VMware Aria Operations for Networks raises several self-computed NSX-T alerts. In addition, all NSX-T generated system alerts (for NSX-T versions 2.2 to 2.5) and NSX-T Alarms (for NSX-T version 3.0 onwards) are also visible in VMware Aria Operations for Networks.

Note: Starting from 6.3 release, a few events are optimized for quick notification and are delivered under 5 minutes. See the Optimized for quick notification column in the table.
Table 1. VMware Aria Operations for Networks Computed NSX-T Events
OID Event Name Default Severity UI Name Description Optimized for quick notification?
1.3.6.1.4.1.6876.100.1.0.40000 SwitchPortRxNetworkUsageThresholdExceededEvent Warning PNIC Rx Network Utilization is high PNIC utilization exceeds the threshold value of 75%. No
1.3.6.1.4.1.6876.100.1.0.40001 vmwCriticalHostNotAccessibleEvent Critical Host with Infrastructure VMs cannot be accessed Host with Infrastructure VMs cannot be accessed No
1.3.6.1.4.1.6876.100.1.0.40002 SwitchPortTxNetworkUsageThresholdExceededEvent Warning PNIC Tx Network Utilization is high PNIC utilization exceeds the threshold value of 75%. No
1.3.6.1.4.1.6876.100.1.0.40003 SwitchPortRxNetworkUsageThresholdExceededCriticalEvent Critical PNIC Rx Network Utilization is high PNIC utilization exceeds the threshold value of 90%. No
1.3.6.1.4.1.6876.100.1.0.40004 SwitchPortTxNetworkUsageThresholdExceededCriticalEvent Critical PNIC Tx Network Utilization is high PNIC utilization exceeds the threshold value of 90%. No
1.3.6.1.4.1.6876.100.1.0.40005 ManagementHostHighCPUUsageEvent Warning Management Host CPU Usage Event Host CPU utilization exceeds the threshold value of 75%. No
1.3.6.1.4.1.6876.100.1.0.40006 ManagementHostHighCPUUsageCriticalEvent Critical Management Host CPU Usage Critical Event Host CPU utilization exceeds the threshold value of 90%. No
1.3.6.1.4.1.6876.100.1.0.40007 HostUnHealthyEvent Critical Host is not healthy Host is not healthy No
1.3.6.1.4.1.6876.100.1.0.40008 FileSystem Disk Available of NSX Controller is Low Critical FileSystem Disk Available of NSX Controller is Low NSX Controller file system disk available percentage less than threshold value. No
1.3.6.1.4.1.6876.100.1.0.40011 EdgeVmVnicRxPacketDropEvent Critical Receive packets are getting dropped on the VNIC of Edge VM. Packets are getting dropped on the VNIC of Edge VM. This may impact the network traffic related to management nodes. No
1.3.6.1.4.1.6876.100.1.0.40012 EdgeVmVnicTxPacketDropEvent Critical Transmit packets are getting dropped on the VNIC of Edge VM. Packets are getting dropped on the VNIC of Edge VM. This may impact the network traffic related to management nodes. No
1.3.6.1.4.1.6876.100.1.0.40013 ManagementHostPnicRxPacketDropEvent Critical Receive packets are getting dropped on the PNIC of the management host. Packets are getting dropped on the pNIC of the management host. This may impact the network traffic related to management nodes. No
1.3.6.1.4.1.6876.100.1.0.40014 ManagementHostPnicTxPacketDropEvent Critical Transmit packets are getting dropped on the PNIC of the management host. Packets are getting dropped on the pNIC of the management host. This may impact the network traffic related to management nodes. No
1.3.6.1.4.1.6876.100.1.0.80205 NSXTNoUplinkConnectivityEvent Warning NSX-T Tier-1 logical router disconnect event NSX-T Tier-1 logical router is disconnected from Tier-0 router. Networks under this router are not reachable from outside and vice versa. No
