the Inventory, you can troubleshoot issues by getting the insights of object on which the alert is triggered by using launch-in-context to vRealize Network Insight.
For the alerts or notifications without any object mapping in the inventory, you can launch-in-context to either problems or user defined events of vRealize Network Insight.
In the Inventory, the launch-in-context option is available only for the following objects:
End Point |
Object |
---|---|
vCenter |
|
NSX for vSphere |
|
VRealize Network Insight |
|
VRNI_USER_DEFINED_EVENT_OVERLAP_IN_HOURS
property in
NetworkInsight.properties
.
Alert Definition |
Recommendations |
Event ID |
Resource Kind |
MP Version |
---|---|---|---|---|
vRNI-Security Fabric Agent not reported by NSX for a Host which belongs to a prepared cluster |
|
CheckpointNsxFabricAgentNotFoundOnHostEvent |
HostSystem |
1.0 |
vRNI-Compute Managers Not Added |
COMPUTE_MANAGERS_NOT_ADDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A distributed firewall ruleset was not applied to a host. |
|
RulesetLoadOnHostFailedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-All VTEPs are deleted from the transport node. VMs might lose connectivity because of this. |
Make sure VTEPs/Vmknics are not deleted from the transport node. |
NSXTVtepDeleteEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Logical Switch Admin Status is 'Down'. |
Please enable the NSX-T Logical Switch Admin Status in NSX-T. |
NSXTLogicalSwitchAdminStatusDownEvent |
LogicalSwitch |
1.0 |
vRNI-Latency collection was disabled in the NSX-T Manager after it was enabled by Network Insight. As a result, Network Insight is not receiving latency information from the NSX-T. |
NSXT_LATENCY_NOT_ENABLED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Unable to send email message. |
UNABLE_TO_SEND_EMAILS_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T controller node has lost management plane connectivity. |
Check if the node has proper network connectivity with management plane. |
NSXTControllerNodeToMgmtPlaneConnectivityEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-SNMP Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceSNMPStatusEvent.recommendation-0. |
NSXTMPNodeServiceSNMPStatusEvent |
ManagementNode |
1.0 |
vRNI-vCenter managing one or more fabric nodes in NSX-T is not added as a data source in vRNI. Virtual Machines on those hosts will not be visible in vRNI. |
Add the vCenter server managing the standalone hosts as a datasource into vRNI. |
NSXTStandaloneHostsEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Flow processing suspended |
FLOW_PROCESSING_SUSPENDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Considerable count of packet drops detected at specified switch port |
Check the state and MTU of specified switch port. |
SwitchPortPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Retransmitted Packet Event on Edge for Application. |
Verify that the Link is in healthy state. |
VeloCloudEdgeL7ApplicationRetransmittedPacketEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Host Node Tunnel Status is 'Unknown'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTHostNodeTunnelStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-Not Empty Node |
NOT_EMPTY_NODE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Infoblox credentials are invalid or the user does not have the "API Privilege" to access Infoblox data |
INCORRECT_INFOBLOX_CREDENTIAL_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Hardware Gateway Bindings Mismatch between NSX and switch |
EventInfo.HardwareVTEPMismatchEvent.recommendation-0. |
HardwareVTEPMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The NSX infrastructure VM found to be in powered off state. Services provided by it may get impacted. The NSX infrastructure includes Controller cluster, NSX Manager, and one or more Edge VMs. |
|
ServiceVMNotPoweredOnEvent |
VirtualMachine |
1.0 |
vRNI-vRealize Network Insight Content Pack version not supported |
UNSUPPORTED_vRNI_CONTENT_PACK_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Edge Node Roll-up Status is 'Unknown'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTEdgeNodeStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-Underlay device module removed or not working event. |
Check the specific module on underlay device. |
UnderlayDeviceModuleMalFunctionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Edge Node Pnic Status is 'Down'. |
Please check if all the pNICs are properly connected. |
NSXTEdgeNodePnicStatusDownEvent |
TransportNode |
1.0 |
vRNI-Underlay device power supply removed or not working event. |
Check the specific power supply on underlay device. |
UnderlayDevicePsMalFunctionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-At least one of NSX VIB or host module was not detected on the host, and NSX operations may be affected. The VIB or module may have been unloaded manually by error. |
|
ModuleNotLoadedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more host VTEPs' IP addresses are not on the same subnet as other VTEPs in the same cluster. This condition may result in network connectivity issues |
Assign the same IP subnet to all hosts in the cluster. You can use either DHCP or manually configured IP pools for VTEP IP addresses. See 'Configure VXLAN Transport Parameters' in the NSX Installation Guide. |
VtepSubnetMismatchEvent |
ClusterComputeResource |
1.0 |
vRNI-Collector Port in Collector Profile is incorrect |
NSXT_IPFIX_PORT_INCORRECT_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Invalid Credentials |
INVALID_CREDENTIALS_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The host's fabric status resource feature version is not same as that of the cluster or NSX Manager |
Check if the host is in connected state and can connect to NSX Manager. |
HostFeatureVersionMismatchEvent |
HostSystem |
1.0 |
vRNI-Ipfix Flow Data Source has been paused due to large number of flows. |
IPFIX_FLOW_DP_PAUSED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-No SNMP Targets are configured. |
SNMP_NOT_CONFIGURED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Underlay device BFD session deleted event. |
Check the BFD details on underlay device. |
UnderlayDeviceBfdSessionRemovedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A service VM or gateway for Check Point does not have 'communicating' SIC status |
Check that SIC is established with the Security gateway. Access the gateway object in SmartDashboard and confirm the SIC status. |
CheckpointGatewaySicStatusNotCommunicatingEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The host's VTEP count doesn't match the VTEP count of other hosts in the same cluster. VMs on this host connected to a logical switch may not be able to communicate. |
|
VtepCountMismatchEvent |
ClusterComputeResource |
1.0 |
vRNI-Invalid Data Source Config |
INVALID_CONFIG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-One or more networks connected to an NSX Edge router are not reachable from an uplink router. |
|
EdgeNetworksNotReachableEvent |
LogicalRouter |
1.0 |
vRNI-A threshold-crossing memory usage detected on host FRUs. |
ThresholdExceededEventDataSourceMemoryUsage-0. |
ThresholdExceededEventDataSourceMemoryUsage |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Host Not Reachable |
HOST_NOT_REACHABLE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Flow Physical Node |
FLOW_PHYSICAL_NODE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Node Management Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNodeMgmtStatusEvent.recommendation-0. |
NSXTMPNodeServiceNodeMgmtStatusEvent |
ManagementNode |
1.0 |
vRNI-File required by Generic Routers & Switches Data Source does not exist |
