Describes a summary of alerts and events generated within the VMware SASE Orchestrator at the Enterprise level.

The document provides details about all Enterprise-level Orchestrator events. Although these events are stored within the SASE Orchestrator and displayed on the Orchestrator UI, most of them are generated by either an SD-WAN Edge or an SD-WAN Gateway and/or one of its running components (MGD, EDGED, PROCMON, and so on) with the exception of a few which are generated by the Orchestrator itself. You can configure notifications/alerts for events in Orchestrator only.

The following table provides an explanation for each of the columns in the "Enterprise-level Orchestrator Events" table:

Column name Details
EVENT Unique name of the event
DISPLAYED ON ORCHESTRATOR UI AS Specifies how the event is displayed on the Orchestrator.
SEVERITY The severity with which this event is usually generated.
GENERATED BY
The VMware SD-WAN component generating the notification can be one of the following:
  • SASE Orchestrator
  • SD-WAN Edge (MGD)
  • SD-WAN Edge (EDGED)
  • SD-WAN Edge (PROCMON)
GENERATED WHEN Technical reason(s) and circumstances under which this event is generated.
RELEASE ADDED IN The release this event was first added. If not specified, this event existed prior to release 2.5.
DEPRECATED Specifies if the event is deprecated from a specific release.

Enterprise-level Orchestrator Events

EVENT DISPLAYED ON ORCHESTRATOR UI AS SEVERITY GENERATED BY GENERATED WHEN RELEASE ADDED IN DEPRECATED
EDGE_UP Edge Up ALERT SASE Orchestrator Edge comes back after losing connectivity with the SASE Orchestrator through heartbeats. 2 consecutive heartbeats by an Edge causes the SASE Orchestrator to change its status to EDGE_UP. The SASE Orchestrator runs a monitor every 15 seconds that will update the status of all Edges.
EDGE_DOWN Edge Down ALERT SASE Orchestrator

Edge loses connectivity with the SASE Orchestrator and fails performing 2 or more consecutive heartbeats. The SASE Orchestrator runs a monitor every 15 seconds that will update the status of all Edges.

LINK_UP Link Up ALERT SASE Orchestrator A WAN Link returns to a normal functioning state.
LINK_DOWN Link Down ALERT SASE Orchestrator A WAN Link is disconnected from the Edge or when the Link cannot communicate with the Edge service.

VPN_TUNNEL_DOWN

VPN Tunnel Down

ALERT SASE Orchestrator The IPSec tunnel configured from the Edge service to your VPN Gateway cannot be established or if the tunnel is dropped and cannot be re-established.

EDGE_HA_FAILOVER

Edge HA Failover

ALERT SASE Orchestrator An HA Edge fails-over to its standby.

EDGE_SERVICE_DOWN

Edge Service Down

ALERT SASE Orchestrator The Edge service running on the SD-WAN Edge may be down. This may indicate Edge device failure or failure of network connectivity.

EDGE_CSS_TUNNEL_UP

Edge CSS Tunnel Up

ALERT SASE Orchestrator

A Cloud Security Service tunnel from Edge is UP.

EDGE_CSS_TUNNEL_DOWN

Edge CSS Tunnel Down

ALERT SASE Orchestrator

A Cloud Security Service tunnel from Edge is DOWN.

NVS_FROM_EDGE_TUNNEL_DOWN

NVS From Edge Tunnel Down

ALERT SASE Orchestrator

A NSD via Edge tunnel is DOWN.

NVS_FROM_EDGE_TUNNEL_UP

NVS From Edge Tunnel Up

ALERT SASE Orchestrator

A NSD via Edge tunnel is UP.

VNF_VM_DEPLOYED

VNF VM Deployed

ALERT SASE Orchestrator An Edge VNF virtual machine gets deployed on to the Edge.

VNF_VM_POWERED_ON

VNF VM Powered ON

ALERT SASE Orchestrator An Edge VNF virtual machine gets deployed on to the Edge and is powered on.

VNF_VM_POWERED_OFF

VNF VM Powered OFF

ALERT SASE Orchestrator An Edge VNF virtual machine is powered off.

VNF_VM_DEPLOYED_AND_POWERED_OFF

VNF VM Deployed and Powered OFF

ALERT SASE Orchestrator An Edge VNF virtual machine gets deployed on to the Edge and is immediately powered on.

VNF_VM_DELETED

VNF VM Deleted

ALERT SASE Orchestrator An Edge VNF virtual machine is removed from the Edge.

VNF_VM_ERROR

VNF VM error

ALERT SASE Orchestrator An error occurs during deployment of an Edge VNF virtual machine.

VNF_INSERTION_ENABLED

VNF insertion enabled

ALERT SASE Orchestrator Insertion of an Edge VNF virtual machine is enabled on the Edge.

VNF_INSERTION_DISABLED

VNF insertion

disabled
ALERT SASE Orchestrator Insertion of an Edge VNF virtual machine is deactivated on the Edge.

VNF_IMAGE_DOWNLOAD_IN_PROGRESS

VNF Image Download In Progress

ALERT SASE Orchestrator

An Edge VNF virtual machine image download is in progress.

VNF_IMAGE_DOWNLOAD_COMPLETED

VNF Image Download Completed

ALERT SASE Orchestrator

An Edge VNF virtual machine image download is completed.

VNF_IMAGE_DOWNLOAD_FAILED

VNF Image Download Failed

ALERT SASE Orchestrator

An Edge VNF virtual machine image failed to be downloaded on the Edge.

EDGE_BFD_NEIGHBOR_UP

BFD session established to Edge neighbor

INFO SASE Orchestrator A BFD session has been established to Edge neighbor.

EDGE_BFD_NEIGHBOR_DOWN

Edge BFD neighbor unavailable

INFO SASE Orchestrator A BFD session to Edge neighbor is not established.

EDGE_BFDV6_NEIGHBOR_UP

BFDv6 session established to Edge neighbor

INFO

SASE Orchestrator A BFDv6 session has been established to Edge neighbor. 4.5

EDGE_BFDV6_NEIGHBOR_DOWN

Edge BFDv6 neighbor unavailable

INFO SASE Orchestrator A BFDv6 session to Edge neighbor is not established. 4.5
EDGE_BGP_NEIGHBOR_UP BGP session established to Edge neighbor INFO SD-WAN Edge A BGP peer establishes tunnel with an SD-WAN Edge.
EDGE_BGP_NEIGHBOR_DOWN Edge BGP neighbor unavailable INFO SD-WAN Edge The Edge's BGP peer loses tunnel with the Edge.

EDGE_BGPV6_NEIGHBOR_UP

BGPv6 session established to Edge neighbor

INFO SASE Orchestrator A BGPv6 session has been established to Edge neighbor. 4.5

EDGE_BGPV6_NEIGHBOR_DOWN

BGPv6 session established to Edge neighbor

INFO SASE Orchestrator A BGPv6 session to Edge neighbor is not established. 4.5
GATEWAY_MIGRATION_CREATE Gateway Migration Created INFO SASE Orchestrator The self-service migration is activated. 4.5.0
GATEWAY_MIGRATION_REMOVE Gateway Migration Removed INFO SASE Orchestrator The self-service migration is deactivated. 4.5.0
GATEWAY_MIGRATION_STATE_CHANGE Gateway Migration State Changed INFO SASE Orchestrator The Gateway migration state is changed from one state to another. 4.5.0

PKI_PROMOTION

Endpoint PKI mode promoted

INFO SASE Orchestrator

An Edge's PKI mode has been changed from optional to required.