1.3.6.1.4.1.6876.100.1.0.80206 NSXTRoutingAdvertisementEvent Warning Routing advertisement deactivated Routing advertisement is deactivated for NSX-T Tier-1 logical router. Networks under this router are not reachable from outside. No
1.3.6.1.4.1.6876.100.1.0.80207 NSXTManagerConnectivityDownEvent Critical NSX-T Edge Node has no manager connectivity NSX-T Edge Node has lost manager connectivity. Yes
1.3.6.1.4.1.6876.100.1.0.80208 NSXTControllerConnectivityDegradedEvent Warning Controller connectivity degraded for NSX-T Edge Node NSX-T Edge Node is not able to communicate with one or more controllers. Yes
1.3.6.1.4.1.6876.100.1.0.80209 NSXTControllerConnectivityDownEvent Critical NSX-T Edge Node has no controller connectivity NSX-T Edge Node is not able to communicate with any of the controllers. Yes
1.3.6.1.4.1.6876.100.1.0.80210 NSXTMtuMismatchEvent Warning MTU mismatch between NSX-T Tier-0 and uplink switch/router The MTU configured on interfaces of Tier-0 logical router does not match with the interfaces of uplink switch/router from same L2 network. This can impact the network performance. No
1.3.6.1.4.1.6876.100.1.0.80211 NSXTExcludedVmFlowEvent Info One or More VMs excluded from NSX-T DFW Firewall. One or more VMs are not protected by NSX-T DFW firewall. VMware Aria Operations for Networks will not receive IPFIX flows for these VMs. No
1.3.6.1.4.1.6876.100.1.0.80212 NSXTDoubleVlanTaggingEvent Warning Uplink Vlan misconfiguration Communication is disrupted because VLAN on uplink port of Tier 0 router is different than VLAN on the external gateway. No
1.3.6.1.4.1.6876.100.1.0.80213 NSXTNoTzAttachedOnTnEvent Warning No transport zone is attached to the transport node. No transport zone attached to the transport node. VMs might lose connectivity because of this. No
1.3.6.1.4.1.6876.100.1.0.80214 NSXTVtepDeleteEvent Warning No VTEP available on the transport node. All vteps are deleted from the transport node. VMs might lose connectivity because of this. No
1.3.6.1.4.1.6876.100.1.0.80225 NSXTControllerNodeToControlClusterConnectivityEvent Critical NSX-T controller node has no control cluster connectivity NSX-T controller node has lost control cluster connectivity. Yes
1.3.6.1.4.1.6876.100.1.0.80226 NSXTControllerNodeToMgmtPlaneConnectivityEvent Critical NSX-T controller node has no management plane connectivity NSX-T controller node has lost management plane connectivity. Yes
1.3.6.1.4.1.6876.100.1.0.80227 NSXTMPNodeToMgmtClusterConnectivityEvent Critical NSX-T management node has no management cluster connectivity NSX-T management node has lost management cluster connectivity. Yes
1.3.6.1.4.1.6876.100.1.0.80246 NSXTHostNodeMgmtConnectivityStatusDownEvent Warning NSX-T Host Node has no manager connectivity Desynchronization between NSX Manager's State of connectivity with Host Transport Nodes Yes
1.3.6.1.4.1.6876.100.1.0.80247 NSXTEdgeNodeCtlrConnectivityStatusUnknownEvent Critical Controller connectivity for NSX-T Edge Node is Unknown. NSX-T Edge Node Controller connectivity is Unknown. Yes
1.3.6.1.4.1.6876.100.1.0.80248 NSXTHostNodeCtlrConnectivityStatusDownEvent Warning NSX-T Host Node has no controller connectivity NSX-T Host Node is not able to communicate with any of the controllers. No
1.3.6.1.4.1.6876.100.1.0.80249 NSXTHostNodeCtlrConnectivityStatusDegradedEvent Warning Controller connectivity degraded for NSX-T Host Node NSX-T Host Node is not able to to communicate with one or more controllers. No
