You can adjust the storage settings to modify how Site Recovery Manager and vCenter Server communicate with the storage replication adapter (SRA).

Procedure

  1. In the vSphere Web Client, click Site Recovery > Sites, and select a site.
  2. On the Manage tab, click Advanced Settings.
  3. Click Storage.
  4. Click Edit to modify the storage settings.

    Option

    Action

    Change timeout in seconds for executing an SRA command. The default value is 300 seconds.

    Enter a new value in the storage.commandTimeout text box.

    Change the maximum number of concurrent SRA operations. The default value is 5.

    Enter a new value in the storage.maxConcurrentCommandCnt text box.

    Change the minimum amount of time in seconds between datastore group computations. The default value is 0.

    Enter a new value in the storage.minDsGroupComputationInterval text box.

    Change the interval between status updates for ongoing data synchronization operations. The default value is 30 seconds.

    Enter a new value in the storage.querySyncStatusPollingInterval text box.

    Change the interval between storage array discovery checks. The default value is 86400 seconds (24 hours).

    Enter a new value in the storage.storagePingInterval text box.

    Change the maximum amount of time permitted for data synchronization operations to complete. The default value is 86400 seconds (24 hours).

    Enter a new value in the storage.syncTimeout text box.