CERTIFICATE_REVOCATION

Certificate revoked

INFO SASE Orchestrator

Edge certificate revocation occurs intentionally or due to an expired certificate (The latter should rarely happen, given Edge certificates automatically renews after 30 days into the 90 day period).

CERTIFICATE_RENEWAL

Certificate renewal request

INFO SASE Orchestrator

Edge certificate automatically renews after 30 days into the 90 day period.

UPDATE_EDGE_IMAGE_MANAGEMENT

Update Edge image management

INFO SASE Orchestrator

Activates/deactivates management of Edge software images for a customer.

SET_EDGE_SOFTWARE

Updated Edge software image

INFO SASE Orchestrator

New software image is assigned to the Edge due to an Operator Profile reassignment or change in the software image within the operator profile.

UNSET_EDGE_SOFTWARE

Unset overridden Edge software image

INFO SASE Orchestrator

Unsetting software image overridden for the Edge and instead assign in the default software image associated with the Operator Profile.

ADD_OPERATOR_PROFILE

Added operator profile

INFO SASE Orchestrator

A new operator profile has been associated with this enterprise.

REMOVE_OPERATOR_PROFILE

Removed operator profile

INFO SASE Orchestrator

An existing operator profile has been removed from this enterprise.

ADD_SOFTWARE_IMAGE

Added software image

INFO SASE Orchestrator

When a new software image is associated to the operator profile for this enterprise.

MODIFY_ASSIGNED_OPERATOR_PROFILE_LIST

Modified the assigned operator profile list

INFO SASE Orchestrator

List of operator profiles associated with the Enterprise has been modified.

MODIFY_ASSIGNED_SOFTWARE_IMAGE_LIST

Modified the assigned software image list

INFO SASE Orchestrator

List of software images associated with the Enterprise has been modified.

CLOUD_SECURITY_ENABLE

Cloud Security enabled

INFO SASE Orchestrator

Cloud Security is activated in enterprise's profile or Edge-specific profile

CLOUD_SECURITY_DISABLE

Cloud Security disabled

INFO SASE Orchestrator

Cloud Security is deactivated in enterprise's profile

CLOUD_SECURITY_PROVIDER_DELETED

Cloud security provider deleted

INFO SASE Orchestrator

Cloud Security provider associated with an enterprise's profile has been deleted.

CLOUD_SECURITY_TUNNELING_PROTOCOL_CHANGE

Cloud Security Tunneling Protocol Change

INFO SASE Orchestrator

Cloud Security tunneling protocol changes (from IPSEC to GRE or vice versa) in an enterprise's profile

CLOUD_SECURITY_PROVIDER_ADDED

CLOUD_SECURITY_PROVIDER_ADDED

INFO SASE Orchestrator

Cloud Security provider associated with an Edge-specific profile has been added.

CLOUD_SECURITY_PROVIDER_REMOVED

CLOUD_SECURITY_PROVIDER_REMOVED

INFO SASE Orchestrator

Cloud Security provider associated with an Edge-specific profile has been removed.

CLOUD_SECURITY_OVERRIDE_ENABLED

CLOUD_SECURITY_OVERRIDE_ENABLED

INFO SASE Orchestrator

Cloud Security override has been activated in an Edge-specific profile.

CLOUD_SECURITY_OVERRIDE_DISABLED

CLOUD_SECURITY_OVERRIDE_DISABLED

INFO SASE Orchestrator

Cloud Security override has been deactivated in an Edge-specific profile.

CREATE_CLOUD_SERVICE_SITE

Cloud Security Service site creation enqueued

INFO SASE Orchestrator

An API automation job to create a Cloud Security Service tunnel from Edge has been enqueued.

UPDATE_CLOUD_SERVICE_SITE

Cloud Security Service site update enqueued

INFO SASE Orchestrator

An API automation job to update a Cloud Security Service tunnel from Edge has been enqueued.

DELETE_CLOUD_SERVICE_SITE

Cloud Security Service site deletion enqueued

INFO SASE Orchestrator

An API automation job to delete a Cloud Security Service tunnel from Edge has been enqueued.

ZSCALER_SUBLOCATION_ACTION_ENQUEUED

Zscaler Sub Location Edge action enqueued

INFO SASE Orchestrator

An API automation job for Cloud Security Service Zscaler Sub Location has been enqueued.

EDGE_NVS_TUNNEL_UP

Edge Direct IPsec tunnel up

INFO SASE Orchestrator

A Cloud Security Service tunnel or NSD via Edge tunnel is up.

EDGE_NVS_TUNNEL_DOWN

Edge Direct IPsec tunnel down

INFO SASE Orchestrator

A Cloud Security Service tunnel or NSD via Edge tunnel is down.

DIAGNOSTIC_REQUEST

New diagnostic bundle request

INFO SASE Orchestrator

A new Edge diagnostic bundle is requested by an enterprise or an operator user.

EDGE_DIRECT_SITE_DELETED

Edge direct site deleted

INFO SASE Orchestrator

A NSD via Edge tunnel has been deleted.

EDGE_DIRECT_TUNNELS_DISABLED

Edge direct tunnels

disabled
INFO SASE Orchestrator

NSD via Edge deactivated in profile device settings.

EDGE_DIRECT_TUNNELS_ENABLED

Edge direct tunnels enabled

INFO SASE Orchestrator

NSD via Edge enabled in profile device settings.

EDGE_DIRECT_TUNNEL_PROVIDER_DELETED

Edge direct tunnel provider deleted

INFO SASE Orchestrator

NSD via Edge provider associated with an enterprise's profile has been deleted.

CREATE_NVS_FROM_EDGE_SITE

NSD via Edge site creation enqueued

INFO SASE Orchestrator

An API automation job to create a NSD via Edge tunnel has been enqueued.

UPDATE_NVS_FROM_EDGE_SITE

NSD via Edge site update enqueued

INFO SASE Orchestrator

An API automation job to update a NSD via Edge tunnel has been enqueued.

DELETE_NVS_FROM_EDGE_SITE

NSD via Edge site deletion enqueued

INFO SASE Orchestrator

An API automation job to delete a NSD via Edge tunnel has been enqueued.

ENTERPRISE_ENABLE_VIEW_SENSITIVE_DATA

View sensitive data privileges granted

INFO SASE Orchestrator

An enterprise grants privileges to its MSP or the operator to view data (keys) information.

ENTERPRISE_ENABLE_OPERATOR_USER_MGMT

User management delegated to operator

INFO SASE Orchestrator

An enterprise has successfully delegated access to operator to manager its users.

