You may see the purple diagnostic screen(PSoD) when upgrading from NSX-T Data Center 2.5.2.

Problem

When you run in-place upgrade from NSX-T Data Center 2.5.2, the purple diagnostic screen is displayed.

Cause

In-place upgrade from NSX-T Data Center 2.5.2 fails if any of the following features are enabled on the NSX-T Data Center host switch of the ESXi host:
  • LACP-based teaming is enabled for uplinks.
  • MAC learning is enabled on one or more logical ports.
  • NetQueue is enabled on one or more pNICs.

Solution

  • Use the maintenance mode when upgrading from NSX-T Data Center 2.5.2.
  • Disable MAC learning on all the logical ports and logical switches of the host switch.
  • Disable NetQueue on all the pNICs of the host switch prior to upgrade. You can then enable NetQueue after upgrade. For more information on disabling NetQueue, see VMware vSphere Documentation.