Simple certification involves only in configure file changes and the qualification of new OID in the currently existing driver. This section describes the devices certified in this patch.
Simple devices certified in the patch:
SR /TASC Number |
Vendor Name |
Description |
Patch Release |
SASS- 14566 / 305666 | Dell | Certified the following components for the dellN3048P Switch (System OID: .1.3.6.1.4.1.674.10895.3060): AggregatePort, Card, Fan, Interface, Memory, Processor, Port, PowerSupply, and VLAN. | 10.0.0.7 |
SASS- 14568 / 305631 | EXTREME | Certified the following components for the Summit X440G2-48p-10G4 Switch (System OID: .1.3.6.1.4.1.1916.2.220): Card, Fan, Interface, Port, PowerSupply, TemperatureSensor, and VLAN. | 10.0.0.7 |
SASS- 14511 / 305590 | HP | Certified the following components for the Aruba JL321A 2930M-48G Switch (System OID: .1.3.6.1.4.1.11.2.3.7.11.181.3): Fan, Interface, Port, Memory, Processor, PowerSupply, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS- 14556 / 305584 | Cisco | Certified the following components for the Cisco Identity Services Engine Host (System OID: .1.3.6.1.4.1.9.1.2786): File, Interface, Memory, Processor, MemoryGroup, and ProcessorGroup. | 10.0.0.7 |
SASS- 14539 / 305580 | Aruba | Certified the following components for the MM-HW-10K Wireless Controller (System OID: .1.3.6.1.4.1.14823.1.1.55): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, and VLAN. | 10.0.0.7 |
SASS- 14621 / 305579 | HP | Certified the following components for the Aruba JL660A 6300M 24SR5 CL6 PoE 4SFP56 Switch (System OID:.1.3.6.1.4.1.47196.4.1.1.1.102): Filesystem, Interface, Memory, Port, and Processor. | 10.0.0.7 |
SASS- 14538 / 305578 | Cisco | Certified the following components for the SG350-52P Switch (System OID:.1.3.6.1.4.1.9.6.1.95.52.5): Fan, Interface, Port, Processor, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS- 14515 / 305577 | Cisco | Certified the following components for the SG350-28 Switch (System OID:.1.3.6.1.4.1.9.6.1.95.28.1): Interface, Port, Processor, and VLAN. | 10.0.0.7 |
SASS- 14572 / 305576 | Cisco | Certified the following components for the C1000 StackSwitchSystem (System OID:.1.3.6.1.4.1.9.1.2959): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, VLAN, and SSSChassis. | 10.0.0.7 |
SASS- 14509 / 305575 | Cisco | Certified the following components for the Nexus9236C Switch (System OID:.1.3.6.1.4.1.9.12.3.1.3.1746): Card, Fan, Interface, Port, Memory, Processor, PowerSupply, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS- 14690 / 305566 | Cisco | Certified the following components for the ciscoFpr2140td Firewall (System OID:.1.3.6.1.4.1.9.1.2407): Interface, Processor, and Memory. | 10.0.0.7 |
SASS- 14680 / 305565 | Fortinet | Certified the following components for the FGT800C Firewall (System OID:.1.3.6.1.4.1.12356.101.1.8003): Disk, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VoltageSensor. | 10.0.0.7 |
SASS- 14525 / 305564 | Fortinet | Certified the following components for the FAZ-VM Firewall (System OID:.1.3.6.1.4.1.12356.103.3.64): Disk, Interface, Memory, and Processor. | 10.0.0.7 |
SASS- 14695 / 305563 | Cisco | Certified the following components for the cevChassisDSC9250IK9 Switch (System OID:.1.3.6.1.4.1.9.12.3.1.3.1326): Card, Fan, FibreChannelSwitchPort, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VLAN. | 10.0.0.7 |
SASS- 14686 / 305562 | Cisco | Certified the following components for the cevChassisN9KC9364CGX Switch (System OID:.1.3.6.1.4.1.9.12.3.1.3.2272): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VLAN. | 10.0.0.7 |
SASS- 14678 / 305559 | HP | Certified the following components for the HP2920-48G-PoE+(J9729A) Switch (System OID:.1.3.6.1.4.1.11.2.3.7.11.155): Fan, Interface, Memory, Processor, Port, PowerSupply, Temperature Sensor, and VLAN. | 10.0.0.7 |
SASS- 14673 / 305558 | HP | Certified the following components for the HP-E3800-24G-PoE+-2SFP+(J9573A) Switch (System OID:.1.3.6.1.4.1.11.2.3.7.11.119): Fan, Interface, Memory, Processor, Port, PowerSupply, Temperature Sensor, and VLAN. | 10.0.0.7 |
SASS- 14671 / 305548 | Cisco | Certified the following components for the Catalyst 3850-48U Switch (System OID:.1.3.6.1.4.1.9.1.1768): Aggregateport, Card, CardRedundandancygroup, Fan, Interface, Memory, Port, Powersupply, Processor, TemparatureSensor, and VLAN. | 10.0.0.7 |