ENTERPRISE_DISABLE_OPERATOR_ACCESS

User management access revoked from operator

INFO SASE Orchestrator

An enterprise revokes access that was previously delegated to operator to manage its entities.

ENTERPRISE_ENABLE_OPERATOR_ACCESS

Access delegated to operator

INFO SASE Orchestrator

An enterprise has successfully delegated access to operator to manager its entities.

ENTERPRISE_ENABLE_PROXY_ACCESS

Access revoked from operator

INFO SASE Orchestrator

An enterprise has successfully delegated access to partner to manager its entities.

ENTERPRISE_DISABLE_PROXY_ACCESS

Access delegated to partner

INFO SASE Orchestrator

An enterprise revokes access that was previously delegated to partner to manage its entities.

EDGE_TO_EDGE_VPN_DISABLE

Edge to Edge VPN Disabled

INFO SASE Orchestrator

Edge to Edge VPN associated with an Edge device or its corresponding profile has been deactivated.

EDGE_TO_EDGE_VPN_ENABLE

Edge to Edge VPN Enabled

INFO SASE Orchestrator

Edge to Edge VPN associated with an Edge device or its corresponding profile has been enabled.

VPN_DISABLE

Cloud VPN

disabled
INFO SASE Orchestrator

Cloud VPN settings associated with an Edge device or its corresponding profile has been deactivated.

VPN_ENABLE

Cloud VPN enabled

INFO SASE Orchestrator

When cloud VPN settings associated with an Edge device or its corresponding profile has been enabled.

VPN_UPDATE

Cloud VPN updated

INFO SASE Orchestrator

When cloud VPN settings associated with an Edge device or its corresponding profile has been updated with new modified.

REMOTE_ACTION

Edge remote action

INFO SASE Orchestrator

A remote action is performed on an online Edge.

RECURRING_REPORT_ERROR

Recurring report error

ERROR

SASE Orchestrator

When recurring report fails.

CREATE_COMPOSITE_ROLE

Composite Role Created

INFO SASE Orchestrator

When a composite role is created by an Enterprise, Partner, or Operator.

4.5

UPDATE_COMPOSITE_ROLE

Composite Role Updated

INFO SASE Orchestrator

When a composite role is updated by an Enterprise, Partner, or Operator.

4.5

DELETE_COMPOSITE_ROLE

Composite Role Deleted

INFO SASE Orchestrator

When a composite role is deleted by an Enterprise, Partner, or Operator.

4.5

ENQUEUE_CREATE_ZSCALER_SUBLOCATION

Zscaler Sub Location creation enqueued

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

ENQUEUE_UPDATE_ZSCALER_SUBLOCATION

Zscaler Sub Location update enqueued

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

ENQUEUE_DELETE_ZSCALER_SUBLOCATION

Zscaler Sub Location deletion enqueued

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

CREATE_ZSCALER_SUBLOCATION

Zscaler Sub Location object created

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

UPDATE_ZSCALER_SUBLOCATION

Zscaler Sub Location object updated

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

DELETE_ZSCALER_SUBLOCATION

Zscaler Sub Location object deleted

INFO SASE Orchestrator

When sublocation configuration of Edge device settings are modified.

4.5

ENQUEUE_UPDATE_ZSCALER_LOCATION

Zscaler Location update enqueued

INFO SASE Orchestrator

When location configuration of Edge device settings are modified.

4.5

CREATE_ZSCALER_LOCATION

Zscaler Location object created

INFO SASE Orchestrator

When location configuration of Edge device settings are modified.

4.5

UPDATE_ZSCALER_LOCATION

Zscaler Location object updated

INFO SASE Orchestrator

When location configuration of Edge device settings are modified.

4.5

DELETE_ZSCALER_LOCATION

Zscaler Location Object deleted

INFO SASE Orchestrator

When location configuration of Edge device settings are modified.

4.5
GATEWAY_BGP_NEIGHBOR_UP

BGP session established to Gateway neighbor

INFO SD-WAN Gateway When a BGP peer establishes tunnel with a Gateway.
GATEWAY_BGP_NEIGHBOR_DOWN Gateway BGP neighbor unavailable INFO SD-WAN Gateway When a Gateway's BGP peer loses tunnel with a Gateway.

VRF_MAX_LIMIT_EXCEEDED

VMware SD-WAN Partner Gateway: Maximum rules in a route map limit hit for enterprise <enterprise-name>

WARNING SD-WAN Gateway

Maximum inbound route map config limit reached.

VRF_ROUTEMAP_RULES_MAX_LIMIT_HIT

VMware SD-WAN Partner Gateway: Maximum rules in a route map limit hit for enterprise <enterprise-name>

WARNING SD-WAN Gateway

Maximum outbound route map config limit reached.

VRF_LIMIT_EXCEEDED

VMware SD-WAN gateway: Maximum VRF limit(1000) reached

ALERT SD-WAN Gateway

Maximum VRF limit reached for Partner Gateway.

GATEWAY_STARTUP

VMware SD-WAN gateway service started

INFO SD-WAN Gateway

Gateway daemon has started.

ZSCALER_MONITOR_DISABLED

Zscaler monitor disabled

CRITICAL

SD-WAN Edge/SD-WAN Gateway (PROCMON)

Unable to launch L7 health check daemon for CSS tunnels on Edge/Gateway. Or disabled due to too many failures.

4.4

ZSCALER_MONITOR_FAILED

Zscaler monitor failed

ERROR SD-WAN Edge/SD-WAN Gateway (PROCMON)

When L7 health check daemon fails with a return code.

4.4

MGD_EMERG_REBOOT

Rebooting system to recover from stuck process(es): <process name>

CRITICAL

SD-WAN Edge/SD-WAN Gateway (PROCMON)

Edge/Gateway is rebooted to recover from stuck processes by vc_procmon.

4.4

EDGE_SERVICES_STARTED/

GATEWAY_SERVICES_STARTED

Edge/Gateway Services Started

INFO

SD-WAN Edge/SD-WAN Gateway (PROCMON)

Generated when procmon starts the services.

4.5

EDGE_SERVICES_STOPPED/

GATEWAY_SERVICES_STOPPED

Edge/Gateway Services Stopped

INFO

SD-WAN Edge/SD-WAN Gateway (PROCMON)

Generated when procmon stops all the services.

4.5

EDGE_SERVICES_RESTARTED/

GATEWAY_SERVICES_RESTARTED

Edge/Gateway Services Restarted

INFO

SD-WAN Edge/SD-WAN Gateway (PROCMON) Generated when procmon restarts all the services. 4.5

EDGE_SERVICES_TERMINATED/

GATEWAY_SERVICES_TERMINATED

Edge/Gateway Services terminated

INFO

SD-WAN Edge/SD-WAN Gateway (PROCMON) Generated when procmon terminates all the services. 4.5

GATEWAY_SERVICE_DUMPED

Service gwd stopped for diagnostic memory dump

WARNING

SD-WAN Gateway (PROCMON)

Generated when gwd is stopped using SIGQUIT to generate core dump by user.

