VMware Cloud Foundation uses VMware vSAN as the principal storage type for the management domain and recommended for use as principal storage in VI workload domains. You must determine the size of the compute and storage resources for the vSAN storage, and the configuration of the network carrying vSAN traffic. For multiple availability zones, you extend the resource size and determine the configuration of the vSAN witness host.
Logical Design for vSAN for VMware Cloud Foundation
vSAN is a cost-efficient storage technology that provides a simple storage management user experience, and permits a fully automated initial deployment of VMware Cloud Foundation. It also provides support for future storage expansion and implementation of vSAN stretched clusters in a workload domain.
Workload Domain Type |
VMware Cloud Foundation Instances with a Single Availability Zone |
VMware Cloud FoundationInstances with Multiple Availability Zones |
---|---|---|
Management domain (default cluster) |
Four nodes minimum |
|
Management domain (additional clusters) |
|
|
VI workload domain (all clusters) |
|
|
Hardware Configuration for vSAN for VMware Cloud Foundation
Determine the type of the capacity and caching devices, and the storage controllers for performance and stability according to the requirements of the management components of VMware Cloud Foundation.
vSAN Physical Requirements and Dependencies
vSAN has the following requirements and options:
vSAN Original Storage Architecture (OSA) as hybrid storage or all-flash storage.
A vSAN hybrid storage configuration requires both magnetic devices and flash caching devices. The cache tier must be at least 10% of the size of the capacity tier.
An all-flash vSAN configuration requires flash devices for both the caching and capacity tiers.
VMware vSAN ReadyNodes or hardware from the VMware Compatibility Guide to build your own.
-
vSAN Express Storage Architecture (ESA)
-
All storage devices claimed by vSAN contribute to capacity and performance. Each host's storage devices claimed by vSAN form a storage pool. The storage pool represents the amount of caching and capacity provided by the host to the vSAN datastore.
-
ESXi hosts must be on the vSAN ESA Ready Node HCL with a minimum of 512 GB RAM per host.
Note: vSAN Express Storage Architecture is not supported with VMware Cloud Foundation. -
For best practices, capacity considerations, and general recommendations about designing and sizing a vSAN cluster, see the VMware vSAN Design and Sizing Guide.
Network Design for vSAN for VMware Cloud Foundation
In the network design for vSAN in VMware Cloud Foundation, you determine the network configuration for vSAN traffic.
Consider the overall traffic bandwidth and decide how to isolate storage traffic.
Consider how much vSAN data traffic is running between ESXi hosts.
The amount of storage traffic depends on the number of VMs that are running in the cluster, and on how write-intensive the I/O process is for the applications running in the VMs.
For information on the physical network setup for vSAN traffic, and other system traffic, see Physical Network Infrastructure Design for VMware Cloud Foundation.
For information on the virtual network setup for vSAN traffic, and other system traffic, see Logical vSphere Networking Design for VMware Cloud Foundation.
The vSAN network design includes these components.
Design Component |
Description |
---|---|
Physical NIC speed |
For best and most predictable performance (IOPS) for the environment, this design uses a minimum of a 10-GbE connection, with 25-GbE recommended, for use with vSAN all-flash configurations. |
VMkernel network adapters for vSAN |
The vSAN VMkernel network adapter on each ESXi host is created when you enable vSAN on the cluster. Connect the vSAN VMkernel network adapters on all ESXi hosts in a cluster to a dedicated distributed port group including also ESXi hosts that are not contributing storage resources to the cluster. |
VLAN |
All storage traffic should be isolated on its own VLAN. When a design uses multiple vSAN clusters, each cluster should use a dedicated VLAN or segment for its traffic. This approach increases security, prevents interference between clusters, and helps with troubleshooting cluster configuration. |
Jumbo frames |
vSAN traffic can be handled by using jumbo frames. Use jumbo frames for vSAN traffic only if the physical environment is already configured to support them, they are part of the existing design, or if the underlying configuration does not create a significant amount of added complexity to the design. |
vSAN Witness Design for VMware Cloud Foundation
The vSAN witness appliance is a specialized ESXi installation that provides quorum and tiebreaker services for stretched clusters in VMware Cloud Foundation.
vSAN Witness Deployment Specification
When using vSAN in a stretched cluster configuration, you must deploy a witness ESXi host. This appliance must be deployed in a third location that is not local to the ESXi hosts on either side of the stretched cluster.