1.3.6.1.4.1.6876.100.1.0.80250 NSXTHostNodeCtlrConnectivityStatusUnknownEvent Warning Controller connectivity for NSX-T Host Node is Unknown. NSX-T Host Node Controller connectivity is Unknown. No
1.3.6.1.4.1.6876.100.1.0.80228 NSXTHostNodePnicStatusDownEvent Warning NSX-T Host Transport Node Pnic Status is 'Down'. NSX-T Host Transport Node Pnic Status is 'Down'. No
1.3.6.1.4.1.6876.100.1.0.80229 NSXTHostNodePnicStatusDegradedEvent Warning NSX-T Host Transport Node Pnic Status is 'Degraded' NSX-T Host Transport Node Pnic Status is 'Degraded'. No
1.3.6.1.4.1.6876.100.1.0.80230 NSXTHostNodePnicStatusUnknownEvent Warning NSX-T Host Transport Node Pnic Status is 'Unknown'. NSX-T Host Transport Node Pnic Status is 'Unknown'. No
1.3.6.1.4.1.6876.100.1.0.80237 NSXTEdgeNodePnicStatusDownEvent Critical NSX-T Edge Transport Node Pnic Status is 'Down'. NSX-T Edge Transport Node Pnic Status is 'Down'. Yes
1.3.6.1.4.1.6876.100.1.0.80238 NSXTEdgeNodePnicStatusDegradedEvent Critical NSX-T Edge Transport Node Pnic Status is 'Degraded'. NSX-T Edge Transport Node Pnic Status is 'Degraded'. Yes
1.3.6.1.4.1.6876.100.1.0.80239 NSXTEdgeNodePnicStatusUnknownEvent Critical NSX-T Edge Transport Node Pnic Status is 'Unknown'. NSX-T Edge Transport Node Pnic Status is 'Unknown'. Yes
1.3.6.1.4.1.6876.100.1.0.80231 NSXTHostNodeTunnelStatusDownEvent Warning NSX-T Host Transport Node Tunnel Status is 'Down'. NSX-T Host Transport Node Tunnel Status is 'Down'. No
1.3.6.1.4.1.6876.100.1.0.80232 NSXTHostNodeTunnelStatusDegradedEvent Warning NSX-T Host Transport Node Tunnel Status is 'Degraded'. NSX-T Host Transport Node Tunnel Status is 'Degraded'. No
1.3.6.1.4.1.6876.100.1.0.80233 NSXTHostNodeTunnelStatusUnknownEvent Warning NSX-T Host Transport Node Tunnel Status is 'Unknown'. NSX-T Host Transport Node Tunnel Status is 'Unknown'. No
1.3.6.1.4.1.6876.100.1.0.80240 NSXTEdgeNodeTunnelStatusDownEvent Critical NSX-T Edge Transport Node Tunnel Status is 'Down'. NSX-T Edge Transport Node Tunnel Status is 'Down'. Yes
1.3.6.1.4.1.6876.100.1.0.80241 NSXTEdgeNodeTunnelStatusDegradeEvent Critical NSX-T Edge Transport Node Tunnel Status is 'Degraded'. NSX-T Edge Transport Node Tunnel Status is 'Degraded'. Yes
1.3.6.1.4.1.6876.100.1.0.80242 NSXTEdgeNodeTunnelStatusUnknownEvent Critical NSX-T Edge Transport Node Tunnel Status is 'Unknown'. NSX-T Edge Transport Node Tunnel Status is 'Unknown'. Yes
1.3.6.1.4.1.6876.100.1.0.80234 NSXTHostNodeStatusDownEvent Warning NSX-T Host Transport Node Status is 'Down'. NSX-T Host Transport Node Status is 'Down'. No
1.3.6.1.4.1.6876.100.1.0.80235 NSXTHostNodeStatusDegradedEvent Warning NSX-T Host Transport Node Status is 'Degraded'. NSX-T Host Transport Node Status is 'Degraded'. No
1.3.6.1.4.1.6876.100.1.0.80236 NSXTHostNodeStatusUnknownEvent Warning NSX-T Host Transport Node Status is 'Unknown'. NSX-T Host Transport Node Status is 'Unknown'. No
1.3.6.1.4.1.6876.100.1.0.80243 NSXTEdgeNodeStatusDownEvent Critical NSX-T Edge Transport Node Status is 'Down'. NSX-T Edge Transport Node Status is 'Down'. Yes
1.3.6.1.4.1.6876.100.1.0.80244 NSXTEdgeNodeStatusDegradedEvent Critical NSX-T Edge Transport Node Status is 'Degraded'. NSX-T Edge Transport Node Status is 'Degraded'. Yes
1.3.6.1.4.1.6876.100.1.0.80245 NSXTEdgeNodeStatusUnknownEvent Critical NSX-T Edge Transport Node Status is 'Unknown'. NSX-T Edge Transport Node Status is 'Unknown'. Yes
1.3.6.1.4.1.6876.100.1.0.80252 NSXTLogicalSwitchAdminStatusDownEvent Warning NSX-T Logical Switch Admin Status is 'Down' NSX-T Logical Switch Admin Status is 'Down' No