4.4

GATEWAY_MGD_SERVICE_FAILED

service mgd failed with error ....., restarting

ERROR SD-WAN Gateway (PROCMON)

Generated by vc_procmon on Gateway when MGD gets stopped.

4.4

GATEWAY_NAT_SERVICE_FAILED

Service natd failed with error ...., restarting

ERROR SD-WAN Gateway (PROCMON)

Generated by vc_procmon on Gateway when natd daemon gets stopped.

4.4

EDGE_DNSMASQ_FAILED

dnsmasq FAILED to start up

ERROR

SD-WAN Edge (PROCMON)

Generated when dnsmasq daemon failed to start up.

4.4

EDGE_SSH_LOGIN

sshd accepted connection

INFO SD-WAN Edge (PROCMON)

Generated whenever ssh login is done for accessing the Edge.

4.4

EDGE_SERVICE_DUMPED

Service edged stopped for diagnostic memory dump

WARNING

SD-WAN Edge (PROCMON)

Generated when Edge is stopped using SIGQUIT to generate core dump by user.

4.4

EDGE_LED_SERVICE_DISABLED

Edge front-panel LED service

disabled
WARNING, CRITICAL SD-WAN Edge (PROCMON)

LED service deactivated.

EDGE_LED_SERVICE_FAILED

Edge front-panel LED service failed

ERROR SD-WAN Edge (PROCMON) LED service failed.

EDGE_MGD_SERVICE_DISABLED

Management service disabled

CRITICAL

SD-WAN Edge (PROCMON)

Management service is unable to activate for too many failures.

EDGE_MGD_SERVICE_FAILED

Management service failed

ERROR

SD-WAN Edge (PROCMON) Management service failed.

EDGE_SERVICE_DISABLED

Edge data plane service

disabled

WARNING/CRITICAL

SD-WAN Edge (PROCMON)

Edge Data plane service is deactivated.

EDGE_SERVICE_ENABLED

Edge data plane service enabled

WARNING

SD-WAN Edge (PROCMON)

Edge Data plane service is activated by user from local UI.

EDGE_SERVICE_FAILED

Edge data plane service failed

ERROR SD-WAN Edge (PROCMON)

Edge Data plane service failed.

EDGE_VNFD_SERVICE_DISABLED

WARNING

SD-WAN Edge (PROCMON)

Edge VNFD service deactivated.

EDGE_VNFD_SERVICE_FAILED

ERROR SD-WAN Edge (PROCMON)

Edge VNFD service failed.

EDGE_DOT1X_SERVICE_DISABLED

Edge 802.1x service

disabled

WARNING,CRITICAL

SD-WAN Edge (PROCMON)

SD-WAN Edge 802.1x service is deactivated.

EDGE_DOT1X_SERVICE_FAILED

Edge 802.1x service failed

ERROR

SD-WAN Edge (PROCMON)

SD-WAN Edge 802.1x service failed.

EDGE_NYANSA_SYSLOG_SERVICE_FAILED

ERROR SD-WAN Edge (PROCMON)

Nyansa Syslog service failed.

EDGE_NYANSA_SYSLOG_SERVICE_DISABLED

WARNING SD-WAN Edge (PROCMON)

Nyansa Syslog service deactivated.

EDGE_NYANSA_AMOND_SERVICE_FAILED

ERROR SD-WAN Edge (PROCMON)

Nyansa Amond service failed.

EDGE_NYANSA_AMOND_SERVICE_DISABLED

WARNING SD-WAN Edge (PROCMON)

Nyansa Amond service deactivated

EDGE_NYANSA_SNMP_TRAPD_SERVICE_FAILED

ERROR SD-WAN Edge (PROCMON)

Nyansa SNMP Trapd service failed.

EDGE_NYANSA_SNMP_TRAPD_SERVICE_DISABLED

WARNING SD-WAN Edge (PROCMON)

Nyansa SNMP Trapd service deactivated.

EDGE_NYANSA_SNMP_READER_SERVICE_FAILED

ERROR SD-WAN Edge (PROCMON)

Nyansa SNMP Reader service failed.

EDGE_NYANSA_SNMP_READER_SERVICE_DISABLED

WARNING SD-WAN Edge (PROCMON)

Nyansa SNMP Reader service deactivated.

EDGE_USB_PORTS_ENABLED/

GATEWAY_USB_PORTS_ENABLED

Edge/Gateway USB ports Enabled

INFO SD-WAN Edge/SD-WAN Gateway (MGD)

Generated when USB ports is activated.

4.5

EDGE_USB_PORTS_DISABLED/

GATEWAY_USB_PORTS_DISABLED

Edge/Gateway USB ports Disabled

INFO SD-WAN Edge/SD-WAN Gateway (MGD)

Generated when USB ports is deactivated.

4.5

EDGE_USB_PORTS_ENABLE_FAILURE/

GATEWAY_USB_PORTS_ENABLE_FAILURE

Edge/Gateway USB ports Enable Failure

CRITICAL SD-WAN Edge/SD-WAN Gateway (MGD)

Generated when procmon activates USB ports failure.

4.5

EDGE_USB_PORTS_DISABLE_FAILURE/

GATEWAY_USB_PORTS_DISABLE_FAILURE

Edge/Gateway USB ports Disable Failure

CRITICAL SD-WAN Edge/SD-WAN Gateway (MGD) Generated when procmon deactivates USB ports failure. 4.5

VNF_VM_EVENT

VNF VM Event

INFO SD-WAN Edge (MGD)

Generated when VNF is powered on, powered off, deleted or deployed. Event detail will help distinguish the type.

VNF_INSERTION_EVENT

VNF insertion event

ALERT SD-WAN Edge (MGD)

VNF insertion is activated or deactivated. Event detail will help distinguish the type.

VNF_IMAGE_DOWNLOAD_EVENT

VNF image download event

INFO SD-WAN Edge (MGD)

VNF download is in progress, completed, or failed. Event detail will help distinguish the type.

MGD_START

Online

INFO

SD-WAN Edge (MGD)

Management daemon on Edge has started.

MGD_EXITING

Shutting Down

INFO

SD-WAN Edge (MGD)

Management service on a SD-WAN Edge is shutting down for a restart.

MGD_SET_CERT_SUCCESS

Set Certificate Successful

INFO SD-WAN Edge (MGD)

New PKI certificate for Orchestrator communication is installed successfully on a SD-WAN Edge.

MGD_SET_CERT_FAIL

Set Certificate Failed ERROR SD-WAN Edge (MGD)

Installation of a new PKI certificate for Orchestrator communication on a SD-WAN Edge has failed.

MGD_CONF_APPLIED

Configuration Applied

INFO SD-WAN Edge (MGD)

Configuration change made on the Orchestrator has been pushed to SD-WAN Edge and is successfully applied.

MGD_CONF_PENDING

New configuration pending

INFO SD-WAN Edge (MGD)

New configuration is pending application (This event is currently NOT generated anywhere)

MGD_CONF_ROLLBACK

Bad configuration rolled back

CRITICAL

SD-WAN Edge (MGD)

Configuration policy sent from the Orchestrator had to be rolled back because it destabilized the SD-WAN Edge.

