The Management Pack for HPE ProLiant collects the metrics listed in the following table, according to HPE ProLiant resource kind.

Resource Kind

Resource Group

Resource Attribute

Attribute Type

Attribute Source

Attribute Description

HPE Servers Adapter Instance

License

Blades and Racks

double

iLO, Onboard Administrator

Number of blade and rack licenses required for this adapter instance.

HPE Servers Container

Relationships

Enclosure Children

string

iLO

All HPE enclosures.

HPE Servers Container

Relationships

Rack Children

string

iLO

All HPE racks.

VMware VMs on HPE Container

Relationships

Virtual Machine Children

string

iLO

The virtual machines running on HPE servers.

VMware Hosts on HPE Container

Relationships

Host System Children

string

iLO

The host systems running on HPE servers.

HPE Enclosure

Relationships

Servers Parent

string

iLO,OA

Servers container.

HPE Enclosure

Relationships

Chassis Children

string

iLO

All the chassis in this enclosure.

HPE Enclosure

Relationships

Blade Children

string

OA

All the blades in this enclosure.

HPE Enclosure

Relationships

Fan Children

string

OA

All the fans on this enclosure.

HPE Enclosure

Relationships

Power Supply Children

string

OA

All the power supplies on this enclosure.

HPE Enclosure

Relationships

Interconnect Children

string

OA

All the interconnects on this enclosure.

HPE Enclosure

Details

Asset Tag

string

VCM

Asset Tag of the Enclosure for identification

HPE Enclosure

Details

Description

string

VCM

Description of the Enclosure provided by HPE

HPE Enclosure

Details

Number of Device Bays

integer

VCM

Number of Device Bays

HPE Enclosure

Details

ID

string

VCM

The ID of the Enclosure.

HPE Enclosure

Details

Number of I/O Bays

integer

VCM

Number of I/O Bays

HPE Enclosure

Details

Manufacturer

string

VCM

Manufacturer of the Enclosure

HPE Enclosure

Details

OA1 IP Address

string

VCM

IP Address of Onboard Administrator 1

HPE Enclosure

Details

OA1 IPv6 Address

string

VCM

IPv6 Address of Onboard Administrator 1

HPE Enclosure

Details

OA2 IP Address

string

VCM

IP Address of Onboard Administrator 2

HPE Enclosure

Details

OA2 IPv6 Address

string

VCM

IPv6 Address of Onboard Administrator 2

HPE Enclosure

Details

Onboard Administrator Firmware Version

string

OA

Firmware Version of the Onboard Administrator

HPE Enclosure

Details

Part Number

string

OA

Part Number of the Enclosure

HPE Enclosure

Details

Primary

string

OA

Whether or not this is designated as the primary enclosure

HPE Enclosure

Details

Serial Number

string

OA

Serial Number of the Enclosure

HPE Enclosure

Details

Spare Part Number

string

VCM

Spare Part Number for the Enclosure

HPE Enclosure

Details

Spare Rack Name

string

VCM

Spare Rack Name for the enclosure

HPE Enclosure

Details

Name

string

OA,iLO

The name of the Enclosure.

HPE Enclosure

General (Deprecated)

Name (Deprecated)

string

iLO

The name of the enclosure.

HPE Enclosure

General (Deprecated)

UUID (Deprecated)

string

iLO

The universal unique identifier for this enclosure.

HPE Enclosure

Status

Communication Status

string

VCM

Communication Status of the Enclosure

HPE Enclosure

Status

Import Status

string

VCM

Import Status of the Enclosure

HPE Enclosure

Status

Onboard Administrator Status

string

VCM

Onboard Administrator Status

HPE Enclosure

Status

Operational Status

string

VCM

Operational Status of the Enclosure

HPE Enclosure

Status

Overall Status

string

VCM

Overall status of the Enclosure

HPE Enclosure

Status

Root Cause

string

VCM

Root Cause of the status

HPE Enclosure

Status

Status Cause

string

VCM

Cause of the status

HPE Blade

Relationships

Network Adapter Child

string

iLO

The network adapter on the blade.

HPE Blade

Relationships

Chassis Parent

string

iLO

The chassis this blade is in.

HPE Blade

Relationships

Enclosure Parent

string

OA

The enclosure this blade is in.

HPE Blade

Relationships

Port Child

string

OA

The ports on this blade.

HPE Blade

Relationships

Host System Parent

string

iLO

Host system parent.

HPE Blade

Details

Ambient Zone Temperature Sensors Above Caution

integer

OA

Number of Ambient Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

Ambient Zone Temperature Sensors Above Critical

integer

OA

Number of Ambient Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Average Ambient Zone Temperature

float

OA

Average Ambient Zone Temperature reported by the blade

HPE Blade

Details

Average CPU Zone Temperature

float

OA

Average CPU Zone Temperature reported by the blade

HPE Blade

Details

Average Chassis Zone Temperature

float

OA

Average Chassis Zone Temperature reported by the blade

HPE Blade

Details

Average Disk Zone Temperature

float

OA

Average Disk Zone Temperature reported by the blade

HPE Blade

Details

Average I/O Board Zone Temperature

float

OA

Average I/O Board Zone Temperature reported by the blade

HPE Blade

Details

Average Memory Zone Temperature

float

OA

Average Memory Zone Temperature reported by the blade

HPE Blade

Details

Average Power Supply Zone Temperature

float

OA

Average Power Supply Zone Temperature reported by the blade

HPE Blade

Details

Average System Zone Temperature

float

OA

Average System Zone Temperature reported by the blade

HPE Blade

Details

BIOS Version

string

OA,iLO

BIOS Version of the blade

HPE Blade

Details

Blade Number

string

OA

Slot number of the blade.

