Recovery plan execution might fail to power on a VM.
Problem
When you run a recovery plan,
Site Recovery Manager might fail to power on a VM with
(vmodl.fault.InvalidArgument:path) error. The following error message appears in the
Site Recovery Manager recovery site server logs:
YYYY-MM-DDT20:24:35.996-08:00 error vmware-dr[02448] [SRM@6876 sub=Recovery ...] Plan execution (test workflow) failed;
plan id: 34f86036-3bc7-4c2d-a841-e15c5d781532, plan name: HBRRP_LIMITS, error: (vmodl.fault.InvalidArgument) {
--> faultCause = (vmodl.MethodFault) null,
--> faultMessage = <unset>,
--> invalidProperty = "path"
--> msg = "A specified parameter was not correct: path"
--> }
-->
Cause
This error is a result of a failing 'Relocating VM before powered on' operation on the target destination
ESXi host. The related error message in the
ESXi vpxa service logs is:
YYYY-MM-DDT03:56:48.255Z error vpxa[2099931] [Originator@6876 sub=vpxaVmprov opID=failedOpId]
Failed to canonicalize vm register path;
/vmfs/volumes/.../recoveredVm.vmx, err: 16(Device or resource busy)
...
YYYY-MM-DDT03:56:48.256Z info vpxa[2099931] [Originator@6876 sub=Default opID=failedOpId]
[VpxLRO] -- ERROR task-1824 -- vpxa -- vpxapi.VpxaService.registerVm: vmodl.fault.InvalidArgument:
--> Result:
--> (vmodl.fault.InvalidArgument) {
--> faultCause = (vmodl.MethodFault) null,
--> faultMessage = <unset>,
--> invalidProperty = "path"
Solution
Re-run the failed recovery plan.