Appliance Size |
Maximum Number of Supported Virtual Machines |
Maximum Number of Supported Witness Components |
---|---|---|
Tiny |
10 |
750 |
Medium |
500 |
21, 000 |
Large |
500 |
64, 000 |
vSAN Witness Network Design
When using two availability zones, connect the vSAN witness appliance to the workload domain vCenter Server so that you can perform the initial setup of the stretched cluster and have workloads failover between the zones.
VMware Cloud Foundation uses vSAN witness traffic separation where you can use a VMkernel adapter for vSAN witness traffic that is different from the adapter for vSAN data traffic. In this design, you configure vSAN witness traffic in the following way:
On each ESXi host in both availability zones, place the vSAN witness traffic on the management VMkernel adapter.
On the vSAN witness appliance, use the same VMkernel adapter for both management and witness traffic.
For information about vSAN witness traffic separation, see vSAN Stretched Cluster Guide on VMware Cloud Platform Tech Zone.
- Management network
-
Routed to the management networks in both availability zones. Connect the first VMkernel adapter of the vSAN witness appliance to this network. The second VMkernel adapter on the vSAN witness appliance is not used.
Place the following traffic on this network:
Management traffic
vSAN witness traffic
vSAN Design Requirements and Recommendations for VMware Cloud Foundation
Consider the requirements for using vSAN storage for standard and stretched clusters in VMware Cloud Foundation, such as required capacity, number of hosts, number of disk groups, storage policy, and the similar best practices for having vSAN operate in an optimal way.
For related vSphere cluster requirements and recommendations, see vSphere Cluster Design Requirements and Recommendations for VMware Cloud Foundation.
vSAN Design Requirements
You must meet the following design requirements for standard and stretched clusters in your vSAN design for VMware Cloud Foundation.
Requirement ID |
Design Requirement |
Justification |
Implication |
---|---|---|---|
VCF-VSAN-REQD-CFG-001 |
Provide sufficient raw capacity to meet the initial needs of the workload domain cluster. |
Ensures that sufficient resources are present to create the workload domain cluster. |
None. |
VCF-VSAN-REQD-CFG-002 |
Provide at least the required minimum number of hosts according to the cluster type.
|
Satisfies the requirements for storage availability. |
None. |
Requirement ID |
Design Requirement |
Justification |
Implication |
---|---|---|---|
VCF-VSAN-REQD-CFG-003 |
Add the following setting to the default vSAN storage policy: Site disaster tolerance = Site mirroring - stretched cluster |
Provides the necessary protection for virtual machines in each availability zone, with the ability to recover from an availability zone outage. |
You might need additional policies if third-party virtual machines are to be hosted in these clusters because their performance or availability requirements might differ from what the default VMware vSAN policy supports. |
VCF-VSAN-REQD-CFG-004 |
Configure two fault domains, one for each availability zone. Assign each host to their respective availability zone fault domain. |
Fault domains are mapped to availability zones to provide logical host separation and ensure a copy of vSAN data is always available even when an availability zone goes offline. |
You must provide additional raw storage when the site mirroring - stretched cluster option is selected and fault domains are enabled. |
VCF-VSAN-WTN-REQD-CFG-001 |
Deploy a vSAN witness appliance in a location that is not local to the ESXi hosts in any of the availability zones. |
Ensures availability of vSAN witness components in the event of a failure of one of the availability zones. |
You must provide a third physically-separate location that runs a vSphere environment. You might use a VMware Cloud Foundation instance in a separate physical location. |
VCF-VSAN-WTN-REQD-CFG-002 |
Deploy a witness appliance of a size that corresponds to the required capacity of the cluster.
|
Ensures the witness appliance is sized to support the projected workload storage consumption. |
The vSphere environment at the witness location must satisfy the resource requirements of the witness appliance. |
VCF-VSAN-WTN-REQD-CFG-003 |
Connect the first VMkernel adapter of the vSAN witness appliance to the management network in the witness site. |
Enables connecting the witness appliance to the workload domain vCenter Server. |
The management networks in both availability zones must be routed to the management network in the witness site. |
VCF-VSAN-WTN-REQD-CFG-004 |
Allocate a statically assigned IP address and host name to the management adapter of the vSAN witness appliance. |
Simplifies maintenance and tracking, and implements a DNS configuration. |
Requires precise IP address management. |
VCF-VSAN-WTN-REQD-CFG-005 |
Configure forward and reverse DNS records for the vSAN witness appliance for the VMware Cloud Foundation instance. |
Enables connecting the vSAN witness appliance to the workload domain vCenter Server by FQDN instead of IP address. |
You must provide DNS records for the vSAN witness appliance. |
VCF-VSAN-WTN-REQD-CFG-006 |
Configure time synchronization by using an internal NTP time for the vSAN witness appliance. |
Prevents any failures in the stretched cluster configuration that are caused by time mismatch between the vSAN witness appliance and the ESXi hosts in both availability zones and workload domain vCenter Server. |
|
VCF-VSAN-WTN-REQD-CFG-007 |
Configure an individual vSAN storage policy for each stretched cluster. |
The vSAN storage policy of a stretched cluster cannot be shared with other clusters. |
You must configure additional vSAN storage policies. |
vSAN Design Recommendations
In your vSAN design for VMware Cloud Foundation, you can apply certain best practices for standard and stretched clusters .