HPE Blade

Details

CPU Zone Temperature Sensors Above Caution

integer

OA

Number of CPU Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

CPU Zone Temperature Sensors Above Critical

integer

OA

Number of CPU Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Chassis Zone Temperature Sensors Above Caution

integer

OA

Number of Chassis Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

Chassis Zone Temperature Sensors Above Critical

integer

OA

Number of Chassis Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Current Power Consumption

integer

OA

The blade's current power consumption

HPE Blade

Details

Disk Zone Temperature Sensors Above Caution

integer

OA

Number of Disk Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

Disk Zone Temperature Sensors Above Critical

integer

OA

Number of Disk Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

I/O Board Zone Temperature Sensors Above Caution

integer

OA

Number of I/O Board Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

I/O Board Zone Temperature Sensors Above Critical

integer

OA

Number of I/O Board Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Management Processor Firmware Version

string

OA

The blade\'s management processor\'s firmware version

HPE Blade

Details

Management Processor IP Address

string

OA

The blade's management processor's IP Address

HPE Blade

Details

Management Processor MAC Address

string

OA

The blade's management processor's MAC Address

HPE Blade

Details

Management Processor Type

string

OA

The blade's management processor's type

HPE Blade

Details

Manufacturer

string

OA,iLO

Manufacturer of the blade

HPE Blade

Details

Maximum Ambient Zone Temperature

integer

OA

Maximum Ambient Zone Temperature reported by the blade

HPE Blade

Details

Maximum CPU Zone Temperature

integer

OA

Maximum CPU Zone Temperature reported by the blade

HPE Blade

Details

Maximum Chassis Zone Temperature

integer

OA

Maximum Chassis Zone Temperature reported by the blade

HPE Blade

Details

Maximum Disk Zone Temperature

integer

OA

Maximum Disk Zone Temperature reported by the blade

HPE Blade

Details

Maximum I/O Board Zone Temperature

integer

OA

Maximum I/O Board Zone Temperature reported by the blade

HPE Blade

Details

Maximum Memory Zone Temperature

integer

OA

Maximum Memory Zone Temperature reported by the blade

HPE Blade

Details

Maximum Power Supply Zone Temperature

integer

OA

Maximum Power Supply Zone Temperature reported by the blade

HPE Blade

Details

Maximum System Zone Temperature

integer

OA

Maximum System Zone Temperature reported by the blade

HPE Blade

Details

Memory Zone Temperature Sensors Above Caution

integer

OA

Number of Memory Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

Memory Zone Temperature Sensors Above Critical

integer

OA

Number of Memory Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Minimum Ambient Zone Temperature

integer

OA

Minimum Ambient Zone Temperature reported by the blade

HPE Blade

Details

Minimum CPU Zone Temperature

integer

OA

Minimum CPU Zone Temperature reported by the blade

HPE Blade

Details

Minimum Chassis Zone Temperature

integer

OA

Minimum Chassis Zone Temperature reported by the blade

HPE Blade

Details

Minimum Disk Zone Temperature

integer

OA

Minimum Disk Zone Temperature reported by the blade

HPE Blade

Details

Minimum I/O Board Zone Temperature

integer

OA

Minimum I/O Board Zone Temperature reported by the blade

HPE Blade

Details

Minimum Memory Zone Temperature

integer

OA

Minimum Memory Zone Temperature reported by the blade

HPE Blade

Details

Minimum Power Supply Zone Temperature

integer

OA

Minimum Power Supply Zone Temperature reported by the blade

HPE Blade

Details

Minimum System Zone Temperature

integer

OA

Minimum System Zone Temperature reported by the blade

HPE Blade

Details

Model

string

OA

The model of the blade.

HPE Blade

Details

Number of Ambient Zone Temperature Sensors

integer

OA

Number of Ambient Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of CPU Zone Temperature Sensors

integer

OA

Number of CPU Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of Chassis Zone Temperature Sensors

integer

OA

Number of Chassis Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of Disk Zone Temperature Sensors

integer

OA

Number of Disk Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of I/O Board Zone Temperature Sensors

integer

OA

Number of I/O Board Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of Memory Zone Temperature Sensors

integer

OA

Number of Memory Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of Power Supply Zone Temperature Sensors

integer

OA

Number of Power Supply Zone Temperature Sensors reported by the blade

HPE Blade

Details

Number of System Zone Temperature Sensors

integer

OA

Number of System Zone Temperature Sensors reported by the blade

HPE Blade

Details

Power Management Controller Version

string

OA,iLO

Power Management Controller Version of the blade's management processor

HPE Blade

Details

Power Supply Zone Temperature Sensors Above Caution

integer

OA

Number of Power Supply Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

Power Supply Zone Temperature Sensors Above Critical

integer

OA

Number of Power Supply Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

SKU

string

OA,iLO

The blade's part number

HPE Blade

Details

Serial Number

string

OA,iLO

Serial Number of the blade.

HPE Blade

Details

System Zone Temperature Sensors Above Caution

integer

OA

Number of System Zone Temperature Sensors reported by the blade with values greater than the caution threshold

HPE Blade

Details

System Zone Temperature Sensors Above Critical

integer

OA

Number of System Zone Temperature Sensors reported by the blade with values greater than the critical threshold

HPE Blade

Details

Virtual Fan

integer

OA

The blade's virtual fan usage

HPE Blade

Details

Hostname

string

OA

The blade's hostname

HPE Blade

General

Serial Number (Deprecated)

string

iLO

The blade serial number.

HPE Blade

General

UUID

string

iLO

The universal unique identifier for this blade.

HPE Blade

General

Hostname

string

iLO

The hostname of this blade.

HPE Blade

General

Manufacturer (Deprecated)

string

iLO

The manufacturer or OEM of this blade.

HPE Blade

General

Model

string

iLO

The model information that the manufacturer uses to refer to this blade.

HPE Blade

General

SKU (Deprecated)

string

iLO

SKU for the blade.

HPE Blade

General

Asset Tag

string

iLO

A user-definable tag that is used to track this blade for inventory or other client purposes.

HPE Blade

Firmware

BIOS Version (Deprecated)

string

iLO

The version of the blade BIOS or primary blade firmware.

HPE Blade

Firmware

Platform Definition Firmware Version

string

iLO

Platform Definition Table version.

HPE Blade

Firmware

Power Management Controller Firmware Version

string

iLO

The Power Management Microcontroller firmware version.

HPE Blade

Firmware

Power Management Controller Bootloader Firmware Version

string

iLO

The Power Management Microcontroller firmware bootloader version.

HPE Blade

Firmware

SAS PLD Firmware Version

string

iLO

SAS Programmable Logic Device version.

