The following existing device issues have been discovered with other releases. In most cases, a resolution is included to address the issue.
-
Huawei devices do not support FTP or Telnet/SSH access from the same account. FTP access is hardcoded in the driver. For FTP configuration to work an FTP login emcftp with password emctester must exist.
-
For S2326TP-SI, S2326TP-PWR-EI, S3352P-PWR-EI, S5324TP-PWR-SI, and S5352C-PWR-SI models, configuration files are saved in zipped format. These configurations cannot be viewed in the user interface, but backup and restore operation can be performed.
-
Configuration pull and push:
-
Configuration pull and push is done using FTP for devices that support binary(.zip) configurations.
-
Configuration pull and push is done using Terminal for devices that support text (.cfg) configurations.
-
Configuration pull and push is done using FTP for devices that support both binary(.zip) and text(.cfg) configurations.
-
-
Serial number and physical hardware are not available using terminal.
-
Memory, file system information, and interfaces are not supported using SNMP.