UANI_FILE_DOES_NOT_EXIST_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The data source identity information such as certificate or the key has changed. |
DATASOURCE_IDENTIFICATION_CHANGED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A threshold-crossing amount of transmit-side packet drops have been detected on a host interface. |
Check the state and MTU of the affected Host's interface. |
ThresholdExceededEventNetworkTxDropRule |
HostSystem |
1.0 |
vRNI-Event generated as a result of the specified metric crosses the upper or lower bound specified in the configuration |
AnalyticsThresholdEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Network Insight does not support the IPFIX flow data from NSX-T Switches. It is configured to send IPFIX data to one of the Network Insight Collector VM. It may have corrupted existing flow data in the system. |
Remove Network Insight Collector VM IP Address from the NSX-T Switch collector profiles which are used in NSX-T Switch IPFIX profiles. |
NSXTSwitchIpfixEnabledEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Tier-1 logical router is disconnected from Tier-0 router. Networks under this router are not reachable from outside and vice versa. |
Connect Tier-1 Logical Router to Tier-0 Logical Router. |
NSXTNoUplinkConnectivityEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Network Insight Collector VM is not receiving network latency metrics from host |
|
NSXVLatencyNoDataEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Fex fan removed or not working event. |
Check the specific fan on fex device. |
UnderlayDeviceFexFanMalFunctionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Edge Node Roll-up Status is 'Degraded'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTEdgeNodeStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-NSX-T IPFIX DFW is not Enabled |
NSXT_IPFIX_DFW_STATUS_NOT_ENABLED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Mismatch in service appliance information between NSX Manager and Panorama. |
|
PanNsxServiceApplianceViewMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Webhook not enabled for one or more alerts of vRealize Network Insight Content Pack in Log Insight |
WEBHOOK_NOT_ENABLED_ON_ALERT_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Link State of VeloCloud Edge is not connected. |
Verify that the VeloCloud Link is UP. |
VeloCloudLinkDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The VTEP MTU does not match between a host and the NSX prepared cluster. |
Check the MTU of all the VTEPs of hosts in the cluster. To change the MTU settings of deployed VXLAN port groups via the NSX API, please refer <a target. |
ClusterHostsVtepMTUMismatchEvent |
ClusterComputeResource |
1.0 |
vRNI-Scheduled backups of the environment have not been configured |
Configure scheduled backups for NSX Manager. See also 'NSX Backup and Restore' in the NSX Administration Guide. |
NSXBackupNotScheduledEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Node Not Active |
NODE_NOT_ACTIVE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSXT IPFIX Collector and Ipfix Profile Mismatch |
NSXT_IPFIX_COLLECTOR_AND_IPFIX_PROFILE_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX Manager and the associated vCenter DataSources is not on the same Collector VM. |
VC_NOT_ON_SAME_PROXY_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Syslog Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceSyslogStatusEvent.recommendation-0. |
NSXTMPNodeServiceSyslogStatusEvent |
ManagementNode |
1.0 |
vRNI-VeloCloud Link Packet Loss Event Rx. |
Verify that the Link is in healthy state. |
VeloCloudLinkLostPacketEventRx |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Received packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected. |
Check if there is MTU mismatch on the connected ports or any firewall rule is responsible for dropping of received packets. |
NSXTLogicalSwitchReceivedPacketDropEvent |
LogicalSwitch |
1.0 |
vRNI-Panorama is not in a registered state with NSX Manager. |
Check network connectivity between Panorama and the NSX Manager. |
PanNsxNotInRegisteredStateEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-HTTP Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceHttpStatusEvent.recommendation-0. |
NSXTMPNodeServiceHttpStatusEvent |
ManagementNode |
1.0 |
vRNI-The network fabric feature status for a host does not match the status of other hosts in the cluster. |
Check if the Host is in connected state and can connect to NSX Manager. For more information, please see the 'Host Preparation' section in the NSX Troubleshooting Guide. |
HostFeatureInstalledMismatchEvent |
HostSystem |
1.0 |
vRNI-Primary NSX Not Added |
PRIMARY_NSX_NOT_ADDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-OSPF is enabled on the NSX Edge, but Interface to OSPF area mapping configuration is missing |
Configure the OSPF to interface area mapping for the specified NSX Edge interface. |
EdgeMissingInterfaceOSPFAreaMappingEvent |
EdgeServicesGateway |
1.0 |
vRNI-NSX-T Host Node Roll-up Status is 'Degraded'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTHostNodeStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-NSX-T Edge Node has lost manager connectivity. |
NSXTManagerConnectivityDownEvent |
TransportNode |
1.0 |
|
vRNI-NSX-T Host Node Pnic Status is 'Degraded'. |
Please check if pNIC is properly connected. |
NSXTHostNodePnicStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-There are fewer than three controllers deployed, which increases the risk of an outage when a controller is down. Or even number of NSX Controllers are found to be deployed, which may cause the split brain and disrupt network connectivity |
|
NSXControllersDeployedCountEvent |
ControllerCluster |
1.0 |
vRNI-Host with Infrastructure VMs cannot be accessed |
|
CriticalHostNotAccessibleEvent |
HostSystem |
1.0 |
vRNI-Incorrect Connection String |
INCORRECT_CONNECTION_STRING_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Telemetry Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceTelemetryStatusEvent.recommendation-0. |
NSXTMPNodeServiceTelemetryStatusEvent |
ManagementNode |
1.0 |
vRNI-Upgrade Failed |
UPGRADE_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Data Source Failed |
FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Received packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. |
Check the state and MTU of specified interface. |
NSXTRxPacketDropOnEdgeTnNicEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-UI Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceUIServiceStatusEvent.recommendation-0. |
NSXTMPNodeServiceUIServiceStatusEvent |
ManagementNode |
1.0 |
vRNI-A host in a cluster prepared for NSX is missing at least one VTEP. VMs on this host connected to any logical switch may not be able to communicate. |
|
HostVtepNotFoundEvent |
HostSystem |
1.0 |
vRNI-Alarm/Event generated by NSX-T platform |
NSXTSystemEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-AWS Throttling Exception |
AWS_THROTTLING_EXCEPTION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Edge Node Pnic Status is 'Degraded'. |
Please check if all the pNICs are properly connected. |
NSXTEdgeNodePnicStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-Not Found |
NOT_FOUND_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Duplicate MAC Address found on multiple ports |
Ensure that the ports have unique MAC addresses. |
UnderlayDuplicateMacAddressEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Controller Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceControllerStatusEvent.recommendation-0. |
NSXTMPNodeServiceControllerStatusEvent |
ManagementNode |