HPE Blade

Firmware

SPS Firmware Version

string

iLO

SPS Firmware version

HPE Blade

Firmware

System PLD Firmware Version

string

iLO

The firmware version of the CPLD.

HPE Blade

Processor

Core Count

integer

iLO

The number of processor cores in the blade.

HPE Blade

Processor

Processor Count

integer

iLO

The number of processors in the blade.

HPE Blade

Processor

Processor Model

string

iLO

The processor model for the primary or majority of processors in this blade.

HPE Blade

Processor

Processor Health

string

iLO

This represents the health state of the processors in the absence of its dependent resources.

HPE Blade

Network Adapter

Critical Network Adapter Health

integer

iLO

Number of Network Adapters with Health Critical.

HPE Blade

Network Adapter

Warning Network Adapter Health

integer

iLO

Number of Network Adapters with Health Warning.

HPE Blade

Network Adapter

OK Network Adapter Health

integer

iLO

Number of Network Adapters with Health OK.

HPE Blade

Power

Power State

string

iLO

This is the current power state of the blade.

HPE Blade

Power

Power Capacity

double

iLO

The total amount of power allocated to the blade.

HPE Blade

Memory

Memory Health

string

iLO

This represents the health state of the memory in the absence of its dependent resources.

HPE Blade

Memory

Total Memory

double

iLO

The total amount of memory in the blade.

HPE Blade

Memory

Memory

integer

OA

Memory on the blade

HPE Blade

Status

State

string

iLO

This indicates the known state of the blade, such as if it is enabled.

HPE Blade

Status

Health

string

iLO, OA

This represents the health state of this blade in the absence of its dependent resources.

HPE Blade

Status

Cooling Status

string

OA

The blade's cooling status

HPE Blade

Status

Device Degraded Status

string

OA

The blade's device degraded status

HPE Blade

Status

Device Failure Status

string

OA

The blade's device failure status

HPE Blade

Status

I/O Configuration Status

string

OA

The blade's I/O configuration status

HPE Blade

Status

Internal Data Status

string

OA

The blade's internal data status

HPE Blade

Status

Location Status

string

OA

The blade's location status

HPE Blade

Status

Management Processor Status

string

OA,iLO

Status of the Management Processor on the blade

HPE Blade

Status

Mezzanine Card Status

string

OA

The blade's mezzanine card status

HPE Blade

Status

Power State

string

OA

The on/off power state of the blade

HPE Blade

Status

Power Status

string

OA

Power status of the blade

HPE Blade

Status

VCM Configured Status

string

OA

The blade's VCM configured status

HPE Blade

Status

iLO Network Status

string

OA

The blade's iLO network status

HPE Network Adapter

Relationships

Blade Parent

string

iLO

The blade this network adapter is on.

HPE Network Adapter

Relationships

Rack Parent

string

iLO

The rack system this network adapter is on.

HPE Network Adapter

Relationships

Port Child

string

iLO

Port that this network adapter has.

HPE Network Adapter

General

IP Addresses

string

iLO

The IP addresses of the ports on the network adapter.

HPE Network Adapter

General

Serial Number

string

iLO

The device serial number.

HPE Network Adapter

General

Part Number

string

iLO

The device part number.

HPE Network Adapter

Firmware

Firmware Version

string

iLO

This string represents the version of the firmware image.

HPE Network Adapter

Status

State

string

iLO

This indicates the known state of the port, such as if it is enabled.

HPE Network Adapter

Status

Health

string

iLO

This represents the health state of this resource in the absence of its dependent resources.

HPE Network Adapter

Port Health

State

string

iLO

This indicates the known state of the port, such as if it is enabled.

HPE Network Adapter

Port Health

Critical Port Health

integer

iLO

Number of Ports with Health Critical.

HPE Network Adapter

Port Health

Warning Port Health

integer

iLO

Number of Ports with Health Warning.

HPE Network Adapter

Port Health

OK Port Health

integer

iLO

Number of Ports with Health OK.

HPE Network Adapter

Performance

Bad Receives

double

iLO

A count of frames that were received by the adapter but which had an error. This counter is the sum of mib items cpqNicIfPhysAdapterAlignmentErrors, cpqNicIfPhysAdapterFCSErrors, cpqNicIfPhysAdapterFrameTooLongs, and cpqNicIfPhysAdapterInternalMacReceiveErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action.

HPE Network Adapter

Performance

Bad Transmits

double

iLO

A count of frames that were not transmitted by the adapter because of an error. This counter is the sum of MIB items cpqNicIfPhysAdapterDeferredTransmissions, cpqNicIfPhysAdapterLateCollisions, cpqNicIfPhysAdapterExcessiveCollisions, cpqNicIfPhysAdapterCarrierSenseErrors, and cpqNicIfPhysAdapterInternalMacTransmitErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action.

HPE Network Adapter

Performance

Good Receives

double

iLO

A count of frames successfully received by the physical adapter.

HPE Network Adapter

Performance

Good Transmits

double

iLO

A count of frames successfully transmitted by the physical adapter.

HPE Port

Relationships

Network Adapter Parent

string

iLO

The network adapter this port is on.

HPE Port

Details

Bay

integer

OA

Bay the port is in.

HPE Port

Details

Bay Port Number

integer

OA

Bay port number assigned to the port.

HPE Port

Details

Mezzanine Device

string

OA

Mezzanine device for the port.

HPE Port

Details

Mezzanine Slot

string

OA

Mezzanine slot of the port.

HPE Port

General

MAC Address

string

iLO

The port MAC address.

HPE Port

General

Full Duplex

string

iLO

Full-duplex data transmission means that data can be transmitted in both directions on a signal carrier at the same time.

HPE Port

General

IPv4 Address

string

iLO

This is the IPv4 Address.

HPE Port

General

IPv6 Address

string

iLO

This is the IPv6 Address.

HPE Port

Performance

Bad Receives

double

iLO

A count of frames that were received by the adapter but which had an error. This counter is the sum of mib items cpqNicIfPhysAdapterAlignmentErrors, cpqNicIfPhysAdapterFCSErrors, cpqNicIfPhysAdapterFrameTooLongs, and cpqNicIfPhysAdapterInternalMacReceiveErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action.

