There are two methods to configure certain networking resources for NCP. This section describes configuring resources in Manager mode.
In the NCP configuration file ncp.ini, you can specify NSX-T resources using their UUIDs or names.
Logical Routers and Logical switch
- Create a logical switch for the Kubernetes nodes, for example, LS1.
- Create a tier-0 logical router, for example, T0LR1. Set the tier0_router option in the [nsx_v3] section of ncp.ini with the logical router's ID if you do not have a shared tier-1 topology. See below for information on configuring a shared tier-1 topology. Set the HA mode to active-standby if you plan to configure NAT rules on this logical router. Otherwise, set it to active-active. Enable route redistribution. Also configure this router for access to the external network.
- Create a tier-1 logical router, for example, T1LR1. Connect this logical router to the tier-0 logical router.
- Configure router advertisement for T1LR1. At the very least, NSX-connected and NAT routes should be enabled.
- Connect T1LR1 to LS1. Make sure that the logical router port's IP address does not conflict with the IP addresses of the Kubernetes nodes.
- For each node VM, make sure that the vNIC for container traffic is attached to the logical switch that is automatically created. You can find it in the Networking tab with the same name as the logical switch, that is, LS1).
Tag | Scope |
---|---|
Node name | ncp/node_name |
Cluster name | ncp/cluster |
kubectl get nodes
If you want to extend the Kubernetes cluster while NCP is running, for example, add more nodes to the cluster, you must add the tags to the corresponding switch ports before running "kubeadm join". If you forget to add the tags before running "kubeadm join", the new nodes will not have connectivity. In this case, you must add the tags and restart NCP to resolve the issue.
/api/v1/fabric/virtual-machines
/api/v1/search -G --data-urlencode "query=(resource_type:VirtualMachine AND display_name:<node_vm_name>)"
/api/v1/search -G --data-urlencode \ "query=(resource_type:VirtualNetworkInterface AND external_id:<node_vm_ext_id> AND \ _exists_:lport_attachment_id)"
The lport_attachment_id attribute is the VIF ID for the node VM. You can then find the logical port for this VIF and add the required tags.
IP Blocks for Kubernetes Pods
Navigate to container_ip_blocks option in the [nsx_v3] section of ncp.ini to the UUIDs of the IP blocks.
to create one or more IP blocks. Specify the IP block in CIDR format. Set theBy default, projects share IP blocks specified in container_ip_blocks. You can create IP blocks specifically for no-SNAT namespaces (for Kubernetes) or clusters (for TAS) by setting the no_snat_ip_blocks option in the [nsx_v3] section of ncp.ini.
If you create no-SNAT IP blocks while NCP is running, you must restart NCP. Otherwise, NCP will keep using the shared IP blocks until they are exhausted.
When you create an IP block, the prefix must not be larger than the value of the subnet_prefix option in NCP's configuration file ncp.ini. The default is 24.
NCP will allocate additional subnets for a namespace if the originally allocated subnet is exhausted.
External IP Pools
An external IP pool is used for allocating IP addresses which will be used for translating pod IPs using SNAT rules, and for exposing Ingress controllers and LoadBalancer-type services using SNAT/DNAT rules, just like Openstack floating IPs. These IP addresses are also referred to as external IPs.
Navigate to external_ip_pools option in the [nsx_v3] section of ncp.ini to the UUIDs of the IP pools.
to create an IP pool. Set theMultiple Kubernetes clusters use the same external IP pool. Each NCP instance uses a subset of this pool for the Kubernetes cluster that it manages. By default, the same subnet prefix for pod subnets will be used. To use a different subnet size, update the external_subnet_prefix option in the [nsx_v3] section in ncp.ini.
You can change to a different IP pool by changing the configuration file and restarting NCP.
Shared Tier-1 Topology
- Set the top_tier_router option to the ID of either a tier-0 logical router or a tier-1 logical router. If it is a tier-1 logical router, you need to connect it to a tier-0 logical router for external connections. This option replaces the tier0_router option.
- If SNAT for Pod traffic is enabled, disconnect T1LR1 from LS1 (the logical switch for the Kubernetes nodes), and connect the tier-0 or tier-1 router set in top_tier_router to LS1.
- Set the single_tier_topology option to True. The default value is False.
(Optional) (For Kubernetes only) Firewall Marker Sections
To allow the administrator to create firewall rules and not have them interfere with NCP-created firewall sections based on network policies, navigate to
and create two firewall sections.Specify marker firewall sections by setting the bottom_firewall_section_marker and top_firewall_section_marker options in the [nsx_v3] section of ncp.ini.
The bottom firewall section must be below the top firewall section. With these firewall sections created, all firewall sections created by NCP for isolation will be created above the bottom firewall section, and all firewall sections created by NCP for policy will be created below the top firewall section. If these marker sections are not created, all isolation rules will be created at the bottom, and all policy sections will be created at the top. Multiple marker firewall sections with the same value per cluster are not supported and will cause an error.