Provides the server's uplink PDU information so that IT administrator can better understand their servers power supply status. The follow metrics and properties are available for each PDU instance in the Aria Operations Manager environment.
Metric Key |
Type |
Unit |
Description |
---|---|---|---|
Current Load |
Double |
% |
The current load of the PDU. |
Power Load |
Double |
% |
The power load of the PDU. |
Total Current |
Double |
A |
The total current of the PDU. |
Total Power |
Double |
KW |
The total power usage of the PDU. |
Humidity |
Double |
% |
The humidity of the PDU. |
Temperature |
Double |
°C |
The temperature the PDU. |
Inlets: index|Active Power |
Double |
W |
The active power of the inlet identified by the index. |
Inlets: index|Apparent Power |
Double |
W |
The apparent power of the inlet identified by the index. |
Inlets: index|Current AMPS |
Double |
A |
The current of the inlet identified by the index. |
Inlets: index|Free Capacity |
Double |
A |
The free capacity of the inlet. |
Inlets: index|Voltage |
Double |
V |
The voltage of the inlet. |
Inlets: index|L1|Current |
Double |
A |
The L1 current for the inlet. |
Inlets: index|L2|Current |
Double |
A |
The L2 current for the inlet (only valid for the three-phase case). |
Inlets: index|L3|Current |
Double |
A |
The L3 current for the inlet (only valid for the three-phase case). |
Outlets: index|Active Power |
Double |
W |
The active power of the outlet identified by index. |
Outlets: index|Apparent Power |
Double |
W |
The apparent power of the outlet identified by the index. |
Outlets: index|Current AMPS |
Double |
A |
The current of the outlet. |
Outlets: index|Free Capacity |
Double |
A |
The free current capacity. |
Outlets: index|Voltage |
Double |
V |
The voltage of the outlet. |
Properties Key |
Type |
Unit |
Description |
---|---|---|---|
AssetNumber |
Integer |
The assetNumber of the PDU. |
|
Cabinet |
String |
The cabinet name where the PDU is located. |
|
Manufacturer |
String |
The manufacturer of the PDU. |
|
Model |
String |
The model of the PDU. |
|
Name |
String |
The name of the PDU. |
|
Rated Current |
Double |
A |
The rated current of the PDU. |
Rated VA High |
Double |
VA |
The high value of the rated VA of the PDU |
Rated VA Low |
Double |
VA |
The low value of the rated VA of the PDU. |
Rated Voltage High |
Double |
V |
The high rated voltage of the PDU. |
Rated Voltage Low |
Double |
V |
The low rated voltage of the PDU. |
Serial Number |
String |
The serial number of the PDU. |
|
Tag |
String |
The tag of the PDU. |
|
Location|Region |
String |
The region name. |
|
Location|Country |
String |
The country name. |
|
Location|City |
String |
The city name. |
|
Location|Building |
String |
The building name. |
|
Location|Floor |
String |
The floor name. |
|
Location|Room |
String |
The room name. |
|
Location|Row |
String |
The row name. |
|
Inlet Phase |
String |
The phase type of the inlet. |