HPE Port

Performance

Bad Transmits

double

iLO

A count of frames that were not transmitted by the adapter because of an error. This counter is the sum of MIB items cpqNicIfPhysAdapterDeferredTransmissions, cpqNicIfPhysAdapterLateCollisions, cpqNicIfPhysAdapterExcessiveCollisions, cpqNicIfPhysAdapterCarrierSenseErrors, and cpqNicIfPhysAdapterInternalMacTransmitErrors. If this counter increments frequently, check the more detailed error statistics and take appropriate action.

HPE Port

Performance

Good Receives

double

iLO

A count of frames successfully received by the physical adapter.

HPE Port

Performance

Good Transmits

double

iLO

A count of frames successfully transmitted by the physical adapter.

HPE Port

Performance

Speed

double

iLO

An estimate of the interface's current bandwidth For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth.

HPE Port

Status

State

string

iLO

This indicates the known state of the port, such as if it is enabled.

HPE Port

Status

Health

string

iLO

This represents the health state of this resource in the absence of its dependent resources.

HPE Port

Status

Status

string

OA

Status of the port

HPE Chassis

Relationships

Enclosure Parent

string

iLO

Enclosure this chassis is on.

HPE Chassis

Relationships

Power Supply Child

string

iLO

Power Supply this chassis has.

HPE Chassis

Relationships

Blade Child

string

iLO

Blade this chassis has.

HPE Chassis

Relationships

Fan Child

string

iLO

Fan this chassis has.

HPE Chassis

Fan Health

Critical Fan Health

integer

iLO

Number of Fans with Health Critical.

HPE Chassis

Fan Health

Warning Fan Health

integer

iLO

Number of Fans with Health Warning.

HPE Chassis

Fan Health

OK Fan Health

integer

iLO

Number of Fans with Health OK.

HPE Chassis

Performance

Maximum Memory Temperature

double

iLO

The maximum memory temperature of the chassis.

HPE Chassis

Performance

Maximum CPU Temperature

double

iLO

The maximum cpu temperature of the chassis.

HPE Chassis

Performance

Average CPU Temperature

double

iLO

The average CPU temperature of the chassis.

HPE Chassis

Performance

Average Memory Temperature

double

iLO

The average memory temperature of the chassis.

HPE Chassis

General

Model

string

iLO

The chassis model number.

HPE Chassis

General

Serial Number

string

iLO

The chassis serial number.

HPE Chassis

General

Chassis Type

string

iLO

This property indicates the physical form factor type of this chassis.

HPE Chassis

General

Hostname

string

iLO

The hostname of this chassis.

HPE Chassis

General

Manufacturer

string

iLO

The chassis manufacturer.

HPE Chassis

General

UUID

string

iLO

The chassis UUID.

HPE Chassis

General

Name

string

iLO

The chassis name.

HPE Chassis

General

SKU

string

iLO

SKU for the chassis.

HPE Chassis

General

Version

string

iLO

The chassis version.

HPE Chassis

General

Asset Tag

string

iLO

The chassis user-assigned asset tag.

HPE Chassis

General

Consumed Height (Bays)

double

iLO

The number of enclosure bays this chassis consumes in height.

HPE Chassis

General

Consumed Width (Bays)

double

iLO

The number of enclosure bays this chassis consumes in width.

HPE Chassis

General

Bay Number

string

iLO

The position of the chassis inside an enclosure.

HPE Chassis

General

Height (U)

string

iLO

The chassis rack U height.

HPE Chassis

General

U Location

string

iLO

The chassis rack U location.

HPE Chassis

General

U Position

string

iLO

The chassis U position in the rack.

HPE Chassis

General

Rack Part Number

string

iLO

The chassis rack part number.

HPE Chassis

General

Rack Product Description

string

iLO

The chassis rack description.

HPE Chassis

Status

State

string

iLO

This indicates the known state of the chassis, such as if it is enabled.

HPE Chassis

Status

Health

string

iLO

This represents the health state of this chassis in the absence of its dependent resources.

HPE Chassis

Firmware

SAS PLD Firmware Version

string

iLO

The firmware version of the SAS controller.

HPE Chassis

Firmware

SPS Firmware Version

string

iLO

The SPS FW Version number, aka ME FW Version, AAAA.BBBB.CCCC.DDDD.E

HPE Chassis

Firmware

System PLD Firmware Version

string

iLO

The firmware version of the CPLD.

HPE Chassis

Firmware

Power Management Controller Firmware Version (Deprecated)

string

iLO

The firmware version of the Power Monitor.

HPE Chassis

Firmware

Power Management Controller Boot Loader Firmware Version

string

iLO

The firmware version of the Power Monitor boot loader.

HPE Chassis

Firmware

Platform Definition Firmware Version

string

iLO

The version of the Intelligent Platform Abstraction Data.

HPE Chassis

Power

Power Management Hardware Family

string

iLO

The family type of the Power Monitor hardware.

HPE Chassis

Power

Power Capacity

double

iLO

The total power (Watts) available to the chassis from all power supplies (adjusting for redundancy settings).

HPE Chassis

Power

Power Metrics Interval

double

iLO

The interval between power metric evaluation in minutes.

HPE Chassis

Power

Minimum Power Consumed

double

iLO

The minimum power consumed during the interval specified by IntervalInMin.

HPE Chassis

Power

Maximum Power Consumed

double

iLO

The maximum power consumed during the interval specified by IntervalInMin.

HPE Chassis

Power

Average Power Consumed

double

iLO

The average power consumed during the interval specified by IntervalInMin.

HPE Chassis

Power

Power Consumed

double

iLO

The latest observed power (Watts) being drawn by this chassis. The update interval may vary depending upon implementation but is usually measured in seconds.

HPE Rack

Relationships

Servers Parent

string

iLO

Servers container.

HPE Rack

Relationships

Enclosure Parent

string

iLO

Enclosure this rack is on.

HPE Rack

Relationships

Power Supply Child

string

iLO

Power Supply this rack has.

HPE Rack

Relationships

Network Adapter Child

string

iLO

Network adapter this rack has.