1.3.6.1.4.1.6876.100.1.0.80253 NSXTLogicalPortOperationalStatusDownEvent Critical NSX-T Logical Port Operational Status is 'Down' NSX-T Logical Port Operational Status is 'Down'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. No
1.3.6.1.4.1.6876.100.1.0.80254 NSXTLogicalPortOperationalStatusUnknownEvent Warning NSX-T Logical Port Operational Status is 'Unknown' NSX-T Logical Port Operational Status is 'Unknown'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another. No
1.3.6.1.4.1.6876.100.1.0.80255 NSXTComputeManagerConnectionStatusNotUpEvent Warning NSX-T Compute Manager Connection Status in not up NSX-T Compute Manager Connection status is not up Yes
1.3.6.1.4.1.6876.100.1.0.80256 NSXTClusterBackUpDisabledEvent Warning NSX-T Manager backup is not scheduled. NSX-T Manager backup is not scheduled No
1.3.6.1.4.1.6876.100.1.0.80257 NSXTDFWFirewallDisabledEvent Critical NSX-T DFW Firewall is deactivated. Distributed Firewall is deactivated in the NSX-T Manager No
1.3.6.1.4.1.6876.100.1.0.80258 NSXTLogicalPortReceivedPacketDropEvent Warning NSX-T Logical Port Received Packets are getting dropped. Received packets are getting dropped on the NSX-T Logical Port and associated entities might get affected No
1.3.6.1.4.1.6876.100.1.0.80259 NSXTLogicalPortTransmittedPacketDropEvent Warning NSX-T Logical Port Transmitted Packets are getting dropped. Transmitted packets are getting dropped on the NSX-T Logical Port and associated entities might get affected No
1.3.6.1.4.1.6876.100.1.0.80260 NSXTLogicalSwitchReceivedPacketDropEvent Warning NSX-T Logical Switch Received Packets are getting dropped Received packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected No
1.3.6.1.4.1.6876.100.1.0.80261 NSXTLogicalSwitchTransmittedPacketDropEvent Warning NSX-T Logical Switch Transmitted Packets are getting dropped Transmitted packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected No
1.3.6.1.4.1.6876.100.1.0.80262 NSXTRxPacketDropOnMPNicEvent Warning Received packets are dropping on NSX-T Management Node's network interface Received packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. No
1.3.6.1.4.1.6876.100.1.0.80263 NSXTRxPacketDropOnEdgeTnNicEvent Critical Received packets are dropping on NSX-T Edge Node's network interface Received packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. No
1.3.6.1.4.1.6876.100.1.0.80264 NSXTRxPacketDropOnHostTnNicEvent Warning Received packets are dropping on NSX-T Host Node's network interface Received packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. No
1.3.6.1.4.1.6876.100.1.0.80265 NSXTTxPacketDropOnMPNicEvent Warning Transmitted packets are dropping on NSX-T Management Node's network interface Transmitted packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster. No
1.3.6.1.4.1.6876.100.1.0.80266 NSXTTxPacketDropOnEdgeTnNicEvent Critical Transmitted packets are dropping on NSX-T Edge Node's network interface Transmitted packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster. No
1.3.6.1.4.1.6876.100.1.0.80267 NSXTTxPacketDropOnHostTnNicEvent Warning Host Node's network interface Transmitted packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host. No
1.3.6.1.4.1.6876.100.1.0.80402 NSXTMPNodeServiceCmInventoryStatusEvent Warning CM Inventory Service has stopped running CM Inventory Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80403 NSXTMPNodeServiceControllerStatusEvent Warning Controller Service has stopped running. Controller Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80404 NSXTMPNodeServiceDataStoreStatusEvent Warning

