What's New

The vCloud Director 9.7.0.5 for Service Providers Express Patch Release provides bug fixes, updates the vCloud Director appliance base OS and the vCloud Director open-source components. 

System Requirements and Installation

For more information about system requirements and installation instructions, see vCloud Director 9.7 for Service Providers Release Notes.

Documentation

To access the full set of product documentation, go to VMware vCloud Director for Service Providers Documentation.

Previous Releases of vCloud Director 9.7.x for Service Providers

vCloud Director 9.7.0.4 for Service Providers Release Notes

vCloud Director 9.7.0.3 for Service Providers Release Notes

vCloud Director 9.7.0.2 for Service Providers Release Notes

vCloud Director 9.7.0.1 for Service Providers Release Notes

vCloud Director 9.7 for Service Providers Release Notes

Resolved Issues

  • Powering on a newly deployed vApp fails with an error message

    In an organization VDC that is configured with multiple clusters, when you try to power on a newly deployed vApp, the operation fails with a moveVmIntoOvdcHubIfNecessary error message.

  • CPU and memory reservation settings are not applied on a newly deployed VM

    The issue occurs when you use vApp templates with configured CPU and memory reservation settings. When you deploy a new vApp from the template, the reservation settings are not applied on the new VMs.

  • Adding an edge gateway firewall rule fails

    In an edge gateway with enabled distributed logical routing, if you select a network with distributed routing interface as the source or destination for a new firewall rule, the operation fails with an error message.
    Invalid vnicGroupId vnic-index-X is specified or vnic-index-X is being deleted but consumed in firewall rule id 0., error code 12008

  • You cannot change the target VDC when creating a vApp from a catalog

    When you initiate the creation of a new vApp from a vApp template stored in a catalog, vCloud Director selects automatically the source VDC, and you cannot change to the VDC in which you want to create the new vApp.

  • Emails for expired vApps are sent to all members of an organization instead of sending them only to the organization administrator

    When a vApp storage lease expires, an email notification is sent not only to the organization administrator, but also to all members of the same vCloud Director organization, irrespective of their assigned user role.

  • Converting the interface of an organization VDC network from Internal to Subinterface fails

    In the vCloud Director Web Console, when you try to convert the interface of an organization VDC network from Internal to Subinterface, the operation fails with an error message.
    Logical switch Id 'id-of-logical-switch' of sub-interface index '10' and TRUNK vnic's backing distributed portgroup should be on the same switch., error code 10196

  • Updating an existing IPsec VPN site or configuring a new IPsec VPN site, resets the IPsec VPN tunnel

    On an edge gateway with a configured IPsec VPN connection between the sites, updating an existing or configuring a new IPsec VPN site resets the existing IPsec VPN tunnels. 

  • Updating the properties of an NSX edge gateway causes a redeployment of the same edge gateway

    If you configure an NSX edge gateway as Large, when you update its properties, the vApp placement engine redeploys the same NSX edge gateway.

  • Using the vCloud Director REST API to run a GET query might not return the full list with edge gateways

    For an organization VDC configured with 1000 or more edge gateways, an API GET /network/edges query does not return the full list of edge gateways in the organization VDC.

  • vCloud Director organization administrators receive a bounce email from nobody@vmware.com

    When vCloud Director sends alert email notifications to the default user account nobody@vmware.com, the organization administrators receive a bounce email from nobody@vmware.com.

  • In the vCloud Director Tenant Portal, updating the existing source NAT (SNAT) rule configuration removes the destination IP address

    On an edge gateway, updating the configuration of an existing SNAT rule removes the destination IP address.

  • You can create a snapshot of a vApp or VM located outside your current organization VDC by using the API

     If you have a local organization administrator credentials, by using the API you can create snapshots of vApps and VMs located in other organization VDCs.

  • Adding a new virtual machine to a vApp fails

    If your vApp external network is configured with multiple subnets, adding a new virtual machine to this vApp fails with an Existing subnets cannot be deleted error message.

  • Restarting the vCloud Director appliance resets the network interface static routing 

    After you restart the vCloud Director appliance, the network interface configurations for static routing are reset.

  • The Peripheral Component Interconnect (PCI) slot numbers in a newly created from a template virtual machine are in incorrect order

    In a new vApp, after you added a VM from a template, the PCI slot numbers in the resulting VM do not match the PCI slot numbers in the source VM template.

  • Renaming a virtual machine deletes the existing Single Root I/O Virtualization enabled NIC

    In a VM configured with a NIC that supports Single Root I/O Virtualization (SR-IOV), renaming the VM deletes the SR-IOV enabled NIC.

  • Updating the properties of a virtual machine deletes the configured reservation settings for CPU and memory

    In an organization VDC that has a reservation pool set, updating the properties of a VM resets the existing reservation settings for CPU and memory. 

  • You cannot select a predefined service when adding a new distributed firewall rule to an organization VDC 

    When you add a new distributed firewall rule to an organization VDC, the filter for selecting a predefined service of the new rule is case-sensitive and you cannot select the service.

  • When using the vCloud Director API, reverting a vApp with multiple VMs to a snapshot fails

    If you have multiple VMs in a vApp, when you try to revert the vApp to a snapshot by using an API, the operation fails with a HibernateException error message.

  • vCloud Director Tenant Portal takes longer than the vRealize Orchestrator Client to display a workflow as completed

    When the vRealize Orchestrator client runs the Deploy a new vApp workflow, if you add simultaneously multiple VMs to a VM group, the vCloud Director Tenant Portal takes longer than the vRealize Orchestrator Client to display the workflow as completed.

Known Issues

  • With AES-GCM as encryption algorithm for IPsec VPN, opening the properties of an edge gateway fails

    If during configuration of the IPsec VPN sites you selected AES-GCM as the encryption algorithm, viewing the properties of an edge gateway with enabled the IPsec VPN service fails with an error message.
    java.lang.NullPointerException

    Workaround: Use other encryption algorithm than the AES-GCM algorithm.

  • You cannot create a new standalone virtual machine that uses custom storage policy

    In the vCloud Director Tenant Portal, when you create a new standalone VM by using a template and you select the custom storage policy option, the deployment of the VM fails with an error message.
    HTTP 400 Bad Request

    Workaround: To assign a custom storage policy to a new VM:

    1. Create the standalone VM on the default storage policy.
    2. After the standalone VM is created, edit the VM properties and change from default storage policy to a custom storage policy.