HPE Rack

Relationships

Fan Child

string

iLO

Fan this rack has.

HPE Rack

Relationships

Host System Parent

string

iLO

Host system parent.

HPE Rack

Network Adapter

Critical Network Adapter Health

integer

iLO

Number of Network Adapters with Health Critical.

HPE Rack

Network Adapter

Warning Network Adapter Health

integer

iLO

Number of Network Adapters with Health Warning.

HPE Rack

Network Adapter

OK Network Adapter Health

integer

iLO

Number of Network Adapters with Health OK.

HPE Rack

Fan Health

Critical Fan Health

integer

iLO

Number of Fans with Health Critical.

HPE Rack

Fan Health

Warning Fan Health

integer

iLO

Number of Fans with Health Warning.

HPE Rack

Fan Health

OK Fan Health

integer

iLO

Number of Fans with Health OK.

HPE Rack

Power Supply Health

Critical Power Supply Health

integer

iLO

Number of Power Supplys with Health Critical.

HPE Rack

Power Supply Health

Warning Power Supply Health

integer

iLO

Number of Power Supplys with Health Warning.

HPE Rack

Power Supply Health

OK Power Supply Health

integer

iLO

Number of Power Supplys with Health OK.

HPE Rack

Performance

Maximum Memory Temperature

double

iLO

The maximum memory temperature of the chassis.

HPE Rack

Performance

Maximum CPU Temperature

double

iLO

The maximum cpu temperature of the chassis.

HPE Rack

Performance

Average CPU Temperature

double

iLO

The average CPU temperature of the chassis.

HPE Rack

Performance

Average Memory Temperature

double

iLO

The average memory temperature of the chassis.

HPE Rack

General

Name

string

iLO

The rack name.

HPE Rack

General

Serial Number

string

iLO

The rack serial number.

HPE Rack

General

Chassis Type

string

iLO

This property indicates the physical form factor type of this rack.

HPE Rack

General

Hostname

string

iLO

The hostname of this rack.

HPE Rack

General

Manufacturer

string

iLO

The rack manufacturer.

HPE Rack

General

Model

string

iLO

The rack model number.

HPE Rack

General

SKU

string

iLO

SKU for the rack.

HPE Rack

General

Version

string

iLO

The rack version.

HPE Rack

General

Asset Tag

string

iLO

The rack user-assigned asset tag.

HPE Rack

General

UUID

string

iLO

The rack UUID provided by SMBIOS.

HPE Rack

General

Consumed Height (Bays)

string

iLO

The number of enclosure bays this rack consumes in height.

HPE Rack

General

Consumed Width (Bays)

string

iLO

The number of enclosure bays this rack consumes in width.

HPE Rack

General

Bay Number

string

iLO

The position of the rack inside an enclosure.

HPE Rack

General

Height (U)

string

iLO

The rack U height.

HPE Rack

General

U Location

string

iLO

The rack U location.

HPE Rack

General

U Position

string

iLO

The rack U position in the rack.

HPE Rack

General

Enclosure

string

iLO

The name of the rack enclosure.

HPE Rack

Status

State

string

iLO

This indicates the known state of the rack, such as if it is enabled.

HPE Rack

Status

Health

string

iLO

This represents the health state of this rack in the absence of its dependent resources.

HPE Rack

Firmware

BIOS Version

string

iLO

The version of the blade BIOS or primary blade firmware.

HPE Rack

Firmware

SAS PLD Firmware Version

string

iLO

The firmware version of the SAS controller.

HPE Rack

Firmware

SPS Firmware Version

string

iLO

The SPS FW Version number, aka ME FW Version, AAAA.BBBB.CCCC.DDDD.E

HPE Rack

Firmware

System PLD Firmware Version

string

iLO

The firmware version of the CPLD.

HPE Rack

Firmware

Power Management Controller Firmware Version

string

iLO

The firmware version of the Power Monitor.

HPE Rack

Firmware

Power Management Controller Boot Loader Firmware Version

string

iLO

The firmware version of the Power Monitor boot loader.

HPE Rack

Firmware

Platform Definition Firmware Version

string

iLO

The version of the Intelligent Platform Abstraction Data.

HPE Rack

Power

Power Management Hardware

string

iLO

The family type of the Power Monitor hardware.

HPE Rack

Power

Power State

string

iLO

This is the current power state of the blade.

HPE Rack

Power

Power Limit

double

iLO

The total amount of power allocated to the blade.

HPE Rack

Power

Power Capacity

double

iLO

The total power (Watts) available to the chassis from all power supplies (adjusting for redundancy settings).

HPE Rack

Power

Power Metrics Interval

double

iLO

The interval between power metric evaluation in minutes.

HPE Rack

Power

Minimum Power Consumed

double

iLO

The minimum power consumed during the interval specified by IntervalInMin.

HPE Rack

Power

Maximum Power Consumed

double

iLO

The maximum power consumed during the interval specified by IntervalInMin.

HPE Rack

Power

Average Power Consumed

double

iLO

The average power consumed during the interval specified by IntervalInMin.

HPE Rack

Power

Power Consumed

double

iLO

The latest observed power (Watts) being drawn by this chassis. The update interval may vary depending upon implementation but is usually measured in seconds.

HPE Rack

Processor

Core Count

integer

iLO

The number of processor cores in the rack system.

HPE Rack

Processor

Processor Count

integer

iLO

The number of processors in the rack system.

HPE Rack

Processor

Processor Model

string

iLO

The processor model for the primary or majority of processors in this rack system.

HPE Rack

Processor

Processor Health

string

iLO

This represents the health state of the processors in the absence of its dependent resources.

HPE Rack

Memory

Memory Health

string

iLO

This represents the health state of the memory in the absence of its dependent resources.

HPE Rack

Memory

Total Memory

double

iLO

The total amount of memory in the rack system.

HPE Power Supply

Relationships

Chassis Parent

string

iLO

Chassis this power supply is on.

HPE Power Supply

Relationships

Rack Parent

string

iLO

Rack this power supply is on.

HPE Power Supply

Relationships

Enclosure Parents

string

OA

List of parent Enclosure resources

HPE Power Supply

General

Serial Number

string

iLO

The serial number for this Power Supply

HPE Power Supply

General

Bay Number

string

iLO

The power supply bay number.