1.0 |
vRNI-This event is raised when the number of VMs per Host in a VMC SDDC exceeds limits. |
|
VMCVMPerHostLimitExceededEvent |
HostSystem |
1.0 |
vRNI-An IPSet with the same name and different scopes is defined in two NSX Managers. This condition may indicate a configuration error. |
Check the specified IPSet's definition in all NSX Managers. |
IPSetDefinitionMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Log Insight version not supported |
UNSUPPORTED_LOG_INSIGHT_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The VXLAN segment ID ranges defined in different NSX Managers have overlapping ranges, which is not a VMware best practice. |
|
SegmentMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-VeloCloud Edge Degraded Video QOE Event. |
Verify that the Edge is in healthy state. |
VeloCloudEdgeDegradedVideoQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX Edge VM is reporting a problematic state and might not be functioning correctly. |
|
EdgeUnhealthyEvent |
EdgeServicesGateway |
1.0 |
vRNI-Data Retention (Metric Retention Configuration) service is unhealthy. |
HBASE_RETENTION_TOOL_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-This event is raised when any system protection limit is exceeded |
PROTECTION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The Latency Stat profile configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. |
NSXT_LATENCY_STAT_PROFILE_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The installed NSX feature is reported for some problem by NSX Manager. |
Check the specified NSX feature installation status on the NSX UI and then sync the specified feature. |
FeatureUnhealthyEvent |
HostSystem |
1.0 |
vRNI-Data Source Timeout |
TIMEOUT_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Outbound Rules available with AWS Security Group. |
AWSSGOutboundRuleLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Routing advertisement is disabled for NSX-T Tier-1 logical router. Networks under this router are not reachable from outside. |
Enable route advertisement on Tier-1 logical router. |
NSXTRoutingAdvertisementEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-VeloCloud Edge Degraded Trans QOE Event. |
Verify that the Edge is in healthy state. |
VeloCloudEdgeDegradedTransQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-No transport zone attached to the transport node. VMs might lose connectivity because of this. |
Ensure that the transport node is attached to some transport zone. |
NSXTNoTzAttachedOnTnEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The OSPF area ID differs on connected router interfaces. |
Configure the same OSPF area ID for the DLR and Edge router interface mapping. |
OspfConfigurationMismatchEvent |
LogicalRouter |
1.0 |
vRNI-Appliance is not registered for online services. |
APPLIANCE_NOT_REGISTERED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-No NTP server is configured on the NSX Manager, likely impacting vCenter connectivity. The NTP server must be specified so that the SSO server time and NSX Manager time are in sync |
|
NSXNtpServerEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more OSPF neighbors connected to the NSX Edge are down, which may result in connectivity issues for virtual machines connected to this NSX Logical Router. |
|
NSXOspfNeighborDownEvent |
EdgeServicesGateway |
1.0 |
vRNI-A threshold-crossing amount of buffer usage have been detected on a switch port. |
Check the state and MTU of specified switch port. |
SwitchPortBufferThresholdExceededEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-When two Edge VMs have been configured for Edge high availability, this event indicates that one of the VMs is not powered on or both Edge VMs reside on the same host. |
|
EdgeNotHAEvent |
EdgeServicesGateway |
1.0 |
vRNI-NSX-T Logical Port Operational Status is 'Unknown'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. |
NSXTLogicalPortOperationalStatusUnknownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-FEX offline event. |
Check the specific fex on underlay device. |
UnderlayDeviceFexOfflineEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-User defined Problem when search result is empty |
EmptySearchStreamProblemEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Security Fabric Agent not reported by NSX for a Host which belongs to a prepared cluster |
|
PanNsxFabricAgentNotFoundOnHostEvent |
HostSystem |
1.0 |
vRNI-NSXT IPFIX Ipfix Profile Priority not zero |
NSXT_IPFIX_IPFIX_PROFILE_PRIORITY_NOT_ZERO_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Insufficient Role for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. |
BIGIP_INSUFFICIENT_ROLE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Same Switch or Router is added with different IPs. VM to VM path may not be generated. |
Delete duplicate Switches or Routers from Data Source. |
DuplicateL3SwitchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Considerable count of packets drop detected in VTEP underlay |
VTEPUnderlayPacketDropEvent-0. |
VTEPUnderlayPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when pool of load balancer is empty. To know pools which are empty, search 'Pool where PoolMembers Count |
Ensure that pool has at least one pool member. |
LBPoolEmptyEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A threshold-crossing amount of receive-side packet drops have been detected on a host interface. |
Check the state and MTU of the affected Host's interface. |
ThresholdExceededEventNetworkRxDropRule |
HostSystem |
1.0 |
vRNI-Last data collection on collector was more than threshold ago |
COLLECTOR_LAG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A firewall, NAT, load balancer, or VPN service is running on this NSX Edge with ECMP enabled |
Disable all Stateful Services (Firewall, NAT, Load Balancer, and VPN) on this NSX Edge. |
EcmpIsEnabledAndStatefulServicesAreUpEvent |
EdgeServicesGateway |
1.0 |
vRNI-Distributed Firewall is disabled in the NSX-T Manager. |
Please enable DFW Firewall from the NSX-T Manager. |
NSXTDFWFirewallDisabledEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Platform Client Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNSXPlatformClientStatusEvent.recommendation-0. |
NSXTMPNodeServiceNSXPlatformClientStatusEvent |
ManagementNode |
1.0 |
vRNI-Data Retention (Config Store Maintenance) service is not healthy. |
FDB_CONFIG_STORE_CLEANUP_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Up time is less than expected |
Check the operational status of the specified switch port. |
SwitchPortUptimeThresholdRecededEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Secure FTP is not currently being used for backups, which could compromise backup data |
|
NSXUnsecureBackupEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Assigned deployment definition is not matching the expected one. |
DEPLOYMENT_DEF_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Hostname Resolution Error |
HOSTNAME_RESOLUTION_ERROR_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Edge Node Pnic Status is 'Unknown'. |
Please check if all the pNICs are properly connected. |
NSXTEdgeNodePnicStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-NSX-T Manager backup is not scheduled. |
Configure scheduled backups for NSX-T from the NSX-T Manager. |
NSXTClusterBackUpDisabledEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Transmitted packets are getting dropped on the NSX-T Logical Port and associated entities might get affected. |
Check if there is MTU mismatch on the port or any firewall rule is responsible for dropping of transmitted packets. |
NSXTLogicalPortTransmittedPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Insufficient Partition Access for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. |
BIGIP_INSUFFICIENT_PARTITION_ACCESS_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The host's VTEP has been disabled and is in a not connected state. |
Check the connection state of VTEP vmknic on host. Go to Hosts and Clusters > host > Manage > Networking > Virtual Switches. |
HostVtepDisconnectedEvent |
HostSystem |
1.0 |
vRNI-All NSX Controllers in the cluster are deployed to the same host, which limits redundancy |
Move the NSX Controller VMs to different hosts. VMware recommends configuring a DRS anti-affinity rule to prevent the controllers from residing on the same host. |
NSXControllersVMOnSameHostEvent |
ControllerCluster |
1.0 |
vRNI-PostgreSQL Vacuum service is unhealthy. |
VACUUM_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A Palo Alto Networks' security appliance VM was not found on a host in an NSX prepared cluster. |
Check the state of the Palo Alto NGFW virtual machine on the specified host. Ensure that it is booted properly. |
PanNsxServiceVMNotFoundOnHostEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The collector configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. |
NSXT_LATENCY_COLLECTOR_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Azure Network Watcher permissions for fetching Storage Account IDs corresponding to Azure Network Security Group not available |
AZURE_NETWORK_WATCHER_STORAGE_ERROR_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Grid processing has stopped. |
GRID_PROCESSING_STOPPED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Liagent Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceLiagentStatusEvent.recommendation-0. |
NSXTMPNodeServiceLiagentStatusEvent |
ManagementNode |
1.0 |
vRNI-NSX System events with high or major severity |
Not Available. |
GenericNSXSystemEvent |
Manager |
1.0 |
vRNI-One or more VMs are not protected by NSX-T DFW firewall. Network Insight will not receive IPFIX flows for these VMs. |
Remove the relevant logical switches, logical ports or security groups from the NSX-T firewall exclusion list to enable flows. |
NSXTExcludedVmFlowEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Incorrect webhook configuration found for one or more alerts of vRealize Network Insight Content Pack in Log Insight |
INCORRECT_WEBHOOK_CONFIGURED_ON_ALERT_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Number of Vms or Hosts Not Found |
NUM_VMS_OR_HOSTS_NOT_FOUND_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Data is currently being re-indexed. Search service will be available after this migration activity is complete. |
REINDEXING_IN_PROGRESS_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T System Event API is taking longer than expected time to execute. |
NSXT_SYSTEM_EVENT_API_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Fex power supply removed or not working event. |
Check the specific power supply on fex device. |
UnderlayDeviceFexPsMalFunctionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Grid processing is lagging by more than threshold ago |
GRID_PROCESSING_LAG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-System events are currently excluded from backup, which could cause loss of security-related events |
Enable backups of NSX Manager system events from the NSX Manager UI by going to Manage > Backup and Restore. |
NSXBackupSystemEventsExcludedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Packet Drop Event on Edge for Application. |
Verify that the Link is in healthy state. |
VeloCloudEdgeL7ApplicationLostPacketEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-File required by Generic Routers & Switches Data Source not provided |
UANI_FILE_NOT_PROVIDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX System events with critical severity. |
Not Available. |
OtherCriticalNSXEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Received packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. |
Check the state and MTU of specified interface. |
NSXTRxPacketDropOnMPNicEvent |
ManagementNode |
1.0 |
vRNI-The NSX DLR is not configured with default route and may prevent external communication |
1.Check if the router configuration is only for routing between internal networks, or if external access is required. 2.If external access is required, then configure an uplink interface on the NSX distributed logical router. |
LogicalRouterNoUplinkEvent |
LogicalRouter |
1.0 |
vRNI-VeloCloud Link Degraded Voice QOE Event. |
Verify that the Link is in healthy state. |
VeloCloudLinkDegradedVoiceQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Insufficient Privileges |
INSUFFICIENT_PRIVILEGES_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Transmitted packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected. |
Check if there is MTU mismatch on the connected ports or any firewall rule is responsible for dropping of transmitted packets. |
NSXTLogicalSwitchTransmittedPacketDropEvent |
LogicalSwitch |
1.0 |
vRNI-Majority of NSX Edges in the ECMP Cluster are currently down, which has significantly degraded the capacity of the cluster |
Verify that the VM for each NSX Edge is running.Verify that the VM for each NSX Edge is connected to the network. |
NSXMajorityEcmpEdgesDownEvent |
EdgeServicesGateway |
1.0 |
vRNI-Data Source Not Running |
DATA_PROVIDER_NOT_RUNNING_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Firewall configuration update to an NSX host has timed out. The host is not synced with the latest firewall configuration version. |
|
ConfigUpdateOnHostFailedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Switch Port is operationally down. |
Check the operational status of the specified switch port. |
SwitchPortOperationalDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when the number of Hosts in a VMC SDDC exceeds limits. |
Deploy a new VMC SDDC. |
VMCHostLimitExceededEvent |
VMwareAdapter |
1.0 |
vRNI-VDR port is not found on the Host for the specified VXLAN, which might create routing issue. |
VirtualDistributedRoutingEvent |
HostSystem |
1.0 |
|
vRNI-High Disk Utilization |
HIGH_DISK_UTILIZATION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-BFD profile was deleted on NSX-T Manager after "Enable Virtual Infrastructure metric collection" was enabled at Network Insight |
NSXT_LATENCY_NO_BFD_PROFILE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Manager Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceManagerStatusEvent.recommendation-0. |
NSXTMPNodeServiceManagerStatusEvent |
ManagementNode |
1.0 |
vRNI-The connection between the control plane agent on an NSX host and its primary NSX Controller for one or more logical switches is not established. This condition can result in stale information on the host and NSX Controllers. |
|
HostNetworkControlPlaneConnectionFailureEvent |
HostSystem |
1.0 |
vRNI-Devices with Port-channel Member interfaces connecting to Non-port-channel Members |
Ensure that the peer port of a port channel is a port channel as well. |
UnderlayPortChannelMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Some of the NSX Controllers in the cluster are not communicating with the NSX Manager, which is preventing the cluster from establishing a majority |
|
NSXControllerClusterMajorityEvent |
ControllerCluster |
1.0 |
vRNI-NSX-T Compute Manager Connection status is not up. |
Please check connectivity between NSX-T Compute Manager and NSX-T. |
NSXTComputeManagerConnectionStatusNotUpEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The logical switching and routing information on a host is not in sync with the NSX Controller information |
|
HostNetworkControlPlaneNotSyncedEvent |
