This reference includes examples for the syntax information for the flow-sync command.
| Command | Description |
|---|---|
| flow-sync | Sync flows from one VMware Aria Operations for Networks collector to another VMware Aria Operations for Networks collector.
Note: You must start the receiver first and then run sync on the sender side.
|
| Flag | Description |
|---|---|
| status | Shows flow sync status. |
| stop | Stops sending flows to an VMware Aria Operations for Networks collector or receiving flows from an VMware Aria Operations for Networks collector. |
| start | Starts sending/receiving flows to/form a VMware Aria Operations for Networks collector. |
| logs | Shows flow logs. |
| Command |
|---|
| flow-sync start receiver --sender-ip=<IP Address> For example: flow-sync start receiver --sender-ip=10.79.41.165 |
| flow-sync start sender --secret <secret code> For example: flow-sync start sender --secret MTAuNzkuNDEuMTY1OjE.....EtFWS0tLS0t |
| flow-sync status |
| flow-sync stop |
| flow-sync logs |