You must configure a JSON formatted bring-up specification file for the automated installation and configuration of the SDDC instance. VMware will retrieve this information through a API call.
The JSON file must contain the all the configuration settings required for bring-up. An example is provided below:
SDDC Input Specification File (bringup.json)
Collapse source { "dataCenter": { "name": "MGMT_DC", "managementFolder": "MGMT_VMs", "clusters": { "management": { "name": "MGMT_CLU", "vsanClusterSpec": { "deduplication": true, "compression": true }, "hosts": [ { "username": "root", "password": "Skoda1!", "type": "PRIMARY", "vmknicSpecs": { "esxiMgmt": { "ipSpec": { "ip": "192.168.101.101", "subnet": "255.255.255.0", "fqdn": "esxmb1.cloud.vmw", "gw": "192.168.101.1" }, "type": "ESXi_MGMT", "name": "vmk0", "vlanId": 0 }, "vsan": { "ipSpec": { "ip": "192.168.102.101", "subnet": "255.255.255.0", "gw": "192.168.102.1" }, "type": "VSAN", "name": "vmk1", "vlanId": 0 }, "vmotion": { "ipSpec": { "ip": "192.168.103.101", "subnet": "255.255.255.0", "gw": "192.168.103.1" }, "type": "VMOTION_PG", "name": "vmk2", "vlanId": 0 }, "nfs": { "ipSpec": { "ip": "192.168.104.101", "subnet": "255.255.255.0", "gw": "192.168.104.1" }, "type": "NFS", "name": "vmk3", "vlanId": 0 } }, "pnicSpec": { "uplink1": { "name": "vmnic0" }, "uplink2": { "name": "vmnic1" } }, "vsanDiskSpec": { "autoDiskGroups": true, "diskGroups": [ ] } }, { "username": "root", "password": "Skoda1!", "type": "SECONDARY", "vmknicSpecs": { "esxiMgmt": { "ipSpec": { "ip": "192.168.101.102", "subnet": "255.255.255.0", "fqdn": "esxmb2.cloud.vmw", "gw": "192.168.101.1" }, "type": "ESXi_MGMT", "name": "vmk0", "vlanId": 0 }, "vsan": { "ipSpec": { "ip": "192.168.102.102", "subnet": "255.255.255.0", "gw": "192.168.102.1" }, "type": "VSAN", "name": "vmk1", "vlanId": 0 }, "vmotion": { "ipSpec": { "ip": "192.168.103.102", "subnet": "255.255.255.0", "gw": "192.168.103.1" }, "type": "VMOTION_PG", "name": "vmk2", "vlanId": 0 }, "nfs": { "ipSpec": { "ip": "192.168.104.102", "subnet": "255.255.255.0", "gw": "192.168.104.1" }, "type": "NFS", "name": "vmk3", "vlanId": 0 } }, "pnicSpec": { "uplink1": { "name": "vmnic0" }, "uplink2": { "name": "vmnic1" } }, "vsanDiskSpec": { "autoDiskGroups": true, "diskGroups": [ ] } }, { "username": "root", "password": "Skoda1!", "type": "SECONDARY", "vmknicSpecs": { "esxiMgmt": { "ipSpec": { "ip": "192.168.101.103", "subnet": "255.255.255.0", "fqdn": "esxmb3.cloud.vmw", "gw": "192.168.101.1" }, "type": "ESXi_MGMT", "name": "vmk0", "vlanId": 0 }, "vsan": { "ipSpec": { "ip": "192.168.102.103", "subnet": "255.255.255.0", "gw": "192.168.102.1" }, "type": "VSAN", "name": "vmk1", "vlanId": 0 }, "vmotion": { "ipSpec": { "ip": "192.168.103.103", "subnet": "255.255.255.0", "gw": "192.168.103.1" }, "type": "VMOTION_PG", "name": "vmk2", "vlanId": 0 }, "nfs": { "ipSpec": { "ip": "192.168.104.103", "subnet": "255.255.255.0", "gw": "192.168.104.1" }, "type": "NFS", "name": "vmk3", "vlanId": 0 } }, "pnicSpec": { "uplink1": { "name": "vmnic0" }, "uplink2": { "name": "vmnic1" } }, "vsanDiskSpec": { "autoDiskGroups": true, "diskGroups": [ ] } }, { "username": "root", "password": "Skoda1!", "type": "SECONDARY", "vmknicSpecs": { "esxiMgmt": { "ipSpec": { "ip": "192.168.101.104", "subnet": "255.255.255.0", "fqdn": "esxmb4.cloud.vmw", "gw": "192.168.101.1" }, "type": "ESXi_MGMT", "name": "vmk0", "vlanId": 0 }, "vsan": { "ipSpec": { "ip": "192.168.102.104", "subnet": "255.255.255.0", "gw": "192.168.102.1" }, "type": "VSAN", "name": "vmk1", "vlanId": 0 }, "vmotion": { "ipSpec": { "ip": "192.168.103.104", "subnet": "255.255.255.0", "gw": "192.168.103.1" }, "type": "VMOTION_PG", "name": "vmk2", "vlanId": 0 }, "nfs": { "ipSpec": { "ip": "192.168.104.104", "subnet": "255.255.255.0", "gw": "192.168.104.1" }, "type": "NFS", "name": "vmk3", "vlanId": 0 } }, "pnicSpec": { "uplink1": { "name": "vmnic0" }, "uplink2": { "name": "vmnic1" } }, "vsanDiskSpec": { "autoDiskGroups": true, "diskGroups": [ ] } } ] }, "secondaryClusters": [ ] } }, "vcSpec": { "credentialSpec": { "ssoPassword": "VMware123!", "ssoDomain": "vsphere.local", "rootVcenterPassword": "VMware123!" }, "managementNetwork": { "ip": "192.168.105.50", "fqdn": "vc.cloud.vmw", "prefix": "24", "gateway": "192.168.105.1" }, "esx1Datastore": "vsanDatastore", "licenseSpec": { "vcLicense": "", "hostLicense": "" }, "dep_network": "VM Network", "thin_disk_mode": "true", "deployment_option": "small" }, "dnsSpec": { "dns_1": [ "192.168.101.5" ], "domains": [ "cloud.vmw", "vmware.com" ] }, "ntpSpec": { "ntp_server": [ "time.vmware.com" ] }, "dvsSpec": { "dvsName": "MGMT_DVS" }, "resourcePools": { "managementResourcePool": "MGMT-ResourcePool", "workloadResourcePool": "Compute-ResourcePool" }, "nsxSpec": { "nsxManager1": { "credentialSpec":{ "rootPassword" : "NSRRocks123!", "cliPassword" : "NSRRocks123!", "auditPassword" : "NSRRocks123!" }, "managementNetwork":{ "ip": "192.168.105.51", "subnet": "255.255.255.0", "fqdn": "192.168.105.51", "gateway": "192.168.105.1" } }, "nsxManager2": { "credentialSpec":{ "rootPassword" : "NSRRocks123!", "cliPassword" : "NSRRocks123!", "auditPassword" : "NSRRocks123!" }, "managementNetwork":{ "ip": "192.168.105.52", "subnet": "255.255.255.0", "fqdn": "192.168.105.51", "gateway": "192.168.105.1" } }, "nsxManager3": { "credentialSpec":{ "rootPassword" : "NSRRocks123!", "cliPassword" : "NSRRocks123!", "auditPassword" : "NSRRocks123!" }, "managementNetwork":{ "ip": "192.168.105.53", "subnet": "255.255.255.0", "fqdn": "192.168.105.53", "gateway": "192.168.105.1" } }, "virtualIP": "192.168.105.55", "nsxEdgeSpec": { "edgeCluster": "NSX_EDGE_CLUSTER", "edgeNode1": { "credentialSpec": { "rootPassword": "NSRRocks123!", "cliPassword": "NSRRocks123!" }, "managementNetwork": { "ip": "192.168.105.61", "fqdn": "edge1.cloud.vmw", "prefix": "24", "gateway": "192.168.105.1", "subnet": "255.255.255.0" }, "datastore": "vsanDatastore", "deploymentNetwork": { "network0": "VM_MGMT", "network1": "EDGE_OVERLAY", "network2": "EDGE_UPLINK1", "network3": "EDGE_UPLINK2" }, "thinDiskMode": "true", "deploymentOption": "small", "nodeSwitch": { "nvds1": { "switchName": "NVDS-1", "uplinkProfile": "nsx-edge-overlay-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth0" } }, "nvds2": { "switchName": "NVDS-2", "uplinkProfile": "nsx-edge-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth1" } }, "nvds3": { "switchName": "NVDS-3", "uplinkProfile": "nsx-edge-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth2" } } } }, "edgeNode2": { "credentialSpec": { "rootPassword": "NSRRocks123!", "cliPassword": "NSRRocks123!" }, "managementNetwork": { "ip": "192.168.105.62", "fqdn": "edge2.cloud.vmw", "prefix": "24", "gateway": "192.168.105.1", "subnet": "255.255.255.0" }, "datastore": "vsanDatastore", "deploymentNetwork": { "network