HostSystem |
1.0 |
vRNI-IPFIX cannot be enabled since no DVS found |
NO_DVS_AVAILABLE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A threshold-crossing amount of packet drops have been detected on the vnic interface of an NSX Edge Gateway. |
Check the state and MTU of specified interface. |
RouterInterfacePacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX Manager attempted to re-establish the message bus channel when the prepared host connected back to vCenter Server. This connection again failed, and dependent NSX services were not notified. |
|
HostMessagingConfigurationFailedEvent |
HostSystem |
1.0 |
vRNI-One or more Kubernetes Cluster's Kube Config file in PKS is not valid. |
PKS_KUBERNETES_UNKNOWN_HOST_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A backup of the environment has not been performed. Proper backup of all NSX components is crucial to restore the system to its working state in the event of a failure |
Configure scheduled backups for NSX Manager or take an immediate manual backup. See also 'NSX Backup and Restore' in the NSX Administration Guide. |
NSXBackupNotRecordedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Password Authentication Mode Disabled |
PWD_AUTH_MODE_DISABLED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Host Node Pnic Status is 'Unknown'. |
Please check if pNIC is properly connected. |
NSXTHostNodePnicStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-BGP Neighbor is not in established state. |
NSXTBGPNeighbourStateEvent |
TransportNode |
1.0 |
|
vRNI-Port Mode setting (access/trunk) of underlay switch ports do not match |
Ensure that the port mode of both the ports match. |
UnderlayPortModeMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A service VM or device for Palo Alto Networks is in a not connected state with Panorama |
Check network connectivity between Panorama and the specified Palo Alto service VM. |
PanDeviceInDisconnectedStateEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Received packets are getting dropped on the NSX-T Logical Port and associated entities might get affected. |
Check if there is MTU mismatch on the port or any firewall rule is responsible for dropping of received packets. |
NSXTLogicalPortReceivedPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Edge Node Roll-up Status is 'Down'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTEdgeNodeStatusDownEvent |
TransportNode |
1.0 |
vRNI-One or more NSX Edge interfaces are down. |
Check the admin status of the interfaces on the NSX Logical Router. |
EdgeInterfacesDownEvent |
LogicalRouter |
1.0 |
vRNI-One or more Fabric Nodes are added as standalone hosts in NSX-T. Virtual Machines on those hosts will not be visible in vRNI. |
Add the vCenter server managing the standalone hosts as a Compute Manager on NSX-T Manager. |
NSXTStandaloneHostsEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Number of members in application exceeds supported limit |
Reduce number of members in the application. |
ArkinApplicationMemberLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Nodes Version Mismatch detected |
NODES_VERSION_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Node Statistics Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNodeStatsStatusEvent.recommendation-0. |
NSXTMPNodeServiceNodeStatsStatusEvent |
ManagementNode |
1.0 |
vRNI-All NSX Edges in the ECMP Cluster are currently down, which is preventing upstream communication |
|
NSXAllEcmpEdgesDownEvent |
EdgeServicesGateway |
1.0 |
vRNI-NSX-T Edge Node Tunnel Status is 'Down'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTEdgeNodeTunnelStatusDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when BGP status is Down. |
HybridConnectBgpStatusDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-One or more essential services are not healthy. |
NOT_ALL_SERVICES_HEALTHY_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Memory usage of analytics process has exceeded maximum allocated limit. Please follow resolution steps to re-enable processing |
ANALYTICS_MEMORY_LIMITS_EXCEEDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Webhook is not running on the Collector(Proxy) VM |
WEBHOOK_NOT_RUNNING_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-AWS Security Groups available with AWS Region. |
AWSRegionSGLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSXT IPFIX No Ipfix Profile |
NSXT_IPFIX_NO_IPFIX_PROFILE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-More than 90% of VXLAN segment IDs have been used |
Add additional logical segment IDs to the NSX transport zone. |
VxLanRangeExhaustEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more OSPF areas on the NSX Edge Services Gateway or DLR are not configured to use MD5 authentication, which could compromise information about the network |
Configure the NSX logical router to use MD5 authentication for all OSPF areas. |
OspfInsecureAuthRouterEvent |
LogicalRouter |
1.0 |
vRNI-Unknown Host |
UNKNOWN_HOST_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Number of applications in ServiceNow exceeds NI system limit. |
SERVICE_NOW_APP_LIMIT_EXCEEDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The SpoofGuard configuration was not applied to the specified vNIC on the host. |
|
SpoofguardApplyToVnicFailedEvent |
VirtualMachine |
1.0 |
vRNI-Underlay device temperature threshold exceeded event. |
Check the specific sensor on underlay device. |
UnderlayDeviceTemperatureThresholdExceededEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Both VMs of Edge HA are in active state. The most common issue is split-brain, caused by underlying network connectivity loss. |
|
NSXEdgeSplitBrainEvent |
EdgeServicesGateway |
1.0 |
vRNI-Appliance certificate expired. |
REG_CERT_EXPIRED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-No syslog server is configured for the NSX Controller. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration |
Configure syslog server for NSX Controller. |
ControllerSysLogServerEvent |
Controller |
1.0 |
vRNI-NSX-T Host Node has lost manager connectivity. |
NSXTHostNodeMgmtConnectivityStatusDownEvent |
TransportNode |
1.0 |
|
vRNI-Policy Service status has turned to stopped. |
EventInfo.NSXTMPNodeServicePolicyStatusEvent.recommendation-0. |
NSXTMPNodeServicePolicyStatusEvent |
ManagementNode |
1.0 |
vRNI-NSXT IPFIX no new Collector Profile can be added |
NSXT_IPFIX_NO_NEW_COLLECTOR_PROFILE_CAN_BE_ADDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A distributed firewall rule was not applied to a host's vNIC. |
|
ApplyRuleToVnicFailedEvent |
VirtualMachine |
1.0 |
vRNI-Transmitted packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. |
Check the state and MTU of specified interface. |
NSXTTxPacketDropOnMPNicEvent |
ManagementNode |
1.0 |
vRNI-One or more NSX Edges in the ECMP Cluster are currently down, which has degraded the capacity of the cluster |
|
NSXEcmpEdgeDownEvent |
EdgeServicesGateway |
1.0 |
vRNI-VeloCloud Edge Degraded Voice QOE Event. |
Verify that the Edge is in healthy state. |
VeloCloudEdgeDegradedVoiceQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-An update to the SpoofGuard configuration failed for the host. |
|
SpoofguardConfigUpdateOnHostFailedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The Latency Node Group configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. |
NSXT_LATENCY_NODE_GROUP_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Host Node Tunnel Status is 'Down'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTHostNodeTunnelStatusDownEvent |
TransportNode |
1.0 |
vRNI-This event is raised when the number of VMs in a VMC SDDC exceeds limits. |
|
VMCVMLimitExceededEvent |
