If you have a KVM host, you can use this procedure to attach VMs to NSX-T logical switches.

About this task

The example shown in this procedure shows how to attach a VM called app-vm to a logical switch called app-switch.

Prerequisites

  • The VM must be hosted on hypervisors that have been added to the NSX-T fabric.

  • The fabric nodes must have NSX-T management plane (MPA) and NSX-T control plane (LCP) connectivity.

  • The fabric nodes must be added to a transport zone.

  • A logical switch must be created.

Procedure

  1. From the KVM CLI, run the virsh dumpxml <your vm> | grep interfaceid command.
  2. In the NSX Manager UI, add a logical switch port, and use the VM's interface ID for the VIF attachment.

    For example:

Results

In the NSX Manager UI under Switching > Ports, find the VIF attachment ID and make sure that the Admin and Operational status are Up/Up.

If two VMs are attached to the same logical switch and have IP addresses configured in the same subnet, they should be able to ping each other.

What to do next

Add a logical router.

You can monitor the activity on the logical switch port to troubleshoot problems. See Monitor a Logical Switch Port Activity.