DataStore Service has stopped running.

DataStore Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80405 NSXTMPNodeServiceHttpStatusEvent Warning HTTP Service has stopped running.

HTTP Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80406 NSXTMPNodeServiceInstallUpgradeEvent Warning Install Upgrade Service has stopped running. Install Upgrade Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80407 NSXTMPNodeServiceLiagentStatusEvent Warning

Liagent service has stopped running.

Liagent Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80408 NSXTMPNodeServiceManagerStatusEvent Warning Manager Service has stopped running. Manager Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80409 NSXTMPNodeServiceMgmtPlaneBusStatusEvent Warning Management Plane Service has stopped running. Management Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80410 NSXTMPNodeServiceMigrationCoordinatorStatusEvent Warning

Migration Co-ordinator Service has stopped running.

Migration Co-ordinator Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80411 NSXTMPNodeServiceNodeMgmtStatusEvent Warning Node Management Service has stopped running. Node Management Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80412 NSXTMPNodeServiceNodeStatsStatusEvent Warning Node Statistics Service has stopped running. Node Statistics Service status has turned to stopped. Yes
1.3.6.1.4.1.6876.100.1.0.80413 NSXTMPNodeServiceNSXMessageBusStatusEvent Warning Message Bus Service has stopped running.

Message Bus Client Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80414 NSXTMPNodeServiceNSXPlatformClientStatusEvent Warning Platform Client Service has stopped running.

Platform Client Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80415 NSXTMPNodeServiceNSXUpgradeAgentStatusEvent Warning Upgrade Agent Service has stopped running.

Upgrade Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80416 NSXTMPNodeServiceNTPStatusEvent Warning NTP Service has stopped running.

NTP Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80417 NSXTMPNodeServicePolicyStatusEvent Warning Policy Service has stopped running.

Policy Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80418 NSXTMPNodeServiceSearchStatusEvent Warning Search Service has stopped running.

Search Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80419 NSXTMPNodeServiceSNMPStatusEvent Warning

SNMP Service has stopped running.

SNMP Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80420 NSXTMPNodeServiceSSHStatusEvent Warning SSH Service has stopped running.

SSH Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80421 NSXTMPNodeServiceSyslogStatusEvent Warning Syslog Service has stopped running.

Syslog Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80422 NSXTMPNodeServiceTelemetryStatusEvent Warning

Telemetry Service has stopped running.

Telemetry Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80423 NSXTMPNodeServiceUIServiceStatusEvent Warning

UI Service has stopped running.

UI Service status has turned to stopped.

Yes
1.3.6.1.4.1.6876.100.1.0.80424 NSXTMPNodeServiceClusterManagerStatusEvent Critical Cluster Manager Service has stopped One of the Services of the NSX-T Management Node, namely Cluster Manager Service has stopped running. Yes

NSX-T System Events

Here is the list of NSX-T 2.2 to 2.5 events supported in VMware Aria Operations for Networks. The Object ID (OID) for all these NSX-T system events is 1.3.6.1.4.1.6876.100.1.0.80203.