VMwareAdapter |
1.0 |
vRNI-Transmitted packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. |
Check the state and MTU of specified interface. |
NSXTTxPacketDropOnHostTnNicEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more DLR networks cannot be reached from the uplink interface on the NSX Edge router. This condition suggests either an OSPF configuration error on the Edge-router/DLR or route not configured on uplink router. |
|
DLRNetworksNotReachableEvent |
LogicalRouter |
1.0 |
vRNI-AWS Flow Log Access Denied Exception. This event is raised when user does not have necessary permissions required to collect flow logs. |
AWS_FLOW_LOG_ACCESS_DENIED_EXCEPTION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Permitted VLANs in underlay trunk switch ports do not match |
Ensure that the allowed VLANs in both the trunk ports match. |
UnderlayPortTrunkMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Edge Node Tunnel Status is 'Unknown'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTEdgeNodeTunnelStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-NSX-T management node has lost management cluster connectivity. |
Check if the node has proper network connectivity with management cluster. |
NSXTMPNodeToMgmtClusterConnectivityEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The version of NIOS is not supported. |
UNSUPPORTED_INFOBLOX_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Error connecting to data source |
CONNECTION_ERROR_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Invalid Data Source Config |
WARN_CONFIG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A configuration update pushed to hosts over the NSX messaging channel did not complete. |
|
HostMessagingConfigurationFailedEvent |
HostSystem |
1.0 |
vRNI-An NSX Edge has failed to deploy. This condition may indicate that an NSX Edge has been configured without actually being deployed. |
|
EdgeNotDeployedEvent |
EdgeServicesGateway |
1.0 |
vRNI-The distributed firewall rule table differs between the host and NSX Manager. |
|
HostWithStaleFirewallRulesEvent |
HostSystem |
1.0 |
vRNI-There is no syslog server configured on the NSX Manager. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration |
Configure Syslog Server for NSX Manager. |
NSXSysLogServerEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NTP Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNTPStatusEvent.recommendation-0. |
NSXTMPNodeServiceNTPStatusEvent |
ManagementNode |
1.0 |
vRNI-An NSX management appliance service is down |
|
NSXComponentEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Invalid SNMP Connection |
SNMP_CONNECTION_INVALID_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-High Availability is not enabled on the NSX Edge, which may impact network availability. |
|
EdgeHANotConfiguredEvent |
EdgeServicesGateway |
1.0 |
vRNI-Upgrade Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNSXUpgradeAgentStatusEvent.recommendation-0. |
NSXTMPNodeServiceNSXUpgradeAgentStatusEvent |
ManagementNode |
1.0 |
vRNI-Event reported by kubernetes cluster |
KubernetesBaseEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T controller node has lost control cluster connectivity. |
Check if the node has proper network connectivity with control cluster. |
NSXTControllerNodeToControlClusterConnectivityEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Disk Cleanup service is unhealthy. |
DISK_CLEANUP_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-vRealize Network Insight Content Pack not found in Log Insight |
vRNI_CONTENT_PACK_NOT_INSTALLED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-This event is raised when pool member of load balancer is down. To know the pool members which are down, search 'Pool Member where state |
|
LBPoolMemberDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Connection Refused |
CONNECTION_REFUSED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Network and security container information used with the NSX distributed firewall or with Service Composer failed to be updated on an NSX host. |
|
ContainerConfigUpdateOnVnicFailedEvent |
VirtualMachine |
1.0 |
vRNI-NSX-T Host Node Tunnel Status is 'Degraded'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTHostNodeTunnelStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-Communication will be disrupted because Vlan on uplink port of Tier 0 router is different than Vlan on the external gateway. |
Vlan is misconfigured on the tier-0 router. Make sure Vlan matches with the Vlan on the external gateway. |
NSXTDoubleVlanTaggingEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Flow Collection Error |
FLOW_COLLECTION_ERROR_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The distributed firewall is configured to allow all traffic by default, which increases the potential attack surface of the network |
Configure the default firewall rule to block all traffic. |
NSXFirewallDefaultAllowAllRulesEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Data Retention (Config Store Maintenance) service is unhealthy. |
CONFIG_STORE_CLEANUP_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-There are fewer than three active controllers, which may cause provisioning operations to fail |
|
NSXControllerNotActiveCountEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Audit logs are currently excluded from backup, which could cause loss of security-related events |
Enable backups of NSX Manager audit logs from the NSX Manager UI by going to Manage > Backup and Restore. |
NSXBackupAuditLogExcludedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Underlay device event. |
Check the underlay device. |
UnderlayDeviceGenericEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when no NIC associated with IP of service node of load balancer is found |
Ensure that VM which has IP of service node exist. |
LBServiceNodeIPNotFoundEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when the number of Hosts per Cluster in a VMC SDDC exceeds limit. |
Deploy a new Cluster in VMC SDDC. |
VMCHostPerClusterLimitExceededEvent |
ClusterComputeResource |
1.0 |
vRNI-Password Authentication Mode Disabled for Arista |
PWD_AUTH_MODE_DISABLED_ARISTA_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Host Node Pnic Status is 'Down'. |
Please check if pNIC is properly connected. |
NSXTHostNodePnicStatusDownEvent |
TransportNode |
1.0 |
vRNI-A threshold-crossing temperature detected on host FRUs. |
ThresholdExceededEventDataSourceTemperature-0. |
ThresholdExceededEventDataSourceTemperature |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Logical switch information between the primary NSX controller and all hosts where the logical switch is used does not match. This event may indicate an error condition is occurring after a sharding change. |
|
HostNetworkControlPlaneMismatchEvent |
HostSystem |
1.0 |
vRNI-Mismatch in service appliance information between NSX Manager and Check Point. |
|
CheckpointNsxServiceApplianceViewMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Unsupported NSXT Version |
UNSUPPORTED_NSXT_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-AWS Security Groups available with AWS Interface. |
AWSInterfaceSGLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-This event is raised when virtual server of load balancer is disabled |
To enable virtual server, open load balancer GUI and check virtual server state. |
LBVirtualServerDisableEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The NSX feature version of the prepared cluster doesn't match with that of NSX Manager. |
Execute 'Sync Logical Services' from the Installation screen. |
ClusterFeatureVersionMismatchEvent |
ClusterComputeResource |