MGD_CONF_FAILED

Failed to apply configuration

ERROR

SD-WAN Edge (MGD)

Edge failed to apply a configuration change made on the Orchestrator.

MGD_CONF_UPDATE_INVALID

Invalid software update configuration

WARNING

SD-WAN Edge (MGD)

Edge has been assigned an Operator Profile with an invalid software image that the Edge cannot use.

MGD_DEVICE_CONFIG_WARNING

WARNING

SD-WAN Edge (MGD)

Inconsistent device settings are detected. MGD continues with warnings.

MGD_DEVICE_CONFIG_ERROR

ERROR SD-WAN Edge (MGD)

Invalid device settings are detected by MGD.

MGD_SWUP_IGNORED_UPDATE

Software update ignored

INFO SD-WAN Edge (MGD)

Software update is ignored at the activation time, because SD-WAN Edge is already running that version.

MGD_SWUP_INVALID_SWUPDATE

Invalid software update

WARNING SD-WAN Edge (MGD)

Software update package received from the Orchestrator is invalid.

MGD_SWUP_DOWNLOAD_FAILED

Software download failed

ERROR SD-WAN Edge (MGD)

Download of an Edge software update image has failed.

MGD_SWUP_UNPACK_FAILED

Software update unpack failed

ERROR SD-WAN Edge (MGD)

Edge has failed to unpack the downloaded software update package.

MGD_SWUP_INSTALL_FAILED

Software update install failed

ERROR SD-WAN Edge (MGD)

Edge software update installation failed.

MGD_SWUP_INSTALLED

Software update

INFO SD-WAN Edge (MGD)

Software update was successfully downloaded and installed.

MGD_SWUP_REBOOT

Restart after software update

INFO SD-WAN Edge (MGD)

Edge is being rebooted after a software update.

MGD_SWUP_STANDBY_UPDATE_START

Standby device software update started

INFO SD-WAN Edge (MGD)

Edge send upgrade message to standby when it detect peer software version is not same with Active Edge or Active Edge received upgrade command from SASE Orchestrator.

MGD_SWUP_STANDBY_UPDATE_FAILED

Standby device software update failed

ERROR SD-WAN Edge (MGD)

Active Edge report standby upgrade failed if it fail to send upgrade command to peer or standby fail to upgrade for more than 5 minutes

MGD_SWUP_STANDBY_UPDATED

Standby device software update completed

INFO SD-WAN Edge (MGD)

When Active Edge detects standby comes up with expected image version

MGD_VCO_ADDR_RESOLV_FAILED

Cannot resolve Orchestrator address

WARNING SD-WAN Edge (MGD)

DNS resolution of the Orchestrator address failed.

MGD_DIAG_REBOOT

User-initiated restart

INFO SD-WAN Edge (MGD)

Edge is rebooted by a Remote Action from the Orchestrator.

MGD_DIAG_RESTART

Services restarted

INFO SD-WAN Edge (MGD)

Data plane service on the SSD-WAN Edge is restarted by a Remote Action from the Orchestrator.

MGD_SHUTDOWN

Powered off

INFO SD-WAN Edge (MGD)

Edge diagnostic shutdown based on user request.

MGD_HARD_RESET

Reset to factory defaults

INFO SD-WAN Edge (MGD)

Edge is restored to its factory-default software and configuration.

MGD_DEACTIVATED

Deactivated

INFO SD-WAN Edge (MGD)

Edge is deactivated based on user request by mgd.

MGD_NETWORK_SETTINGS_UPDATED

Network settings updated

INFO SD-WAN Edge (MGD)

Network settings are applied to a SD-WAN Edge.

MGD_NETWORK_MGMT_IF_BROKEN

Management Network incorrectly set up ALERT SD-WAN Edge (MGD)

Management network is set up incorrectly.

MGD_NETWORK_MGMT_IF_FIXED

Network was restarted twice to fix Management Network inconsistency

WARNING

SD-WAN Edge (MGD)

Network is restarted twice to fix the Management Network inconsistency.

MGD_INVALID_VCO_ADDRESS

Unable to heartbeat to new VCO %(newprimary)s, keep talking to old VCO %(oldprimary)s

WARNING

SD-WAN Edge (MGD)

Invalid address for Orchestrator was sent in a management plane policy update and was ignored.

MGD_ACTIVATION_PARTIAL

Activation incomplete

INFO SD-WAN Edge (MGD)

Edge is activated partially, but a software update failed.

MGD_REBOOT_DIAG_BUNDLE

Generating diagnostic bundle before reboot

INFO SD-WAN Edge (MGD) When the diagnostic bundle is generated before reboot. 5.0

MGD_ACTIVATION_SUCCESS

Activated

INFO SD-WAN Edge (MGD)

Edge has been activated successfully.

MGD_ACTIVATION_ERROR

Activation failed

ERROR SD-WAN Edge (MGD)

Edge activation failed. Either the activation link was not correct, or the configuration was not successfully downloaded to the Edge.

MGD_HA_TERMINATED

HA disabled on Edge

INFO SD-WAN Edge (MGD)

Standby Edge send this event when HA is deactivated.

EDGE_INTERFACE_DOWN

Edge Interface Down

INFO SD-WAN Edge (MGD)

Generated by hotplug scripts when the interface is down.

EDGE_INTERFACE_UP

Edge Interface Up

INFO SD-WAN Edge (MGD)

Generated by hotplug scripts when the interface is up.

EDGE_KERNEL_PANIC

ALERT SD-WAN Edge (MGD)

Edge operating system has encountered a critical exception and must reboot the Edge to recover. An Edge reboot is disruptive to customer traffic for 2-3 minutes while the Edge completes the reboot.

MGD_MFRMUP_IGNORED_UPDATE

Modem Firmware update ignored: <error message>

ALERT SD-WAN Edge (MGD) Generated when modem firmware update is ignored. 5.0

MGD_MFRMUP_INVALID_MFRMUPDATE

Invalid Modem Firmware update applied: <error message>

INFO SD-WAN Edge (MGD) Generated when invalid modem firmware update is applied. 5.0

MGD_MFRMUP_INCOMPATIBLE_UPDATE

In compatible Device or Factory Image: <error message>

WARNING SD-WAN Edge (MGD) Generated when the device is incompatible for modem firmware update. 5.0

MGD_MFRMUP_DOWNLOAD_FAILED

Error downloading MFW ver <version> <build>

WARNING SD-WAN Edge (MGD) Generated when error occurs downloading the modem firmware update version. 5.0

MGD_MFRMUP_UNPACK_FAILED

Error unpacking MFW ver <version> bu <build>

ERROR SD-WAN Edge (MGD) Generated when the modem firmware update unpacking failed. 5.0

MGD_MFRMUP_INSTALL_FAILED

Error installing MFW ver <version> bu <build>

ERROR SD-WAN Edge (MGD) Generated when the modem firmware update installation failed. 5.0

MGD_MFRMUP_INSTALLED

Installed downloaded MFW ver <version> bu <build>

ERROR SD-WAN Edge (MGD) Generated when the modem firmware update version is installed. 5.0