Recommendation ID |
Design Recommendation |
Justification |
Implication |
---|---|---|---|
VCF-VSAN-RCMD-CFG-001 |
Ensure that the storage I/O controller that is running the vSAN disk groups is capable and has a minimum queue depth of 256 set. |
Storage controllers with lower queue depths can cause performance and stability problems when running vSAN. vSAN ReadyNode servers are configured with the right queue depths for vSAN. |
Limits the number of compatible I/O controllers that can be used for storage. |
VCF-VSAN-RCMD-CFG-002 |
Do not use the storage I/O controllers that are running vSAN disk groups for another purpose. |
Running non-vSAN disks, for example, VMFS, on a storage I/O controller that is running a vSAN disk group can impact vSAN performance. |
If non-vSAN disks are required in ESXi hosts, you must have an additional storage I/O controller in the host. |
VCF-VSAN-RCMD-CFG-003 |
Configure vSAN in all-flash configuration in the default workload domain cluster. |
Meets the performance needs of the default workload domain cluster. |
All vSAN disks must be flash disks, which might cost more than magnetic disks. |
VCF-VSAN-RCMD-CFG-004 |
Provide sufficient raw capacity to meet the planned needs of the workload domain cluster. |
Ensures that sufficient resources are present in the workload domain cluster, preventing the need to expand the vSAN datastore in the future. |
None. |
VCF-VSAN-RCMD-CFG-005 |
On the vSAN datastore, ensure that at least 30% of free space is always available. |
This free space, called slack space, is set aside for host maintenance mode data evacuation, component rebuilds, rebalancing operations, and VM snapshots. |
Increases the amount of available storage needed. |
VCF-VSAN-RCMD-CFG-006 |
Configure vSAN with a minimum of two disk groups per ESXi host. |
Reduces the size of the fault domain and spreads the I/O load over more disks for better performance. |
Using multiple disk groups requires more disks in each ESXi host. |
VCF-VSAN-RCMD-CFG-007 |
For the cache tier in each disk group, use a flash-based drive that is at least 600 GB large. |
Provides enough cache for both hybrid or all-flash vSAN configurations to buffer I/O and ensure disk group performance. Additional space in the cache tier does not increase performance. |
Using larger flash disks can increase the initial host cost. |
VCF-VSAN-RCMD-CFG-008 |
Use the default VMware vSAN storage policy. |
|
You might need additional policies for third-party virtual machines hosted in these clusters because their performance or availability requirements might differ from what the default VMware vSAN policy supports. |
VCF-VSAN-RCMD-CFG-009 |
Leave the default virtual machine swap file as a sparse object on vSAN. |
Sparse virtual swap files consume capacity on vSAN only as they are accessed. As a result, you can reduce the consumption on the vSAN datastore if virtual machines do not experience memory over-commitment which would require the use of the virtual swap file. |
None. |
VCF-VSAN-RCMD-CFG-010 |
Use the existing vSphere Distributed Switch instance in the workload domain cluster. |
Provides guaranteed performance for vSAN traffic in a connection-free network by using existing networking components. |
All traffic paths are shared over common uplinks. |
VCF-VSAN-RCMD-CFG-011 |
Configure jumbo frames on the VLAN for vSAN traffic. |
|
Every device in the network must support jumbo frames. |
Recommendation ID |
Design Recommendation |
Justification |
Implication |
---|---|---|---|
VCF-VSAN-WTN-RCMD-CFG-001 |
Configure the vSAN witness appliance to use the first VMkernel adapter, that is the management interface, for vSAN witness traffic. |
Removes the requirement to have static routes on the witness appliance as witness traffic is routed over the management network. |
The management networks in both availability zones must be routed to the management network in the witness site. |
VCF-VSAN-WTN-RCMD-CFG-002 |
Place witness traffic on the management VMkernel adapter of all the ESXi hosts in the workload domain. |
Separates the witness traffic from the vSAN data traffic. Witness traffic separation provides the following benefits:
|
The management networks in both availability zones must be routed to the management network in the witness site. |