1.0 |
vRNI-CM Inventory Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceCmInventoryStatusEvent.recommendation-0. |
NSXTMPNodeServiceCmInventoryStatusEvent |
ManagementNode |
1.0 |
vRNI-Collector VM configuration incomplete. |
APPLIANCE_NOT_CONFIGURED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Appliance Disk not configured according to Disk Guidance. |
DISK_ALLOCATION_INSUFFICIENT_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX Controller Not Found |
NSX_CONTROLLER_NOT_FOUND_EVENT |
VirtualMachine |
1.0 |
|
vRNI-The MTU configured on one or more interfaces on the Edges in the same Layer 2 network does not match, which may impact network performance |
Configure the same MTU on all Edge Interfaces which are in same Layer 2 network. |
NSXEdgeMtuMismatchEvent |
EdgeServicesGateway |
1.0 |
vRNI-Panorama dynamic membership definition update from NSX Manager is delayed. This condition may indicate a network connectivity issue or an issue with NSX Manager's NetX service. |
|
PanNsxDynamicUpdateDelayedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The Latency Service Config configured on NSX-T is different from this Network Insight deployment. As a result, Network Insight is not receiving Latency information from NSX-T. |
NSXT_LATENCY_SERVICE_CONFIG_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Host Node Roll-up Status is 'Unknown'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTHostNodeStatusUnknownEvent |
TransportNode |
1.0 |
vRNI-Router interafce is operationally down. |
Check the operational status of the specified router interface. |
RouterInterfaceOperationalDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A distributed firewall configuration update failed to be applied to a vNIC on an NSX prepared host. |
|
FilterConfigApplyOnHostFailedEvent |
HostSystem |
1.0 |
vRNI-NSX-T Edge Node is not able to to communicate with one or more controllers. |
NSXTControllerConnectivityDegradedEvent |
TransportNode |
1.0 |
|
vRNI-The number of records from Infoblox exceeds current limit |
INFOBLOX_RECORD_LIMIT_EXCEEDED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-One or more Kubernetes Cluster Service Accounts do not have sufficient privileges. |
KUBERNETES_INSUFFICIENT_PRIVILEGES_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Migration Co-ordinator Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceMigrationCoordinatorStatusEvent.recommendation-0. |
NSXTMPNodeServiceMigrationCoordinatorStatusEvent |
ManagementNode |
1.0 |
vRNI-The message bus and/or control plane agent daemon on this Host is experiencing connection failures with NSX Controller or NSX Manager |
|
ModuleNetworkConnectionFailureEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when multiple NICs associated with IP of service node of load balancer are found |
Check if there are more than one VMs/VNICs with the IP address used in this service node. |
LBServiceNodeMultipleNicFoundEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-SSH Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceSSHStatusEvent.recommendation-0. |
NSXTMPNodeServiceSSHStatusEvent |
ManagementNode |
1.0 |
vRNI-Azure flow collection permissions or Azure flows not available |
AZURE_FLOW_COLLECTION_ERROR_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Large SDMS Dropped, some information is not processed |
LARGE_SDMS_DROPPED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The NSX distributed logical router control VM is deployed to the same host as one or more NSX Edges that are configured for ECMP. |
Move the DLR control VM to a different host. |
LogicalRouterDeployedOnEcmpEdgeHostEvent |
LogicalRouter |
1.0 |
vRNI-Invalid Response From Data Source |
INVALID_RESPONSE_FROM_DATASOURCE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-This event is raised when the number of Clusters in a VMC SDDC exceeds limits. |
Deploy a new VMC SDDC. |
VMCClusterLimitExceededEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Recent data is still being indexed. Search results may be inaccurate. |
INDEXER_LAG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-No access to shell for F5 Load Balancer. Network Insight will not be able to fetch any information required for visibility. |
BIGIP_INSUFFICIENT_SHELL_ACCESS_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Unexpected Datasource Type or Version |
UNEXPECTED_DS_TYPE_OR_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Updated information on the host messaging channel failed to be sent to the NSX host. |
|
HostMessagingConnectionReconfigurationFailedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A distributed firewall rule is masked by one or more preceding rules. This condition may indicate a configuration error, such as a redundant rule. |
Validate the modification was expected. If not planned or expected, configure the required firewall rule(s). |
FirewallRuleMaskEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-DataStore Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceDataStoreStatusEvent.recommendation-0. |
NSXTMPNodeServiceDataStoreStatusEvent |
ManagementNode |
1.0 |
vRNI-VeloCloud Link Degraded Video QOE Event. |
Verify that the Link is in healthy state. |
VeloCloudLinkDegradedVideoQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-The version of NIOS cannot be determined. |
UNKNOWN_INFOBLOX_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-SMTP Not Configured |
SMTP_NOT_CONFIGURED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Management Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceMgmtPlaneBusStatusEvent.recommendation-0. |
NSXTMPNodeServiceMgmtPlaneBusStatusEvent |
ManagementNode |
1.0 |
vRNI-Transmitted packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. |
Check the state and MTU of specified interface. |
NSXTTxPacketDropOnEdgeTnNicEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-VeloCloud Link Degraded Transactional QOE Event. |
Verify that the Link is in healthy state. |
VeloCloudLinkDegradedTransQoeEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Host Node Roll-up Status is 'Down'. |
Please check the status of the pNICs, management & control connections, tunnels and agents for this NSX-T Transport Node. |
NSXTHostNodeStatusDownEvent |
TransportNode |
1.0 |
vRNI-An infrastructure VM is experiencing a high memory condition. This condition may lead to an NSX service disruption. |
Check the memory resource allocated to the specified VM. Allocate more memory if required. |
ServiceVMHighMemoryUsageEvent |
VirtualMachine |
1.0 |
vRNI-An NSX infrastructure VM is experiencing high CPU. This condition may lead to a service disruption. |
Check the underlying Host for resource usage. Migrate some of the VMs to other Hosts. |
ServiceVMHighCPUUsageEvent |
VirtualMachine |
1.0 |
vRNI-Underlay device LLDP neighbour removed event. |
Check the LLDP neighbour details on underlay device. |
UnderlayDeviceLldpNeighbourRemovedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-User defined Problem when search result changes |
SearchStreamMembershipProblemEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Compute Managers Not Found |
COMPUTE_MANAGERS_NOT_FOUND_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Indexing Aborted |
INDEXING_ABORTED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-MTU setting of underlay switch ports do not match |
Ensure that the MTU setting on both the ports match. |
UnderlayMtuMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Last data collection on data source was more than 30 minutes ago |
COLLECTION_LAG_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Communication failure detected between NSX Manager and Edge VM. |
|
