This section illustrates the DCF upgradation procedure in unattended (Silent) mode that is upgradation without user input.
Procedure
- When DCF base install location is /opt/DCF, type the setup command syntax:./vsa_dcf-10.1.9.0-3.bin -i silent and press Enter.
- If the base install location is different from /opt/DCF, specify the location of the product suite to be upgraded in properties file.
For example, specify the directory as:
USER_INSTALL_DIR=/opt/DCF1 in “dcf-10.1.9.0-3-silent-installer.properties” .
- To create installer.properties file, execute the command:
echo "USER_INSTALL_DIR=<DCF_Install_DIRECTORY>" > dcf-10.1.9.0-3-silent-installer.properties
- Provide the path to dcf-10.1.9.0-3-silent-installer.properties file.
Note: If it is not present in the DCF binary location, execute the command:
Product Name:
DCF
Install Folder:
/opt/DCF
./vsa_dcf-10.1.9.0-3.bin -i silent -f dcf-10.1.9.0-3-silent-installer.properties
Note: Ensure to update the
dcf-10.1.9.0-3-silent-installer.properties file with DCF base directory
<DCF_Install_DIRECTORY> correctly. Else a fresh installation will take place at the new location causing two DCF instances.