SASS- 14669 / 305539 | A10 Networks | Certified the following components for the Thunder Series 3040S Router (System OID:.1.3.6.1.4.1.22610.1.3.35): Card, Fan, Interface, Memory, Powersupply, Processor, TemparatureSensor, Voltage Sensor, and Vlan. | 10.0.0.7 |
SASS- 14667 / 305524 | Riverbed | Certified the following components for the SteelFusion 2000 Host (System OID:.1.3.6.1.4.1.17163.1.100): FileSystem, Interface, Memory, MemoryGroup, Processor, and ProcessorGroup. | 10.0.0.7 |
SASS- 14665 / 305523 | Riverbed | Certified the following components for the SteelFusion 3000 Host (System OID:.1.3.6.1.4.1.17163.1.200): FileSystem, Interface, Memory, MemoryGroup, Processor, and ProcessorGroup. | 10.0.0.7 |
SASS- 14663 / 305517 | Cisco | Certified the following components for the ciscoISR4321B Router (System OID:.1.3.6.1.4.1.9.1.2339): Card, Fan, Interface, Memory, Port, Powersupply, Processor, TemparatureSensor, VoltageSensor, and Vlan. | 10.0.0.7 |
SASS- 14554 / 305516 | Arista | Certified the following components for the DCS-7280CR2K-60 Switch (System OID:.1.3.6.1.4.1.30065.1.3011.7280.2727.2.202.60): Interface, Memory, Port, Processor, and Vlan. | 10.0.0.7 |
SASS- 14551 / 305495 | Cisco | Certified the following components for the cevChassisN9KC93108TCFX Switch (System OID:.1.3.6.1.4.1.9.12.3.1.3.1893): Card, Fan, Memory, Port, PowerSupply, Processor, TemparatureSenor, and Vlan. | 10.0.0.7 |
SASS- 14661 / 305494 | Cisco | Certified the following components for the N9K-C93216TC-FX2 Switch (System OID:.1.3.6.1.4.1.9.12.3.1.3.2238): Card, Fan, Memory, Port, PowerSupply, Processor, TemparatureSenor, and Vlan. | 10.0.0.7 |
SASS- 14535 / 305491 | Fortinet | Certified the following components for the FortiSandbox404E Router (System OID:.1.3.6.1.4.1.12356.113.100.404): Interface, Memory, and Processor. | 10.0.0.7 |
SASS- 14520 / 305487 | Cisco | Certified the following components for the Secure Network Server 3615 Host (System OID:.1.3.6.1.4.1.9.1.2784): FileSystem, Interface, Memory, MemoryGroup, Port, Processor, ProcessorGroup, and TemparatureSensor. | 10.0.0.7 |
SASS- 14518 / 305484 | Pan | Certified the following components for the M-600 Router (System OID: .1.3.6.1.4.1.25461.2.3.39): Disk, Interface, Memory, and Processor. | 10.0.0.7 |
SASS- 14522 / 305481 | Aruba | Certified the following components for the Aruba-mm-hw-5K Switch (System OID: .1.3.6.1.4.1.14823.1.1.54): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, and Vlan. | 10.0.0.7 |
SASS- 14574 / 305472 | Cisco | Certified the following components for the Catalyst 9606R stand-alone Switch (System OID:.1.3.6.1.4.1.9.1.2648): Card, CardRedundancyGroup, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS-14657 / 305471 | Cisco | Certified the following components for the Catalyst 9606R virtual stack Switch (System OID: .1.3.6.1.4.1.9.1.2871): Card, CardRedundancyGroup, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS- 14652 / 305459 | Fortinet | Certified the following components for the FGT_3800D Firewall (System OID: .1.3.6.1.4.1.12356.101.1.38001): Disk, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VoltageSensor. | 10.0.0.7 |
SASS- 14648 / 305458 | Cisco | Certified the following components for the C9300L-48P-4X Switch (System OID: .1.3.6.1.4.1.9.1.2804): AggregatePort, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, VoltageSensor, and VLAN. | 10.0.0.7 |
SASS- 14646 / 305456 | Fortinet | Certified the following components for the FGT_3601E Firewall (System OID: .1.3.6.1.4.1.12356.101.1.36011): Disk, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VoltageSensor. | 10.0.0.7 |
SASS- 14560 / 305440 | Dell | Certified the following components for the S3148P Switch (System OID: .1.3.6.1.4.1.6027.1.3.24): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, TemperatureSensor, and VLAN. | 10.0.0.7 |
SASS- 14638 / 305428 | Silverpeak | Certified the following components for the NX3700 Bridge (System OID: .1.3.6.1.4.1.23867.1.2.11): Interface and Port. | 10.0.0.7 |
SASS- 14631 / 305427 | Dell | Certified the following components for the w-7005 WirelessController (System OID: .1.3.6.1.4.1.674.10895.5043): Card, Fan, Interface, Memory, Port, PowerSupply, Processor, and VLAN. | 10.0.0.7 |
SASS- 14516 / 305485 | Infoblox | Certified the following components for the IB-1415 Host (System OID: .1.3.6.1.4.1.7779.1.1503): Fan, FileSystem, Interface, Memory, MemoryGroup, PowerSupply, Processor, and ProcessorGroup. | 10.0.0.7 |