The components of a Blade Enclosure Manager that are monitored by IP Performance Manager are:
-
Power Supply — IP Performance Manager performs performance analysis on the PowerSupply object. Each power supply unit of the Blade Enclosure Manager is monitored and represented in the topology. A BladeEnclosureManager has a ComposedOf relationship with PowerSupply and conversely, PowerSupply has a PartOf relationship with BladeEnclosureManager.
-
Voltage Sensor — IP Performance Manager performs performance analysis on the following VoltageSensor objects for:
-
Power Supply Unit
-
Blade Server motherboard
-
-
Temperature Sensor — IP Performance Manager performs performance analysis on the following TemperatureSensor objects for:
-
IO module—Sensors present in the Fabric Extender.
-
Fan—Sensors for fan present in the chassis.
-
Motherboard Temperature counters for:
-
Motherboard Front Temperature
-
Motherboard Rear Temperature
-
Motherboard Rear Temperature Left
-
Motherboard Rear Temperature Right
-
-
Power supply in the chassis
-
-
Fan—IP Performance Manager performs performance analysis of the Fan. Each Fan unit of the BladeEnclosureManager is monitored and represented in the topology. The relationships of a BladeEnclosureManager with fan are:
-
ComposedOf relationship with Fan
-
Conversely, PartOf relationship with BladeEnclosureManager
All the thresholds settings are configured in the Polling and Thresholds console.
-