You set up health check monitoring for VMware Aria Automation to monitor the server pool that you later create. Servers that fail to respond to the health checks within a specified time period are excluded from future connection handling.
Procedure
Log in to the NSX Global Manager for the management domain at https://<active_nsx_gm_fqdn>/login.jsp?local=true as admin.
From the drop-down menu at the top, select the recovery site NSX location according to your value in the VMware Cloud Foundation Planning and Preparation Workbook.
- On the main navigation bar, click Networking.
In the left pane, navigate to
.Click the Monitors tab.
From the Select monitor type drop-down menu, select Active.
From the Add active monitor drop-down menu, select HTTP and configure the following settings and configure the remaining settings according to your VMware Cloud Foundation Planning and Preparation Workbook.
Setting
Value
Protocol
HTTP
Monitoring port
8008
Monitoring interval
3
Timeout Period (s)
10
Fall count
3
Rise count
3
Configure HTTP request and response settings.
In the HTTP request section, click Configure.
In the HTTP request and response configuration dialog box, click the HTTP request configuration tab, and configure the settings.
Setting
Value
HTTP method
Get
HTTP request URL
/health
HTTP request version
1.1
Click the HTTP response configuration tab, configure the settings, and click Apply.
Setting
Value
HTTP response code
200
On the Monitors page, click Save.