Starting from 6.3 release, all NSX-T system events are optimized for quick notification and are delivered before 5 minutes.

Table 2. NSX-T System Events
Event Name Description
vmwNSXPlatformSysCpuUsage CPU Usage on both manager and edge appliances (NSX-T 2.2).
vmwNSXPlatformSysDiskUsage Disk Space Usage on both manager and edge appliance for /var/log partition (NSX-T 2.2).
vmwNSXPlatformSysMemUsage Memory Usage on both manager and edge appliance (NSX-T 2.2).
vmwNSXPlatformSysConfigDiskUsage Disk Usage for Manager and Edge Appliances for /config partition (NSX-T 2.4).
vmwNSXPlatformSysVarDumpDiskUsage Disk Usage for Manager and Edge Appliances for /var/dump partition (NSX-T 2.5).
vmwNSXPlatformSysRepositoryDiskUsage Disk Usage for Manager and Edge Appliances for /repository partition (NSX-T 2.5).
vmwNSXPlatformSysRootDiskUsage Disk usage for Manager and Edge appliances for root partition (NSX-T 2.5).
vmwNSXPlatformSysTmpDiskUsage Disk usage for Manager and Edge appliances for tmp partition (NSX-T 2.5).
vmwNSXPlatformSysImageDiskUsage Disk Usage for Manager and Edge appliances for /image partition (NSX-T 2.5).
vmwNSXDhcpPoolUsageOverloadedEvent DHCP pool overloaded/normal (NSX-T 2.5).
vmwNSXDhcpPoolLeaseAllocationFailedEvent DHCP pool lease allocation failed/succeeded (NSX-T 2.5).
vmwNSXPlatformPasswordExpiryStatus Password expiration for manager (NSX-T 2.4).
vmwNSXPlatformCertificateExpiryStatus Certificate expiration for manager (NSX-T 2.4).
vmwNSXRoutingBgpNeighborStatus BGP neighbor status (NSX-T 2.2).
vmwNSXVpnTunnelState VPN Tunnel up/down (NSX-T 2.2).
vmwNSXVpnL2TunnelStatus L2 VPN Session up/down (NSX-T 2.2).
vmwNSXVpnIkeSessionStatus IKE Session up/down (NSX-T 2.2).
vmwNSXDnsForwarderStatus DNS Forwarder Status (NSX-T 2.4).
vmwNSXClusterNodeStatus Cluster Node status (NSX-T 2.4).
vmwNSXFabricCryptoStatus Edge crypto mux driver failed/passed Known_Answer_Tests(KAT) (NSX-T 2.4).
Manager Disk Utilization is not OK
BGP Neighbor down Need an alert when the BGP neighbor is down.
BGP Neighbor Up Clear Alarm when a neighbor comes up.
Storage usage over X Alarm for Storage over X - Event is raised for all appliance VM (MP, CCP) or transport nodes (edge, host).
Memory usage over X Alarm for Memory over X - Event is raised for all appliance VM (MP, CCP) or transport nodes (edge, host).
CPU usage over X Alarm for CPU over X - Event is raised for all appliance VM (MP, CCP) or transport nodes (edge, host).

NSX-T System Alarms

In addition to NSX-T events, all NSX-T 3.0 alarms are displayed as NSX-T system events in VMware Aria Operations for Networks 5.2 and later. You can see the complete list alarms generated by NSX-T at: https://nsx-t_ip_address/nsx/#/app/home/alarms/alarm-definitions. Here, replace nsx-t_ip_address with the IP address of your NSX-T instance.

Note: Starting from 6.3 release, all NSX-T system alarms are optimized for quick notification and are delivered before 5 minutes.