0": "VM_MGMT", "network1": "EDGE_OVERLAY", "network2": "EDGE_UPLINK1", "network3": "EDGE_UPLINK2" }, "thinDiskMode": "false", "deploymentOption": "small", "nodeSwitch": { "nvds1": { "switchName": "NVDS-1", "uplinkProfile": "nsx-edge-overlay-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth0" } }, "nvds2": { "switchName": "NVDS-2", "uplinkProfile": "nsx-edge-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth1" } }, "nvds3": { "switchName": "NVDS-3", "uplinkProfile": "nsx-edge-uplink-profile", "ipPool": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "virtualNic": { "uplinkName": "uplink-1", "deviceName": "fp-eth2" } } } } }, "uplinkProfileSpec": { "nsxEdgeOverlayUplinkProfile": { "displayName": "nsx-edge-overlay-uplink-profile", "description": "Used to define how the Edge Node VMs connect to the network to provide participate in the Overlay network.", "mtu": "9000", "transportVlan": "0", "teaming": { "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-1", "uplinkType": "PNIC" } ], "policy": "FAILOVER_ORDER" } }, "nsxEdgeUplinkProfile": { "displayName": "nsx-edge-uplink-profile", "description": "Used to define how the Edge Node VMs connect to the physical network.", "mtu": "1500", "transportVlan": "0", "teaming": { "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-1", "uplinkType": "PNIC" } ], "policy": "FAILOVER_ORDER" } }, "hostUplinkProfile": { "displayName": "host-uplink-profile", "mtu": "9000", "teaming": { "policy": "LOADBALANCE_SRCID", "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-1", "uplinkType": "PNIC", "deviceName": "vmnic2" }, { "uplinkName": "uplink-2", "uplinkType": "PNIC", "deviceName": "vmnic3" } ] }, "transportVlan": "1200", "namedTeamings": [ { "name": "Edge_Transport", "policy": "FAILOVER_ORDER", "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-1", "uplinkType": "PNIC" } ] }, { "name": "Uplink1_Only", "policy": "FAILOVER_ORDER", "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-1", "uplinkType": "PNIC" } ] }, { "name": "Uplink2_Only", "policy": "FAILOVER_ORDER", "standbyList": [ ], "activeList": [ { "uplinkName": "uplink-2", "uplinkType": "PNIC" } ] } ] } }, "ipPoolSpec": { "sddcIpPool": { "displayName": "SDDC_ESX_TEP_IP_POOL_GENEVE2", "start": "192.168.106.10", "end": "192.168.106.30", "cidr": "192.168.106.0/24", "tepGatewayIp": "192.168.106.1" }, "sddcEdgeIpPool": { "displayName": "SDDC_EDGE_TEP_IP_POOL_GENEVE2", "start": "192.168.107.10", "end": "192.168.107.20", "cidr": "192.168.107.0/24", "tepGatewayIp": "192.168.107.1" } }, "nsxTransportZones": { "sddcNvdsName": "NVDS-1", "edgeUplink1TransportZone": { "displayName": "SDDC_EDGE_UPLINK1_TZONE", "hostSwitchName": "NVDS-2", "description": "Used for connecting one of the Edge Node VMs interfaces to the physical network", "transportType": "VLAN" }, "edgeUplink2TransportZone": { "displayName": "SDDC_EDGE_UPLINK2_TZONE", "hostSwitchName": "NVDS-3", "description": "Used for connecting one of the Edge Node VMs interfaces to the physical network", "transportType": "VLAN" }, "vlanTransportZone": { "displayName": "SDDC_VLAN_TZONE", "hostSwitchName": "NVDS-1", "description": "SDDC_VLAN_TZONE", "transportType": "VLAN", "uplinkTeamingPolicyNames": [ "Edge_Transport", "Uplink1_Only", "Uplink2_Only" ] }, "overlayTransportZone": { "displayName": "SDDC_OVERLAY_TZONE", "hostSwitchName": "NVDS-1", "description": "SDDC_OVERLAY_TZONE", "transportType": "OVERLAY" } }, "logicalSwitchSpec": { "edgeOverlay": { "displayName": "EDGE_OVERLAY", "transportZone": "SDDC_VLAN_TZONE", "uplinkTeamingPolicyNames": "Edge_Transport", "vlan": "1100" }, "edgeUplink1": { "displayName": "EDGE_UPLINK1", "transportZone": "SDDC_VLAN_TZONE", "uplinkTeamingPolicyNames": "Uplink1_Only", "vlanRanges": { "start": 0, "end": 4094 } }, "edgeUplink2": { "displayName": "EDGE_UPLINK2", "transportZone": "SDDC_VLAN_TZONE", "uplinkTeamingPolicyNames": "Uplink2_Only", "vlanRanges": { "start": 0, "end": 4094 } } }, "routerSpec": { "tierZeroGateway": { "name": "T0", "haMode": "ACTIVE_STANDBY", "failOverMode": "NON_PREEMPTIVE", "description": "T0 gateway router for outboud connections.", "routeRedistributionTypes": [ "TIER0_NAT" ], "routeAdvertisementTypes": [ "TIER1_CONNECTED" ], "edgeUplink1TransportZoneSegment": { "name": "VLAN-UPLINK-SEGMENT-1", "description": "VLAN-UPLINK-SEGMENT-1-2100", "vlan": "2100" }, "edgeUplink2TransportZoneSegment": { "name": "VLAN-UPLINK-SEGMENT-2", "description": "VLAN-UPLINK-SEGMENT-2-2200", "vlan": "2200" }, "tierZeroInterfaces": [ { "name": "Uplink-I1", "ipAddressWithCidr": "172.16.1.1/24", "connectedWithSegment": "VLAN-UPLINK-SEGMENT-1", "placementEdgeNode": "edge1.cloud.vmw" }, { "name": "Uplink-I2", "ipAddressWithCidr": "172.16.2.1/24", "connectedWithSegment": "VLAN-UPLINK-SEGMENT-2", "placementEdgeNode": "edge1.cloud.vmw" }, { "name": "Uplink-I3", "ipAddressWithCidr": "172.16.1.2/24", "connectedWithSegment": "VLAN-UPLINK-SEGMENT-1", "placementEdgeNode": "edge2.cloud.vmw" }, { "name": "Uplink-I4", "ipAddressWithCidr": "172.16.2.2/24", "connectedWithSegment": "VLAN-UPLINK-SEGMENT-2", "placementEdgeNode": "edge2.cloud.vmw" } ] }, "tierOneGateway": { "name": "CGW", "failOverMode": "NON_PREEMPTIVE", "routeAdvertisementTypes": [ "TIER1_CONNECTED" ], "description": "Tier 1 Router for internal East-west SDDC overlay traffic.", "logicalOverlaySwitches": [ { "name": "WorkloadLS1", "description": "Segment for internal overlay Network.", "type": "ROUTED", "gatewayIpAddressWithCidr": "192.168.200.1/24", "internalNetwrokWithCidr": "192.168.200.0/24" } ] } }, "licenseKey": "" }, "portGrpSpecs": { "vmMgmt": { "type": "VM_MGMT", "vlan": 0 }, "vsan": { "type": "VSAN", "vlan": 0 }, "nsxTransport": { "type": "TRANSPORT_PG", "vlan": 0 }, "vmotion": { "type": "VMOTION_PG", "vlan": 0 }, "esxMgmt": { "type": "ESXi_MGMT", "vlan": 0 } }, "vsanSpec": { "license": "" }, "repoSpec": { "vc_url": "http://10.172.158.244:8080/vcps-sddc-bundle/vcenter/VMware-VCSA-all-6.7.0-14080392.iso", "nsx_unified_appliance_ova": "http://10.172.158.244:8080/vcps-sddc-bundle/nsxt/nsx-unified-appliance-2.5.0.0.0.14075120.ova", "base_repo_url": "http://10.172.158.244:8080", "hcx_cloud_ova_url": "https://172.17.11.3:8443/userContent/vcps/hcx/cloud/VMware-HCX-Cloud-3.5.1-14222959-all.ova", "hcx_enterprise_ova_url": "https://172.17.11.3:8443/userContent/vcps/hcx/enterprise/VMware-HCX-Enterprise-3.5.1-14222958-all.ova" }, "components": { "vcenter": { "build": "13950066", "version": "6.7.0.40000" }, "nsxt": { "build": "13952734", "version": "2.5.0.0.0" }, "esxi": { "build": "13962079", "version": "6.7.0-1.39" } }, "hcxSpec": { "hcxCloudDeploy": true, "hcxEnterpriseDeploy": false, "hcxCloudSpec": { "mgrCliPassword": "Skoda1!", "mgrRootPassword": "Skoda1!", "hostname": "192.168.101.99", "mgrIp": "192.168.101.99", "mgrGateway": "192.168.101.1", "systemName": "hcx-cloud", "diskMode": "thick", "publicAccessUrl": "https://hcx-cloudrs12.lab.vmw", "dataCenterLocation": { "city": "Dallas", "country": "United