You can adjust the settings of your storage array, to modify how Site Recovery Manager and vCenter Server communicate with the storage replication adapter (SRA).

Procedure

  1. Click Sites in the Site Recovery Manager interface, right-click the site on which to change settings, and select Advanced Settings.
  2. Click storage.
  3. Modify the storage settings.

    Option

    Action

    Change SRA update timeout

    Type a new value in the storage.commandTimeout text box.

    Change the maximum number of concurrent SRA operations

    Type a new value in the storage.maxConcurrentCommandCnt text box.

    Change the minimum amount of time in seconds between datastore group computations

    Type a new value in the storage.minDsGroupComputationInterval text box.

    Change the interval between status updates for ongoing data synchronization operations

    Type a new value in the storage.querySyncStatusPollingInterval text box.

    Change the interval between storage array discovery checks

    Type a new value in the storage.storagePingInterval text box.

    Change the maximum amount of time permitted for data synchronization operations to complete

    Type a new value in the storage.syncTimeout text box.

  4. Click OK to save your changes.