Specify the networking information for the VI workload domain.

Before you begin

Verify that you have met the networking prerequisites as described in Create a Virtual Infrastructure Workload Domain.

Important:

If you enter custom network configurations for the vMotion, Virtual SAN, and VXLAN networks instead of using the default configurations, do not duplicate any of the VLAN ID, subnet (network ID), or gateway addresses that you already entered during creation of other workload domains. For example, if you previously created a VI workload domain and used value 50.0.0.0 for its vMotion network subnet field, do not re-use that value.

About this task

For the workload domain's management network, the creation workflow uses the management network that was configured during your installation's bring-up process. During deployment of the VI workload domain's infrastructure, the workflow also configures the networks used by the vMotion, Virtual SAN, and VXLAN capabilities in the workload domain. You can choose to use the default configurations or specify new ones in the Network step of the wizard. For each subnet, you can also specify excluded IP addresses to prevent the workflow from assigning those IP addresses to the workload domain's resources.

Important:

If you specify IP addresses for exclusion for a subnet in these wizard screens, they override any IP exclusions that were entered originally during your installation's bring-up process for that subnet. See About Excluding IP Address from SDDC Manager Use.

Table 1. VI Workload Domain Network Configurations

Network Configuration

Description

Management

By default, the workload domain's management network configuration uses the management network that was configured during the bring-up process.

vMotion

When you select to use the defaults, the workload domain's vMotion configuration uses the vMotion network that was configured during the bring-up process.

If you choose to use this default, but the software detects inadequate IP address space in the existing vMotion network, you must specify a new configuration at that step in the wizard.

Virtual SAN

When you select to use the defaults, the workload domain's Virtual SAN configuration uses a portion of the Virtual SAN network configuration that was configured during the bring-up process and allocates a VLAN ID from its pool.

If you choose to use this default, but the software detects inadequate IP address space in the existing Virtual SAN network, you must specify a new configuration at that step in the wizard.

VXLAN

When you select to use the defaults, the workload domain's VXLAN configuration uses the VXLAN network that was configured during the bring-up process.

If you choose to use this default, but the software detects inadequate IP address space in the existing VXLAN network, you must specify a new configuration at that step in the wizard.

Data Center connection

Used for access from outside this Cloud Foundation installation to the workloads that you run in the workload domain. At this wizard step, you can:

  • Select the network configuration that was configured during the bring-up process.

  • Select a network configuration that was configured in advance using the Data Center Connections settings screen.

  • Enter a new configuration. A VLAN ID is required.

Important:

Do not select a data center connection that is already associated with a VDI workload domain or unexpected results might occur.

Procedure

  1. Choose whether to use already-configured vMotion, Virtual SAN, and VXLAN networks for this VI workload domain.
    • Select the USE ALL DEFAULT NETWORKS check box. After selecting the USE ALL DEFAULT NETWORKS check box, click Next to proceed to the next wizard step for specifying the Data Center connection.

      Note:

      When you select the USE ALL DEFAULT NETWORKS check box, you need to configure the Data Center connection only.

      Continue with 8.

    • Leave the USE ALL DEFAULT NETWORKS check box unselected and click Next to proceed.

  2. (Optional) : For the management network configuration, if you want to prevent the workflow from assigning some of the subnet's IP addresses to the workload domain's resources, type those addresses or ranges.

    Other than the IP address exclusion fields, the other fields on this screen are read-only. The displayed management network settings are the ones that were specified during your installation's bring-up process. Because the workload domains use the same management network, you cannot change these settings when configuring a workload domain.

    Caution:

    If you specify IP addresses for exclusion in this screen, they override any IP exclusions that were entered originally during the bring-up process. See About Excluding IP Address from SDDC Manager Use.

  3. Click Next to proceed to the vMotion network configuration.
  4. For the vMotion network configuration, choose one of these options.
    • To use the same vMotion network configuration that was specified during your installation's bring-up process, make sure the USE DEFAULTS check box is checked and proceed to the Virtual SAN network configuration.

    • To specify a custom vMotion network for this workload domain, clear the USE DEFAULTS check box, type the network settings, and then proceed to the Virtual SAN network configuration. A minimum subnet mask of /22 is recommended.

      Note:

      If you choose to use the defaults, but the software detects inadequate IP address space in the existing network, you must specify a new configuration.

  5. Click Next to proceed to the Virtual SAN network configuration.
  6. For the Virtual SAN network configuration, choose one of these options.
    • To use the same Virtual SAN network configuration that was specified during your installation's bring-up process, check the USE DEFAULTS check box and proceed to the VXLAN network configuration.

    • To specify a custom Virtual SAN network for this workload domain, clear the USE DEFAULTS check box if it is selected, type the Virtual SAN network settings, and then proceed to the VXLAN network configuration. A minimum subnet mask of /22 is recommended.

      Note:

      If you choose to use the defaults, but the software detects inadequate IP address space in the existing network, you must specify a new configuration.

    Caution:

    If you specify IP addresses for exclusion in this screen, they override any IP exclusions that were entered originally during your installation's bring-up process. See About Excluding IP Address from SDDC Manager Use.

  7. For the VXLAN network configuration, choose one of these options.
    • To use the same VXLAN network configuration that was specified during your installation's bring-up process, check the USE DEFAULTS check box and proceed to the Data Center connection configuration.

    • To specify a custom VXLAN network for this workload domain, type the VXLAN network settings and then proceed to the Data Center network configuration. A minimum subnet mask of /22 is recommended.

  8. (Optional) : For the Data Center connection, choose one of these options.
    • Select one of the configurations that is already in place. During ongoing operations, Data Center configurations are established using the Settings > Network Settings > Data Centerscreen.

    • Use the drop-down Custom Configuration choice to create a new configuration to be used for this workload domain. A VLAN ID is required.

    Explicitly specifying a data center connection at this step is optional. If you do not specify a data center connection, the workflow uses the one associated with the management domain by default.

    Important:

    Do not select a data center connection that is already associated with a VDI workload domain or unexpected results might occur.

  9. Proceed to the next step by clicking Next.