Redundant sessions are connected to multiple UAG objects.
Problem
Connection of redundant sessions to multiple UAG objects takes place.
Cause
The UAG is incorrectly registered with more than one Connection Server.
Solution
- ♦ If you want to register the same UAG (UAG1) with a different CS (CS2), then unregister it in another CS (CS1).