In a storage array if a Disk fails, then Disk Rebuild starts on the Spare Disk.
Let the primary Disk be 0_0_1 and the Spare Disk be 0_0_24.
Workflow
-
When Disk 0_0_1 fails, then rebuild on the spare Disk 0_0_24 begins.
-
The failed Disk 0_0_1 is fixed and replaced before the completion of rebuild on the Spare Disk 0_0_24. The rebuild on Spare Disk 0_0_24 continues till rebuild is complete.
-
Notifications statuses:
-
DiskFault event and Down problem for Disk 0_0_1 are cleared.
-
DiskRebuildEvent and DiskRebuild are generated for Spare Disk 0_0_24 and remain till rebuild is complete.
-
-
-
Disk Rebuild on Disk 0_0_1 starts only after the completion of Disk Rebuild on Spare Disk 0_0_24.
-
The notifications DiskRebuildEvent and DiskRebuild are generated for Disk 0_0_1.
-
When Disk Rebuild on Disk 0_0_1 is complete, all notifications are cleared.