HPE Power Supply

General

Spare Part Number

string

iLO

The part number for this Power Supply

HPE Power Supply

General

Model

string

iLO

The model number for this Power Supply.

HPE Power Supply

General

Type

string

iLO

The Power Supply type (AC or DC).

HPE Power Supply

General

Hotplug Capable

string

iLO

If true, this power supply (and power supply bay) is capable of being hot-plugged.

HPE Power Supply

Firmware

Firmware Version

string

iLO

The firmware version for this Power Supply.

HPE Power Supply

Details

Current Power Output

integer

OA

Current Power Output

HPE Power Supply

Details

Output Capacity

integer

OA

Output Capacity

HPE Power Supply

Details

Part Number

string

OA

Part Number

HPE Power Supply

Details

Power Supply Number

string

OA

Power Supply Number.

HPE Power Supply

Details

Product Name

string

OA

Power Supply Product Name.

HPE Power Supply

Details

Spare Part Number

string

iLO, OA

Spare Part Number

HPE Power Supply

Details

Version

string

OA

Product Version

HPE Power Supply

Status

State

string

iLO

This indicates the known state of the power supply, such as if it is enabled.

HPE Power Supply

Status

Health

string

iLO

This represents the health state of this power supply in the absence of its dependent resources.

HPE Power Supply

Status

Status

string

OA

This indicates the known status of the power supply.

HPE Power Supply

Status

AC Input Status

string

OA

AC Input Status

HPE Power Supply

Status

Device Failure Status

string

OA

Device Failure Status

HPE Power Supply

Status

Internal Data Status

string

OA

Internal Data Status

HPE Power Supply

Status

Power Cord Status

string

OA

Power Cord Status

HPE Power Supply

Performance

Power Capacity

double

iLO

The maximum capacity of this Power Supply.

HPE Power Supply

Performance

Average Power Output

double

iLO

The average power output of this Power Supply.

HPE Fan

Relationships

Chassis Parent

string

iLO

Chassis this fan is on.

HPE Fan

Relationships

Rack Parent

string

iLO

Rack this fan is on.

HPE Fan

Details

Maximum speed

integer

OA

Maximum speed of the fan

HPE Fan

Details

Minimum speed

integer

OA

Minimum speed of the fan

HPE Fan

Details

Part Number

string

OA

HPE assigned part number

HPE Fan

Details

Power Consumed

integer

OA

Power Consumed by the fan

HPE Fan

Details

Product Name

string

OA

HPE assigned product name

HPE Fan

Details

Spare Part Number

string

OA

HPE assigned spare part number

HPE Fan

Details

Percent of Maximum Speed

integer

OA

Speed as a percent of Maximum speed

HPE Fan

Details

Version

string

OA

HPE assigned Version

HPE Fan

General

Chassis Serial Number

string

iLO

The serial number of the chassis this fan is on.

HPE Fan

General

Name

string

iLO

The name of the fan sensor.

HPE Fan

General

Fan Location

string

iLO

The area or device to which this fan is located.

HPE Fan

Status

State

string

iLO

The state of the fan.

HPE Fan

Status

Health

string

iLO

The health of the fan.

HPE Fan

Status

Device Degraded Status

string

OA

Device Degraded Diagnostic Status of the fan

HPE Fan

Status

Device Failure Status

string

OA

Device Failure Diagnostic Status of the fan

HPE Fan

Status

Internal Data Status

string

OA

Internal Data Diagnostic Status of the fan

HPE Fan

Status

Location Status

string

OA

Location Diagnostic Status of the fan

HPE Fan

Status

Missing Device Status

string

OA

Missing Device Diagnostic Status of the fan

HPE Fan

Status

Status

string

OA

Status of the fan

HPE Fan

Performance

Current Utilization (%)

double

iLO

The current utilization (% of max speed) of the fan.

HPE Fan

Performance

Current Speed (RPM)

double

iLO

The current speed of the fan.

