Migrations of storage can cause the renaming of vCenter datastores. This in turn can result in issues, such as the absence of SEs for VIPs, loss of resiliency, no new VIP creation, and so on.
NSX Advanced Load Balancer supports the name change of datastores in vCenter.
NSX Advanced Load Balancer stores datastore names in SE groups exclusively.
After changing the name of the datastore, the
ManagedObjectId
of the datastore objects will remain the same in vCenter. Ensure you track the vCenterManagedObjectId
with its corresponding name in NSX Advanced Load Balancer.Operations in NSX Advanced Load Balancer will fall back to using the datastore name in the absence of
ManagedObjectId
in SE Group.
Configuring Datastore Name in Service Engine Groups
Configure Service Engine Group using datastore_name
and managed_object_id
commands as shown below:
[admin:10-102-96-215]: > configure serviceenginegroup TestSEG Updating an existing object. Currently, the object is: +-----------------------------------------+---------------------------------------------------------+ | Field | Value | +-----------------------------------------+---------------------------------------------------------+ | uuid | serviceenginegroup-6eec6635-bd09-41c7-9def-3220a6393b31 | | name | TestSEG | ...... [admin:10-102-96-215]: serviceenginegroup> vcenter_datastore_mode vcenter_datastore_shared Overwriting the previously entered value for vcenter_datastore_mode ..... [admin:10-102-96-215]: serviceenginegroup> vcenter_datastores datastore_name blr-01-vc13c01-vsan managed_object_id datastore-1042 New object being created [admin:10-102-96-215]: serviceenginegroup:vcenter_datastores> save [admin:10-102-96-215]: serviceenginegroup> vcenter_datastores_include Overwriting the previously entered value for vcenter_datastores_include [admin:10-102-96-215]: serviceenginegroup> save +-----------------------------------------+---------------------------------------------------------+ | Field | Value | +-----------------------------------------+---------------------------------------------------------+ | uuid | serviceenginegroup-6eec6635-bd09-41c7-9def-3220a6393b31 | | name | TestSEG | | max_vs_per_se | 10 | | min_scaleout_per_vs | 1 | | max_scaleout_per_vs | 4 | | max_se | 10 | | vcpus_per_se | 1 | | memory_per_se | 2048 | | disk_per_se | 15 gb | | max_cpu_usage | 80 percent | | min_cpu_usage | 30 percent | | se_deprovision_delay | 120 min | | auto_rebalance | False | | se_name_prefix | Avi | | vs_host_redundancy | True | | vcenter_folder | AviSeFolder | | vcenter_datastores[1] | | | datastore_name | blr-01-vc13c01-vsan | managed_object_id | datastore-1042 | | vcenter_datastores_include | True | | vcenter_datastore_mode | VCENTER_DATASTORE_SHARED |