MGD_MFRMUP_UPGRADE_PROGRESS

MFW update in progress ver <version> bu <build>

INFO SD-WAN Edge (MGD) Generated when the modem firmware upgrade is in progress. 5.0

MGD_MFRMUP_REBOOT

Edge is restarting into new MFW version <version> build <build>

INFO SD-WAN Edge (MGD) Generated when the Edge restarts with new modem firmware update version. 5.0

MGD_MFRMUP_STANDBY_UPDATE_START

Begin HA Standby update with new MFW

INFO SD-WAN Edge (MGD) Generated when the HA Standby update with new modem firmware version started. 5.0

MGD_MFRMUP_STANDBY_UPDATE_FAILED

Failed HA Standby update with new MFW

ERROR SD-WAN Edge (MGD) Generated when the HA Standby update with new modem firmware version failed. 5.0

MGD_MFRMUP_STANDBY_UPDATED

Succeeded HA Standby update with new MFW

INFO SD-WAN Edge (MGD) Generated when the HA Standby update with new modem firmware version succeeded. 5.0

EDGE_OSPF_NSM

Edge OSPF NSM Event

INFO SD-WAN Edge (EDGED)

Edge send this event when OSPF neighbor state changes.

IP_SLA_PROBE

IP SLA Probe

INFO SD-WAN Edge (EDGED)

Edge generates when IPSLA state changes.

IP_SLA_RESPONDER

IP SLA Responder ALERT, INFO SD-WAN Edge (EDGED)

When IPSLA responder state changes from up to down and vice versa.

ALL_CSS_DOWN

ALL_CSS_DOWN

ALERT SD-WAN Edge (EDGED)

When all CSS paths go down.

CSS_UP

CSS_UP

ALERT SD-WAN Edge (EDGED)

When at least one CSS path is up.

LINK_MTU

Link MTU detected

INFO SD-WAN Edge (EDGED)

Link MTU detected. The Gateway has detected the MTU for this WAN link and all traffic sent on this link will account for that MTU reading. For Release 3.2.x and earlier, VeloCloud software uses RFC 1191 Path MTU Discovery, which relies on receiving an ICMP error (fragmentation needed) from an upstream device in order to discover the MTU. On Release 3.3.x and later, the Path MTU Discovery has been enhanced to use packet layer Path MTU Discovery (RFC 4821).

PORT_SCAN_DETECTED

Port scan detected

INFO SD-WAN Edge (EDGED)

If Stateful firewall detects host scanning then this event would be logged along with the IP address and port number.

PEER_UNUSABLE

Peer unusable

ALERT SD-WAN Edge (EDGED) Peer is unusable. Deprecated

PEER_USABLE

Peer usable

INFO SD-WAN Edge (EDGED) Peer is usable. Deprecated

BW_UNMEASURABLE

Error measuring bandwidth

ALERT SD-WAN Edge (EDGED)

Bandwidth measurement failed to the Primary Gateway. Reattempt at measurement in 30minutes. Reasons include a link suffering some quality issue like excessive loss or latency. This message should only be seen on Edge's using Release 3.1.x or lower as this was removed beginning with Edge Release 3.2.0.

SLOW_START_CAP_MET

Bandwidth measured exceeds the slow start cap. Moving to burst mode.

NOTICE

SD-WAN Edge (EDGED)

Bandwidth measurement Slow-start limit of 175 Mbps exceeded. Link will be remeasured in Burst mode to ensure the correct measurement of a 175+ Mbps WAN link.

EDGE_BFD_CONFIG

INFO SD-WAN Edge (EDGED)

BFD configured with incorrect local address.

FLOOD_ATTACK_DETECTED

INFO SD-WAN Edge (EDGED)

Generated when a malicious host floods the SD-WAN Edge with new connections.

LINK_ALIVE

Link alive

INFO SD-WAN Edge (EDGED)

When link state (link_fsm) becomes alive.

LINK_DEAD

Link dead

ALERT SD-WAN Edge (EDGED)

When link state (link_fsm) becomes dead.

LINK_USABLE

Link usable

INFO SD-WAN Edge (EDGED)

When link state (link_fsm) becomes usable.

LINK_UNUSABLE

Link unusable

ALERT SD-WAN Edge (EDGED)

When link state (link_fsm) becomes unusable.

VPN_DATACENTER_STATUS

VPN Tunnel state change

INFO, ERROR SD-WAN Edge (EDGED)

VPN Tunnel state change.

INTERFACE_CONFIG_ERROR

Interface config error ALERT SD-WAN Edge (EDGED)

HA_STANDBY_ACTIVATED

HA Standby Activated

INFO SD-WAN Edge (EDGED)

When active Edge detects standby peer send this event to SASE Orchestrator to activate standby Edge.

HA_INTF_STATE_CHANGED

HA Interface State Changed ALERT SD-WAN Edge (EDGED)

HA interface went down/up.

HA_GOING_ACTIVE

High Availability Going Active

INFO SD-WAN Edge (EDGED)

Standby Edge transition to Active Edge after detecting no heartbeat for more than 700ms.

HA_FAILED

High Availability Peer State Unknown

INFO SD-WAN Edge (EDGED)

Active Edge detects no heartbeat or activity from standby Edge for more than 700 milliseconds.

HA_READY

High Availability Ready

INFO SD-WAN Edge (EDGED)

Active Edge detects activated standby peer.

VCO_IDENTIFIED_HA_FAILOVER Edge HA Failover Identified ALERT SASE Orchestrator Orchestrator has detected that a High Availability failover has occurred on the Edge. 5.2
VCO_IDENTIFIED_HA_FAILURE Edge HA Failure Identified ALERT SASE Orchestrator Orchestrator has detected that the Standby Edge has gone down. 5.2
HA_UPDATE_FAILOVER_TIME Updating HA Failover time from ####ms to ####ms INFO SASE Orchestrator User changed the failover time for when an HA Edge will failover due to a lack of heartbeat response. This time is measured in milliseconds (ms). 5.2
HA_RESET_FAILOVER_TIME Failover time reset from ####ms to ####ms. INFO SD-WAN Edge (EDGED) When an HA Edge's system has been stable for 60 seconds, the process reduces the failover time by 50%. 5.2

HA_WAN_LINK_ACTIVE

<Edge-Name> <Active Serial Number> configured with <Standard, Enhanced, or Mixed-Mode> HA, with WAN <Link ID> is <Down or Up> ALERT SD-WAN Edge (EDGED) For all HA topologies (Standard, Enhanced, and Mixed-Mode) when the WAN interface goes Up or Down on the Active Edge. 5.2

HA_WAN_LINK_STANDBY

<Edge-Name> <Standby Serial Number> configured with <Standard, Enhanced, or Mixed-Mode> HA, with WAN <Link ID> is <Down or Up> ALERT SD-WAN Edge (EDGED) For all HA topologies (Standard, Enhanced, and Mixed-Mode) when the WAN interface goes Up or Down on the Standby Edge. 5.2

HA_LAN_LINK_ACTIVE

<Edge-Name> <Active Serial Number> configured with <Standard, Enhanced, or Mixed-Mode> HA, with WAN <Link ID> is <Down or Up>

ALERT SD-WAN Edge (EDGED)

For all HA topologies (Standard, Enhanced, and Mixed) when the LAN interface goes Up or Down on the Active Edge.

