Procedure
- Log in to the management interface of the Cloud Director Replication Management Appliance.
- In a Web browser, go to https://Appliance-IP-Address/ui/admin.
- Select Appliance login and enter the root user credentials.
- Click Login.
- In the left pane, under Configuration click Events and Notifications.
Note: To forward provider events to the syslog server and to email, first you must configure these delivery channels. Without configuration, the
Syslog and the
Cloud Director email check boxes remain dimmed.
- To configure the syslog server, under Settings next to Syslog click Configure.
- In the Syslog window, enter the syslog server address and the UDP port.
- To save the syslog configuration, click Apply.
- (Optional) To configure the email notifications in the VMware Cloud Director Provider Portal, under Settings next to Cloud Director Email click the Configure in Cloud Director link.
VMware Cloud Director Availability reads the following email settings from
VMware Cloud Director:
- The SMTP server configuration.
- The sender email address.
- The recipients of the email, either explicit email address or the email addresses of organization administrators.
- The default subject prefix.
- To configure the time before a given event is forwarded again, while the condition is still active, under Settings next to Monitoring events forwarding time, click Edit.
The default
Monitoring events forwarding time is 24 hours.
- In the Events configuration window, under Monitoring events forwarding time enter the forwarding time.
- To save the configuration for events notifications reposting, click Apply.
- Under Events next to System Management Events, click Edit.
- Next to System Management Channels, select Syslog, and or Cloud Director events, and or Cloud Director email as the notifications delivery channel.
- To save the selected delivery channels, in the System Management Events window, click Apply.
- Under Events next to System Monitoring Events, click Edit and to save the settings click Apply.
Option |
Description |
System Monitoring Channels |
Select Syslog, and or Cloud Director events, and or Cloud Director email as the notifications delivery channel. |
Connectivity poll interval |
Time interval between polls for connectivity issues. The default value is 30 seconds. |
Configuration poll interval |
Time interval between polls for configuration issues. The default value is 1 day. |
Certificate expiry threshold |
The time before a certificate expires to start forwarding events. The default value is 30 days. |
Policy compliance poll interval |
The time between polls for policy compliance issues. The default value is 60 minutes. |
- Under Events next to Replication Management Events, click Edit.
- Next to Replication Management Channels, select Syslog and or Cloud Director events as the notifications delivery channel.
- To save the selected delivery channels, in the Replication Management Events window, click Apply.
- Under Events, next to Replication Monitoring Events click Edit and to save the settings click Apply.
Option |
Description |
Replication Monitoring Channels |
Select Syslog, and or Cloud Director events, and or Cloud Director email as the notifications delivery channel. |
Poll interval |
Time interval between polls for replication issues. The default value is 5 minutes. |
RPO violation threshold time |
Only forward events for replications with RPO violation time above this threshold. Use 0 to forward events for any RPO violation. The default value is 30 minutes. |
RPO violation threshold time |
Only forward events for replications with RPO violations count above this threshold. Use 0 to forward events for any number of replications with an RPO violation. The default value is 0. |