VMware Cloud Foundation 3.7.1 on Dell EMC VxRail Release Notes
VMware Cloud Foundation 3.7.1 on Dell EMC VxRail | 02 MAY 2019 | Build 13532358
Check regularly for additions and updates to these release notes. |
VMware Cloud Foundation (VCF) on Dell EMC VxRail is a solution offering that provides best-in-class serviceability and lifecycle management capabilities for customers looking to automate the deployment and management of the full VMware Software Defined Datacenter (SDDC) stack on Dell EMC VxRail.
The release notes cover the following topics:
This release has the following features:
- Stretch Cluster Expansion - Enables the automation of the expansion of stretch clusters.
- Manual Download and Upload of Bundles - Provides the support for the manual upload of the bundles to schedule the upgrades for their domains.
- Support for Dell EMC VxRail 4.7.111 - Provides the suppport for the integration of VMware Cloud Foundation 3.7.1 with Dell EMC VxRail 4.7.111.
The following documentation is available:
VMware Cloud Foundation on Dell EMC VxRail Admin Guide
VMware Cloud Foundation 3.7.1 Release Notes
Support Matrix of VMware Cloud Foundation on Dell EMC VxRail
Validation is not happening in sequential order in the Cloud Foundation builder VM
This issue is observed during the bring-up configuration file validation process where the validation tasks are not being executed in sequential manner,but being executed in some random order.
-
The vSAN Gateway is not being set on the static routes in a stretched cluster
In the vSAN stretch cluster workflow of VMware Cloud Foundation on Dell EMC VxRail, the static routes are configured for the ESXi hosts in Region A (AZ1 or AZ2) to reach the witness host/appliance in Region B. The issue is that, the management gateway is used in configuring the static routes. This results in unhealthy state of vSAN.
The new hosts are not associated automatically with vRealize Log Insight in the add-host workflow
If vRealize Log Insight has been enabled for the domains and the add host workflow is performed, then the new host does not get associated with the vRealize Log Insight instance for that domain.
Unable to cancel the bring-up configuration file validation tasks for VCF on VxRail
This issue is observed during the bring-up configuration file validation process when there is an error and the user tries to cancel the validation tasks. The validation tasks continue to run even after triggering the cancel operation.
The known issues and limitations for are as follows:
Upgrade bundles cannot be applied even after all of them have been downloaded
Symptoms of this issue:
- All upgrade bundles have been downloaded from the online depot but show up with the status of
Future on the LCM Upgrade GUI.
- Trying to upload the offline bundles produces the error
Invalid Software Compatibility Metadata Set in /var/log/vmware/vcf/lcm/lcm.log
Workaround: See KB 74727.
The VxRail upgrade bundles have to be downloaded again
In an environment running VCF 3.7.0 on VxRail 4.7.110, after downloading the upgrade bundles for VCF 3.7.1 and VxRail 4.7.111, if you apply the VCF 3.7.1 patch, then you will be forced to download the VxRail 4.7.111 bundle again.
Workaround:
- Download and apply the VCF 3.7.1 patch.
- Download and apply the VxRail 4.7.111 patch.
Workload domain vcenter upgrade is failing
The vCenter upgrade is failing for the workload domain due to the missing vc rsa-key in SDDC Manager inside the known host file("~/.ssh/known_hosts ).
Workaround:
- SSH of SDDC Manager using
vcf user .
- Execute
ssh -o HostKeyAlgorithms=ssh-rsa root@
<VC_IP>.
-
NSX-T is not supported for the VMware Cloud Foundation 3.7 deployments on VxRail
Currently, only NSX-V 6.4.4 is supported for VMware Cloud Foundation 3.7 deployed on Dell EMC VxRail.
Workaround: None
The add secondary cluster operation on the management domain fails.
After deploying the VMware Cloud Foundation on Dell EMC VxRail management domain, when you try to add the secondary cluster to it, the task fails.
Workaround: None
|