HPE Interconnect

Network

Average Received Data

float

VCM

Average Received Data

HPE Interconnect

Network

Average Received Non Unicast Packets

float

VCM

Average Received Non Unicast Packets

HPE Interconnect

Network

Average Received Packets

float

VCM

Average Received Packets

HPE Interconnect

Network

Average Transmitted Data

float

VCM

Average Transmitted Data

HPE Interconnect

Network

Average Transmitted Non Unicast Packets

float

VCM

Average Transmitted Non Unicast Packets

HPE Interconnect

Network

Average Transmitted Packets

float

VCM

Average Transmitted Packets

HPE Interconnect

Network

Total Received Data

integer

VCM

Total Received Data

HPE Interconnect

Network

Total Received Non Unicast Packets

integer

VCM

Total Received Non Unicast Packets

HPE Interconnect

Network

Total Received Packets

integer

VCM

Total Received Packets

HPE Interconnect

Network

Total Transmitted Data

integer

VCM

Total Transmitted Data

HPE Interconnect

Network

Total Transmitted Non Unicast Packets

integer

VCM

Total Transmitted Non Unicast Packets

HPE Interconnect

Network

Total Transmitted Packets

integer

VCM

Total Transmitted Packets

HPE Interconnect

Network

Average TCP/IP Discarded Datagrams Received

float

VCM

Average Discarded Packets Received

HPE Interconnect

Network

Total TCP/IP Discarded Datagrams Received

integer

VCM

Total Discarded Packets Received

HPE Interconnect

Network

Average TCP/IP Forwarded Datagrams

float

VCM

Average Forwarded datagrams

HPE Interconnect

Network

Total TCP/IP Forwarded Datagrams

integer

VCM

Total Forwarded datagrams

HPE Interconnect

Network

Average TCP/IP Received Datagrams

float

VCM

Average Received Datagrams

HPE Interconnect

Network

Total TCP/IP Received Datagrams

integer

VCM

Total Received Datagrams

HPE Interconnect

Network

Average TCP/IP Discarded Inbound Packets

float

VCM

Average Discarded Inbound Packets

HPE Interconnect

Network

Total TCP/IP Discarded Inbound Packets

integer

VCM

Total Discarded Inbound Packets

HPE Interconnect

Network

Average TCP/IP Inbound Error Packets

float

VCM

Average Inbound Packets Undeliverable due to Errors

HPE Interconnect

Network

Total TCP/IP Inbound Error Packets

integer

VCM

Total Inbound Packets Undeliverable due to Errors

HPE Interconnect

Network

Average TCP/IP Header Error Datagrams Received

float

VCM

Average Header Error Datagrams Received

HPE Interconnect

Network

Total TCP/IP Header Error Datagrams Received

integer

VCM

Total Header Error Datagrams Received

HPE Interconnect

Network

Average TCP/IP Inbound Non-Unicast Packets

float

VCM

Average Non-Unicast Packets received

HPE Interconnect

Network

Total TCP/IP Inbound Non-Unicast Packets

integer

VCM

Total Non-Unicast Packets received

HPE Interconnect

Network

Average TCP/IP Total Octets Received

float

VCM

Average Total Octets Received

HPE Interconnect

Network

Total TCP/IP Total Octets Received

integer

VCM

Total Total Octets Received

HPE Interconnect

Network

Average TCP/IP Unicast Packets Received

float

VCM

Average Total Octets Received

HPE Interconnect

Network

Total TCP/IP Unicast Packets Received

integer

VCM

Total Total Octets Received

HPE Interconnect

Network

Average TCP/IP Unknown Protocols

float

VCM

Average Inbound packets discarded because of an unknown or unsupported protocol

HPE Interconnect

Network

Total TCP/IP Unknown Protocols

integer

VCM

Total Inbound packets discarded because of an unknown or unsupported protocol

HPE Interconnect

Network

Average TCP/IP Discarded Outbound Packets

float

VCM

Average Discarded outbound packets

HPE Interconnect

Network

Total TCP/IP Discarded Outbound Packets

integer

VCM

Total Discarded outbound packets

HPE Interconnect

Network

Average TCP/IP Outbound Error Packets

float

VCM

Average Outbound Packets Undeliverable due to Errors

HPE Interconnect

Network

Total TCP/IP Outbound Error Packets

integer

VCM

Total Outbound Packets Undeliverable due to Errors

HPE Interconnect

Network

Average TCP/IP Outbound Non-Unicast Packets

float

VCM

Average Outbound Non-Unicast Packets

HPE Interconnect

Network

Total TCP/IP Outbound Non-Unicast Packets

integer

VCM

Total Outbound Non-Unicast Packets

HPE Interconnect

Network

Average TCP/IP Total Octets Sent

float

VCM

Average Total Octets Sent

HPE Interconnect

Network

Total TCP/IP Total Octets Sent

integer

VCM

Total Total Octets Sent

HPE Interconnect

Network

Average TCP/IP Packet Outbound Queue Length

float

VCM

Average Packet Outbound Queue Length

HPE Interconnect

Network

Total TCP/IP Packet Outbound Queue Length

integer

VCM

Total Packet Outbound Queue Length

HPE Interconnect

Network

Average TCP/IP Unicast Packets Delivered

float

VCM

Average Unicast Packets Delivered

HPE Interconnect

Network

Total TCP/IP Unicast Packets Delivered

integer

VCM

Total Unicast Packets Delivered

HPE Interconnect

Relationships

Enclosure Parent

string

VCM

List of parent Enclosure resources

HPE Interconnect

Relationships

Servers Parent

string

VCM

List of parent server tag resources

HPE Interconnect

Relationships

Interconnect Port Children

string

VCM

List of child Interconnect Port resources

HPE Interconnect

Details

VCM Host

string

VCM

VCM Host

HPE Interconnect

Details

Bay

string

VCM

Bay

HPE Interconnect

Details

Enclosure

string

VCM

Enclosure

HPE Interconnect

Details

Firmware Version

string

VCM

Firmware Version

HPE Interconnect

Details

Hostname

string

VCM

Hostname

HPE Interconnect

Details

IP Address

string

VCM

IP Address

HPE Interconnect

Details

IPv6 Address

string

VCM

IPv6 Address

HPE Interconnect

Details

MAC Address

string

VCM

MAC Address

HPE Interconnect

Details

Manufacturer

string

VCM

Manufacturer

HPE Interconnect

Details

Node WWN

string

VCM

Node WWN

HPE Interconnect

Details

Part Number

string

VCM

Part Number

HPE Interconnect

Details

Product Name

string

VCM

Product Name

HPE Interconnect

Details

Rack Name

string

VCM

Rack Name

HPE Interconnect

Details

Role

string

VCM

Role

HPE Interconnect

Details

Serial Number

string

VCM

Serial Number

HPE Interconnect

Details

Spare Part Number

string

VCM

Spare Part Number

HPE Interconnect

Details

Type

string

VCM

Type

HPE Interconnect

Details

UID

string

VCM

UID

HPE Interconnect

Status

Status

string

VCM

Status

HPE Interconnect

Status

Status Cause

string

VCM

Status Cause

HPE Interconnect

Status

Root Cause

string

VCM

Root Cause

HPE Interconnect

Status

Power Status

string

VCM

Power Status

HPE Interconnect

Status

OA Status

string

VCM

OA Status

HPE Interconnect

Status

Comm Status

string

VCM

Comm Status

HPE Interconnect Port

Details

Autonegotiate

string

VCM

Autonegotiate

HPE Interconnect Port

Details

Connected From

string

VCM

Connected From

HPE Interconnect Port

Details

Connected To

string

VCM

Connected To

HPE Interconnect Port

Details

Enclosure

string

VCM

Enclosure

HPE Interconnect Port

Details

LAG ID

string

VCM

LAG ID

HPE Interconnect Port

Details

Label

string

VCM

Label

HPE Interconnect Port

Details

Paired With

string

VCM

Paired With

HPE Interconnect Port

Details

Speed

string

VCM

Speed

HPE Interconnect Port

Details

Type

string

VCM

Type

HPE Interconnect Port

Details

Used By

string

VCM

Used By

HPE Interconnect Port

Network

Received Frames

float

VCM

Frames received for bridging functions

HPE Interconnect Port

Network

Sent Frames

float

VCM

Frames sent for bridging functions

HPE Interconnect Port

Network

Discards

float

VCM

Frames discarded for bridging functions

HPE Interconnect Port

Network

Discards Due To Delay

float

VCM

Frames discarded due to excessive transit delay through the bridge for bridging functions

HPE Interconnect Port

Network

Discards Due To Size

float

VCM

Frames discarded due to excessive size for bridging functions

HPE Interconnect Port

Network

Interface Broadcast Received

float

VCM

Total broadcast packets received for this sub-layer to a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Broadcast Sent

float

VCM

Total broadcast packets requested by a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Multicast Received

float

VCM

Total multicast packets received for this sub-layer to a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Multicast Sent

float

VCM

Total multicast packets requested by a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Octets Received

float

VCM

Total octets received for this interface.