5.2

HA_LAN_LINK_STANDBY

<Edge-Name> <Standby Serial Number> configured with <Standard, Enhanced, or Mixed-Mode> HA, with LAN <Link ID> is <Down or Up>

ALERT SD-WAN Edge (EDGED) For all HA topologies (Standard, Enhanced, and Mixed) when the LAN interface goes Up or Down on the Standby Edge. 5.2
HA_SPLIT_BRAIN_DETECTED HA split-brain detected, peer will restart ALERT SASE Orchestrator The Orchestrator has detected that both HA Edges are in an Active state. This is known as an Active-Active or Split Brain state. If other methods of preventing a Split-Brain state are not successful, the Orchestrator resolves this by triggering a restart of the Standby Edge (listed here as "peer") that is erreneously functioning as Active. 5.2
HA_SPLITBRAIN_RESOLVED HA split-brain resolved, peer will move to standby state NOTICE SASE Orchestrator The Standby Edge (listed here as "peer") in an Active state has completed its restart and is demoted back to its correct Standby state. As a result, the Active-Active or Split Brain state is resolved. 5.2
FW_UPGRADE_PENDING - CPLD CPLD Firmware being updated during software upgrade - edge may be offline for 3 - 5 minutes. INFO SASE Orchestrator A firmware upgrade action has been initiated and sent by the Orchestrator to the Edge. 5.2
FW_UPGRADE_SUCCESS

Note - that an edge physical reboot was required due to the edge not responding once the PENDING message was received.

INFO SD-WAN Edge(EDGED) The Edge firmware upgrade was successful and required Edge reboots to complete. 5.2

MGD_UNREACHABLE

Management Proxy unreachable

EMERGENCY

SD-WAN Edge (EDGED)

Data plane process could not communicate to the management plane proxy.

VRRP_INTO_MASTER_STATE

VRRP HA updated to Primary state

INFO SD-WAN Edge (EDGED)

VRRP get into Primary state

VRRP_OUT_OF_MASTER_STATE

VRRP HA updated out of Primary state

INFO SD-WAN Edge (EDGED)

VRRP get out of Primary state.

VRRP_FAIL_INFO

VRRP failed

INFO SD-WAN Edge (EDGED)

VRRP failed.

EDGE_HEALTH_ALERT

Edge Health Alert

EMERGENCY

SD-WAN Edge (EDGED)

Data plane is unable to allocate necessary resources for packet processing.

EDGE_STARTUP

Edge service startup

INFO SD-WAN Edge (EDGED)

Edge is running in mgmt-only mode.

EDGE_DHCP_BAD_OPTION

Invalid DHCP Option

WARNING SD-WAN Edge (EDGED)

SD-WAN Edge is configured with an invalid DHCP option.

EDGE_NEW_USER

New client user seen

INFO SD-WAN Edge (EDGED)

New or updated client user detected on a given MAC address.

EDGE_NEW_DEVICE

New client device seen

INFO SD-WAN Edge (EDGED)

A new device is detected during DHCP.

INVALID_JSON

CRITICAL SD-WAN Edge (EDGED)

The Edged received invalid json data from the mgd.

QOS_OVERRIDE

QoS override

INFO SD-WAN Edge (EDGED)

Remote diagnostics is performed to flip cloud traffic to be routed according to business policy OR sent to the Gateway OR or bypass the Gateway.

EDGE_L2_LOOP_DETECTED

Edge L2 loop detected

ERROR SD-WAN Edge (EDGED)

Edge L2 loop is detected.

EDGE_TUNNEL_CAP_WARNING

Edge Tunnel CAP warning

WARNING

SD-WAN Edge (EDGED)

Edge has reached its maximum tunnel capacity.

Interface LoS

LoS no longer seen on interface <iface-name>/

LoS detected on interface <iface-name>

ALERT SD-WAN Edge (EDGED)

Loss of Signal state changed on the interface in HA setup.

4.4

EDGE_LOCALUI_LOGIN

Edge Local UI Login

INFO SD-WAN Edge

LOCAL UI login is successful for a user.

EDGE_MEMORY_USAGE_ERROR

Memory Usage Critical

ERROR SD-WAN Edge

Resource Monitor process detects Edge memory utilization has exceeded defined thresholds and reaches 70% threshold. The Resource Monitor waits for 90 seconds to allow the Edged process to recover from a possible temporary spike in memory usage. If memory usage persists at a 70% or higher level for more than 90 seconds, the Edge will generate this error message and send this event to the Orchestrator.

EDGE_MEMORY_USAGE_WARNING

Memory Usage Warning

WARNING SD-WAN Edge

Resource Monitor process detects Edge memory utilization is 50% or more of the available memory. This event will be sent to the Orchestrator every 60 minutes until the memory usage drops under the 50% threshold.

EDGE_RESTARTING

User-initiated Edge service restart

WARNING

SD-WAN Edge

User initiates an Edge service restart.

EDGE_REBOOTING

User-initiated Edge reboot

WARNING

SD-WAN Edge

User initiates an Edge reboot.

EDGE_HARD_RESET

User-initiated Edge hard reset

WARNING

SD-WAN Edge

Edge hard reset

EDGE_DEACTIVATED

Edge deactivated

WARNING

SD-WAN Edge

SD-WAN Edge has all its configuration cleared and is not associated with a customer site. The software build remains unchanged.

EDGE_CONSOLE_LOGIN

Edge console login

INFO SD-WAN Edge

SD-WAN Edge login via console port.

EDGE_COMMAND

Edge Command

INFO SD-WAN Edge

Generated by a SD-WAN Edge during remote diagnostics when executing Edge commands.

EDGE_BIOS_UPDATED

Edge BIOS updated

INFO SD-WAN Edge

Generated by 12-upgrade-bios.sh script when SD-WAN Edge BIOS is successfully updated.

EDGE_BIOS_UPDATE_FAILED

Edge BIOS update failed

ERROR SD-WAN Edge

Generated by 12-upgrade-bios.sh script when SD-WAN Edge BIOS update failed.

IPV6_ADDR_DELETED

Deleted IPv6 address <v6addr> on interface/sub-interface <iface/subiface name>

INFO SD-WAN Edge/SD-WAN Gateway

When IPv6 interface is deleted on interface or sub-interface.

4.4

IPV6_NEW_ADDR_ADDED

Added new IPv6 address <v6-addr> on interface <ifacename>

INFO SD-WAN Edge

When IPv6 address is added on interface.

4.4

IPV6_ADDR_DEPRECATED

Deprecated IPv6 address <v6-addr> on interface <iface-name>

INFO SD-WAN Edge

When IPv6 address gets deprecated on an interface.

4.4

IPV6_ADDR_PREFERRED

Preferred IPv6 address <v6-addr> on interface <iface-name>

INFO SD-WAN Edge

When IPv6 address moves from Deprecated state to Preferred state.