EdgeVMCommunicationFailureEvent |
LogicalRouter |
1.0 |
vRNI-Unsupported NSX Version |
UNSUPPORTED_NSX_VERSION_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX IPFIX Status Mismatch |
NSX_IPFIX_STATUS_MISMATCH_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Logical Port Operational Status is 'Down'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. |
NSXTLogicalPortOperationalStatusDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Duplicate IP Address found on multiple ports |
Ensure that the ports have unique IP addresses. |
UnderlayDuplicateIPAddressEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-This event is raised when VM associated with pool member of load balancer is down |
Check if VM associated with pool member is powered on and running. |
LBPoolMemberVMDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-DFW IPFIX Profile is not found on NSX Policy Manager |
POLICY_MANAGER_NO_DFW_IPFIX_PROFILE |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A threshold-crossing amount of buffer usage have been detected on a router interface. |
Check the traffic on specified router interface. |
RouterInterfaceBufferThresholdExceededEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Loop detected in forwarding path |
Update device configuration to eliminate loop. |
LoopDetectionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more essential services are not running. |
NOT_ALL_SERVICES_RUNNING_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-The MTU configured on interface(s) of Tier-0 logical router do not match with the interface(s) of uplink switch/router from same L2 network. This may impact network performance. |
Configure same MTU on interfaces between Tier-0 logical router and uplink routers. |
NSXTMtuMismatchEvent |
EdgeServicesGateway |
1.0 |
vRNI-VeloCloud Link Packet Loss Event Tx. |
Verify that the Link is in healthy state. |
VeloCloudLinkLostPacketEventTx |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Edge State of VeloCloud Edge is not connected. |
Verify that the VeloCloud Edge is UP. |
VeloCloudEdgeDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-AWS Security Groups available with AWS VPC. |
AWSVPCSGLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Network Insight IPFIX Collector IP and port are not present in DFW IPFIX Collector Profile on NSX Policy Manager. |
POLICY_MANAGER_VRNI_DFW_IPFIX_COLLECTOR_ABSENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Search Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceSearchStatusEvent.recommendation-0. |
NSXTMPNodeServiceSearchStatusEvent |
ManagementNode |
1.0 |
vRNI-A threshold-crossing amount of packet drops have been detected on the specified device. |
Check the state and MTU of specified interface |
DevicePacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A threshold-crossing amount of packet drops have been detected on the switch port associated with the specified physical NIC. |
Check the state and MTU of the specified switch port. |
PnicUnderlyingSwitchPortPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-An NSX Edge VM is not responding to health check by NSX Manager |
|
EdgeVMNotRespondingEvent |
LogicalRouter |
1.0 |
vRNI-NSXT IPFIX No Collector Profile |
NSXT_IPFIX_NO_COLLECTOR_PROFILE_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T Edge Node Tunnel Status is 'Degraded'. |
Please check the status of the tunnel interfaces for this NSX-T Transport Node. |
NSXTEdgeNodeTunnelStatusDegradedEvent |
TransportNode |
1.0 |
vRNI-Message Bus Client Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceNSXMessageBusStatusEvent.recommendation-0. |
NSXTMPNodeServiceNSXMessageBusStatusEvent |
ManagementNode |
1.0 |
vRNI-Failed to expand disk partition. |
EXPAND_PARTITION_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-Received packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. |
Check the state and MTU of specified interface. |
NSXTRxPacketDropOnHostTnNicEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-One or more BGP neighbours are not in established state. |
NSXEdgeBGPNeighbourDownEvent |
EdgeServicesGateway |
1.0 |
|
vRNI-Hardware Gateway Binding Switch Port is down |
EventInfo.HardwareVTEPPortDownEvent.recommendation-0. |
HardwareVTEPPortDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-A threshold-crossing amount of packet drops have been detected on a VM interface. |
Check the state and MTU of the specified Virtual Machine interface. |
VnicPacketDropEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-An MTU mismatch was found in the path between a VTEP and its physical switch port |
|
MTUMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-CM Inventory Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceClusterManagerStatusEvent.recommendation-0. |
NSXTMPNodeServiceClusterManagerStatusEvent |
ManagementNode |
1.0 |
vRNI-Port duplex setting of underlay switch ports do not match |
Ensure that the duplex setting of both the ports match. |
UnderlayDuplexMismatchEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Two or more messaging-channel heartbeat messages between NSX Manager and an NSX host were missed. |
|
HostMessagingInfrastructureDownEvent |
HostSystem |
1.0 |
vRNI-NSX Manager backups are not configured. Proper backup of all NSX components is crucial to restore the system to its working state in the event of a failure |
|
NSXBackupEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-VXLAN does not have an uplink on specified Host |
Assign proper uplink for specified layer2 network. |
L2NetworkUplinkMissingEvent |
TransportNode |
1.0 |
vRNI-Inbound Rules available with AWS Security Group. |
AWSSGInboundRuleLimitEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-A threshold-crossing CPU usage detected on host FRUs. |
ThresholdExceededEventDataSourceCpuUsage-0. |
ThresholdExceededEventDataSourceCpuUsage |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Credential Encryption Failed |
FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-This event is raised when pool of load balancer is down |
Ensure that pool has at least one functional pool member. |
LBPoolDownEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Most of the allocated disk space for an infrastructure VM has been consumed. The infrastructure VM may become inaccessible or lead to a service disruption. |
|
ServiceVMHighDiskUsageEvent |
VirtualMachine |
1.0 |
vRNI-Install Upgrade Service status has turned to stopped. |
EventInfo.NSXTMPNodeServiceInstallUpgradeEvent.recommendation-0. |
NSXTMPNodeServiceInstallUpgradeEvent |
ManagementNode |
1.0 |
vRNI-A Check Point' security appliance VM was not found on a host in an NSX prepared cluster. |
Check the state of the Check Point Service VM on the specified host. Ensure that it is booted properly. |
CheckpointNsxServiceVMNotFoundOnHostEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Data Retention (Metric Store Maintenance) service is unhealthy. |
METRIC_STORE_UPDATER_FAILED_EVENT |
NETWORK_INSIGHT_OTHERS |
1.0 |
|
vRNI-NSX-T has a Compute Manager which is not added as a data source in vRNI. |
Check if the Compute Manager registered in NSX-T Manager is also added as a data source in vRNI. |
NSXTVcNotAddedEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-NSX-T Edge Node is not able to communicate with any of the controllers. |
NSXTControllerConnectivityDownEvent |
TransportNode |
1.0 |
|
vRNI-Underlay device fan removed or not working event. |
Check the specific fan on underlay device. |
UnderlayDeviceFanMalFunctionEvent |
NETWORK_INSIGHT_OTHERS |
1.0 |
vRNI-Outlier violation event. | Event generated as a result of the anomalous entity. | AnalyticsOutlierEvent | NETWORK_INSIGHT_TIER | 1.1 |