HPE Interconnect Port

Network

Interface Octets Sent

float

VCM

Total octets requested by a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Unicast Received

float

VCM

Total unicast packets received for this sub-layer to a higher (sub-)layer.

HPE Interconnect Port

Network

Interface Unicast Sent

float

VCM

Total unicast packets requested by a higher (sub-)layer.

HPE Interconnect Port

Network

Received Data

integer

VCM

Received Data

HPE Interconnect Port

Network

Received Non Unicast Packets

integer

VCM

Received Non Unicast Packets

HPE Interconnect Port

Network

Received Packets

integer

VCM

Received Packets

HPE Interconnect Port

Network

Remote Broadcast Packets Received

float

VCM

Total good broadcast packets received

HPE Interconnect Port

Network

Remote Collisions

float

VCM

Collisions on this ethernet segment

HPE Interconnect Port

Network

Remote Drop Events

float

VCM

Total events in which packets were dropped due to lack of resources.

HPE Interconnect Port

Network

Remote Fragments

float

VCM

Total Packets received that were less than 64 octets in length.

HPE Interconnect Port

Network

Remote Jabbers

float

VCM

Total Packets received that were greater than 1518 octets in length.

HPE Interconnect Port

Network

Remote Multicast

float

VCM

Total Packets received that were directed to a multicast address.

HPE Interconnect Port

Network

Remote Octets

float

VCM

Total octets of data received on the network.

HPE Interconnect Port

Network

Remote Oversize Packets

float

VCM

Total packets longer than 1518 received on the network.

HPE Interconnect Port

Network

Remote Packets

float

VCM

Total packets received on the network.

HPE Interconnect Port

Network

Remote Packets Received without Errors

float

VCM

Total packets with no errors received on the network.

HPE Interconnect Port

Network

Remote Packets Size 1024 to 1418

float

VCM

Total packets between 1024 and 1418 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Size 128 to 255

float

VCM

Total packets between 128 and 255 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Size 256 to 511

float

VCM

Total packets between 256 and 511 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Size 512 to 1023

float

VCM

Total packets between 512 and 1023 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Size 64

float

VCM

Total packets sized 54 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Size 65 to 127

float

VCM

Total packets between 65 and 127 octets received on the network.

HPE Interconnect Port

Network

Remote Packets Transmitted without Errors

float

VCM

Total packets with no errors transmitted on the network.

HPE Interconnect Port

Network

Remote Received CRC Alignment Errors

float

VCM

Total packets received that had an alignment error

HPE Interconnect Port

Network

Remote Undersized Packets

float

VCM

Total packets less than 64 octets in size received on the network.

HPE Interconnect Port

Network

TCP/IP Discarded Datagrams Received

float

VCM

Discarded Packets Received

HPE Interconnect Port

Network

TCP/IP Discarded Inbound Packets

float

VCM

Discarded Inbound Packets

HPE Interconnect Port

Network

TCP/IP Discarded Outbound Packets

float

VCM

Discarded outbound packets

HPE Interconnect Port

Network

TCP/IP Forwarded Datagrams

float

VCM

Forwarded datagrams

HPE Interconnect Port

Network

TCP/IP Header Error Datagrams Received

float

VCM

Header Error Datagrams Received

HPE Interconnect Port

Network

TCP/IP Inbound Error Packets

float

VCM

Inbound Packets Undeliverable due to Errors

HPE Interconnect Port

Network

TCP/IP Inbound Non-Unicast Packets

float

VCM

Non-Unicast Packets received

HPE Interconnect Port

Network

TCP/IP Outbound Error Packets

float

VCM

Outbound Packets Undeliverable due to Errors

HPE Interconnect Port

Network

TCP/IP Outbound Non-Unicast Packets

float

VCM

Outbound Non-Unicast Packets

HPE Interconnect Port

Network

TCP/IP Packet Outbound Queue Length

integer

VCM

Packet Outbound Queue Length

HPE Interconnect Port

Network

TCP/IP Received Datagrams

float

VCM

Received Datagrams

HPE Interconnect Port

Network

TCP/IP Total Octets Received

float

VCM

Total Octets Received

HPE Interconnect Port

Network

TCP/IP Total Octets Sent

float

VCM

Total Octets Sent

HPE Interconnect Port

Network

TCP/IP Unicast Packets Delivered

float

VCM

Unicast Packets Delivered

HPE Interconnect Port

Network

TCP/IP Unicast Packets Received

float

VCM

Total Octets Received

HPE Interconnect Port

Network

TCP/IP Unknown Protocols

float

VCM

Inbound packets discarded because of an unknown or unsupported protocol

HPE Interconnect Port

Network

Transmitted Data

integer

VCM

Transmitted Data

HPE Interconnect Port

Network

Transmitted Non Unicast Packets

integer

VCM

Transmitted Non Unicast Packets

HPE Interconnect Port

Network

Transmitted Packets

integer

VCM

Transmitted Packets

HPE Interconnect Port

Relationships

Interconnect Parents

string

VCM

List of parent Interconnect resources

HPE Interconnect Port

Relationships

Port Parents

string

VCM

List of parent Port resources

HPE Interconnect Port

Relationships

Cisco Networking Switch Parent

string

iLO

Cisco Networking Switch parent.

HPE Interconnect Port

Status

PID LED State

string

VCM

PID LED State

HPE Interconnect Port

Status

Status

string

VCM

Status