4.4

NDP_MAC_ADDR_CHANGE

Neighbor MAC address change detected in interface <iface-name>

INFO SD-WAN Edge

When IPv6 neighbor MAC address change is detected.

4.4

EDGE_INTF_CONFIG

DAD Failed for IPv6 Address <v6-addr> in interface <iface-name>

INFO SD-WAN Edge

When IPv6 NDP DAD is failed.

4.4

EDGE_SHUTTING_DOWN

Edge is shutting down - must be restarted by power-cycling

WARNING

SD-WAN Edge (LUA Backend)

When Edge is shutting down. 4.4

BIOS_PHY_RESET_CMOS_SET

BIOS - Phy reset CMOS bit is set/

BIOS - Phy reset CMOS bit cannot be set

WARNING

SD-WAN Edge When CMOS (BIOS) is reset to its factory default settings. 4.4

FW_UPGRADE_PENDING

CPLD Firmware being updated during software upgrade - edge may go offline for 3-5 minutes

WARNING

SD-WAN Edge When CPLD Firmware is being updated during software upgrade. 4.4

EVDSL_IFACE_UP_EVENT

Contains json string with evdslModem name, status, serial number

INFO SD-WAN Edge

Generated when EVDSL interface moves to Up state.

4.5

EVDSL_IFACE_DOWN_EVENT

contains json string with evdslModem name, status, serial number

INFO SD-WAN Edge

Generated when EVDSL interface moves to Down state.

4.5

NAT_PORT_ASSIGN_FAIL

NAT Ports exhausted from <src_ip> to <dst_ip>:<dport>

WARNING SD-WAN Edge/SD-WAN Gateway

Generated when NAT port allocation range is exhausted.

4.5

IPV6_MAX_DAD_FAILED

IPv6 < link local / RA > stable secret address generation failed on interface <iface name> after multiple DAD failures

ALERT SD-WAN Edge

Generated when we fail to generate stateless IPv6 address after multiple DAD failures.

4.5

IPV6_ADDR_GEN_FAILED

IPv6 <link local / RA> stable secret address generation failed on interface <iface name> after generating multiple invalid addresses

ALERT SD-WAN Edge Generated when IPv6 stable secret address generation failed on interface after generating multiple invalid addresses. 4.5

INVALID_STATIC_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid static route.

4.5

INVALID_OSPF_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid OSPF routes.

4.5

INVALID_BGP_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid BGP routes.

4.5

INVALID_REMOTE_OSPF_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid remote OSPF route.

4.5

INVALID_REMOTE_BGP_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid remote BGP route.

4.5

INVALID_OVERLAY_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid Overlay route.

4.5

INVALID_ROUTE

Rejected invalid routes <route-prefix>/0 flag <route flags in hex>

ALERT SD-WAN Edge

Generated for invalid routes.

4.5

EDGE_BFDv6_CONFIG

Incorrect local address <IP address>. IP Address not present

INFO SD-WAN Edge

Generated when invalid IPv6 BFD configuration is received.

4.5

EDGE_USB_DEVICE_INSERTED

Edge USB device inserted

ALERT SD-WAN Edge

Generated when USB device is inserted.

4.5

EDGE_USB_DEVICE_REMOVED

Edge USB device removed

ALERT SD-WAN Edge

Generated when USB device is removed.

4.5

WIFI_CARD_DEAD

Wificard <device name> at <port> is no longer usable , reboot required to recover

EMERGENCY

SD-WAN Edge

Generated when WiFi card at a port is no longer usable.

4.5

DNS_CACHE_LIMIT_REACHED

DNS Cache Max Limit (<cache limit of the edge>) Reached

ALERT SD-WAN Edge

Generated when DNS cache limit is reached on the Edge.

4.5.1, 5.0
PEER_MISMATCH PEER_MISMATCH ALERT SD-WAN Edge (EDGED) When there is a peer name mismatch between MP_INIT_REQ and MP_INIT_ACK during Edge and Gateway tunnel creation. 5.1
EDGE_CONGESTED Congestion alert due to either a high number of packet drops/scheduler drops WARNING SD-WAN Edge (EDGED)
  • The number of packet drops (xxxx) is above the congestion threshold (1000)

    or

  • "The number of scheduler drops (xxxx) is above the congestion threshold (1000)"
Generated if there are either:
  • Continuous packet drops above a threshold of 1000 for more than 30 seconds due to over capacity.
  • Continuous packet drops above a threshold of 1000 for more than 30 seconds at the schedulers.
5.1
EDGE_STABLE Congestion due to a high number of packet drops/scheduler drops subsided NOTICE SD-WAN Edge (EDGED)
  • "The number of packet drops (xxx) is within the acceptable threshold (1000)"

    or

  • "The number of scheduler drops (xxx) is within the acceptable threshold (1000)"
Follow up to the EDGE_CONGESTED event, indicating that the triggering criteria has subsided and the Edge is operating within acceptable parameters.
5.1

MGD_ATPUP_INVALID_IDPS_SIGNATURE

MGD_ATPUP_INVALID_IDPS_SIGNATURE

ERROR

SD-WAN Edge (MGD)

Generated when there is an invalid suricata package.

5.2

MGD_ATPUP_DOWNLOAD_IDPS_SIGNATURE_FAILED

MGD_ATPUP_DOWNLOAD_IDPS_SIGNATURE_FAILED

ERROR

SD-WAN Edge (MGD)

Generated when downloading of suricata package fails.

5.2

MGD_ATPUP_DECRYPT_IDPS_SIGNATURE_FAILED

MGD_ATPUP_DECRYPT_IDPS_SIGNATURE_FAILED

ERROR

SD-WAN Edge (MGD) Generated when unpacking of suricata package fails. 5.2

MGD_ATPUP_APPLY_IDPS_SIGNATURE_FAILED

MGD_ATPUP_APPLY_IDPS_SIGNATURE_FAILED

ERROR

SD-WAN Edge (MGD)

Generated due to error in applying Suricata files.

5.2

MGD_ATPUP_APPLY_IDPS_SIGNATURE_SUCCEEDED

MGD_ATPUP_APPLY_IDPS_SIGNATURE_SUCCEEDED

INFO SD-WAN Edge (MGD)

Generated when suricata files are successfully applied.

5.2

MGD_ATPUP_STANDBY_UPDATE_START

MGD_ATPUP_STANDBY_UPDATE_START

INFO SD-WAN Edge (MGD)

Generated when HA Standby update with new EFS IDPS Signature version is started.

5.2

MGD_ATPUP_STANDBY_UPDATE_FAILED

MGD_ATPUP_STANDBY_UPDATE_FAILED

ERROR SD-WAN Edge (MGD)

Generated when HA Standby update with new EFS IDP Signature version fails.

5.2

MGD_ATPUP_STANDBY_UPDATED

MGD_ATPUP_STANDBY_UPDATED

INFO SD-WAN Edge (MGD)

Generated when HA Standby update with new EFS IDPS Signature version is successfully applied.

5.2