States", "province": "Texas", "latitude": "32.78306", "longitude": "-96.80667" }, "hcxActivation": { "url": "https://connect.hcx.vmware.com", "activationKey": "" }, "networkProfiles": { "mgmtNetworkProfile": { "portGroupName": "VM_MGMT", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [{ "startAddress": "192.168.101.115", "endAddress": "192.168.101.119" }], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] }, "vMotionNetworkProfile": { "portGroupName": "VMOTION_PG", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [{ "startAddress": "192.168.101.120", "endAddress": "192.168.101.123" }], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] }, "externalNetworkProfile": { "portGroupName": "ESXi_MGMT", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [ { "startAddress": "192.168.101.124", "endAddress": "192.168.101.127" } ], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] } }, "computeProfile": { "name": "CloudCP", "dataStore": "vsanDatastore", "resourcePool": "MGMT-ResourcePool", "switchName": "SDDC_OVERLAY_TZONE", "computeNetworkProfileTags": { "mgmtNetworkProfile": ["management", "replication"], "externalNetworkProfile": ["uplink"], "vMotionNetworkProfile": ["vmotion"] } } }, "hcxEnterpriseSpec": { "mgrCliPassword": "Skoda1!", "mgrRootPassword": "Skoda1!", "hostname": "192.168.101.99", "mgrIp": "192.168.101.99", "mgrIpPrefix": "24", "mgrGateway": "192.168.101.1", "systemName": "hcx-cloud", "diskMode": "thick", "publicAccessUrl": "https://hcx-cloudrs12.lab.vmw", "dataCenterLocation": { "city": "Dallas", "country": "United States", "province": "Texas", "latitude": "32.78306", "longitude": "-96.80667" }, "hcxEnterpriseCredentialSpec": { "username": "[email protected]", "password": "VMware123!" }, "hcxSitePairSpec": { "hcxCloudCredentialSpec": { "url": "https://192.168.101.6/", "username": "[email protected]", "password": "VMware123!" } }, "hcxServiceMeshSpec": { "name": "serviceMeshName", "cloudComputeProfileName": "", "enterpriseComputeProfileName": "", "enterpriseNetworkUplinkProfileName": "", "cloudNetworkUplinkProfileName": "" }, "datastore": "vsanDatastore", "hcxActivation": { "url": "https://connect.hcx.vmware.com", "activationKey": "" }, "networkProfiles": { "mgmtNetworkProfile": { "portGroupName": "VM_MGMT", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [{ "startAddress": "192.168.101.115", "endAddress": "192.168.101.119" }], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] }, "vMotionNetworkProfile": { "portGroupName": "VMOTION_PG", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [{ "startAddress": "192.168.101.120", "endAddress": "192.168.101.123" }], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] }, "externalNetworkProfile": { "portGroupName": "ESXi_MGMT", "switchName": "MGMT_DVS", "ipScopes": [{ "networkIpRanges": [ { "startAddress": "192.168.101.124", "endAddress": "192.168.101.127" } ], "gateway": "192.168.101.1", "primaryDns": "192.168.101.5" }] } }, "computeProfile": { "name": "sample", "dataStore": "vsanDatastore", "resourcePool": "MGMT-ResourcePool", "switchName": "SDDC_OVERLAY_TZONE", "computeNetworkProfileTags": { "mgmtNetworkProfile": ["management", "replication"], "externalNetworkProfile": ["uplink"], "vMotionNetworkProfile": ["vmotion"] } } } } }