| VMware Telco Cloud Infrastructure 2.0 | 14 JAN 2021 Check for additions and updates to these release notes. |
| VMware Telco Cloud Infrastructure 2.0 | 14 JAN 2021 Check for additions and updates to these release notes. |
Carrier-Grade Resilient Networking
VMware NSX-T Data Center 3.1 introduces the following new features for virtualized networking and security for private, public, and multi-clouds.
Cloud-scale Networking: Federation enhancements and Enhanced Multicast capabilities
Intrinsic Security: Distributed IPS and FQDN-based Enhancements
Lifecycle and monitoring: NSX-T support with vSphere Lifecycle Manager (vLCM), simplified installation, enhanced monitoring, search and filtering.
For more information about these features, see the VMware NSX-T Data Center 3.1 Release Notes.
Multi-Tenancy Management
VMware Cloud Director 10.2 introduces the following new features and enhancements:
NSX-T Advanced Functional Parity: NSX Advanced Load Balancer (Avi), Distributed Firewall, VRF-lite, Cross VDC networking, IPv6, Dual stack (IPv4/IPv6) on the same network, SLAAC, DHCPv6, CVDS (vSphere 7.0/NSX-T 3.0), and L2VPN – API only.
VMware Cloud Director Virtual Appliance Enhancements: Validation of user inputs during the initial deployment. Simplified cell restore with streamlined standby cell creation.
Storage Enhancements: Disk-level IOPS control for providers and tenants; Shared disks
UI Enhancements: Quick Search, Advisories, and Certificate Management
For more information about these features and enhancements, see the VMware Cloud Director 10.2 Release Notes.
Workload Compute & Storage Performance
VMware vSphere 7.0 Update 1 introduces the following new features and enhancements:
Enhanced vSphere Lifecycle Manager hardware compatibility pre-checks for vSAN environments
Increased number of vSphere Lifecycle Manager concurrent operations on clusters
vSphere Lifecycle Manager support for coordinated updates between availability zones
Virtual hardware version 18
Increased resource maximums for virtual machines and performance enhancements
For more information about these features and enhancements, see the VMware vSphere 7.0 Update 1 Release Notes.
VMware vSAN 7.0 Update 1 introduces the following new features and enhancements:
HCI Mesh: HCI Mesh is a software-based approach for disaggregation of compute and storage resources in vSAN. It brings together multiple independent vSAN clusters by enabling cross-cluster utilization of remote datastore capacity within vCenter Server. HCI Mesh enables efficient utilization and consumption of data center resources and provides simple storage management at scale.
vSAN File Service Enhancements: Native vSAN File Service includes support for SMB file shares. Support for Microsoft Active Directory, Kerberos authentication, and scalability improvements also are available.
Compression-only vSAN: You can enable compression independent of deduplication, thereby providing the storage efficiency option for workloads that cannot leverage deduplication. With compression-only vSAN, a failed capacity device does not impact the entire disk group.
vSAN Data-in-Transit Encryption: Enables secure over-the-wire encryption of data traffic between nodes in a vSAN cluster. vSAN data-in-transit encryption is a cluster-wide feature. It can be enabled independently or along with the vSAN data-at-rest encryption. Traffic encryption uses the same FIPS-2 validated cryptographic module as the existing encryption features. It does not require a KMS server.
Enhanced Data Durability During Maintenance Mode: Protects the integrity of data when a host is in maintenance mode with the Ensure Accessibility option. All incremental writes to the host in maintenance are now redirected to another host, if it is available. This feature benefits VMs configured with PFTT=1 and also provides an alternative to PFTT=2 to ensure data integrity during maintenance operations.
For more information about these features, see the VMware vSAN 7.0 Update 1 Release Notes.
VMware ESXi 7.0 U1. See the VMware ESXi 7.0 Update 1 Release Notes.
VMware vSphere Replication 8.3.1. See the VMware vSphere Replication 8.3.1 Release Notes.
VMware vRealize Orchestrator Appliance 8.2. See the VMware vRealize Orchestrator 8.2 Release Notes.
VMware NSX-T Data Center Advanced Edition 3.1. See the VMware NSX-T Data Center 3.1 Release Notes.
VMware vRealize Operations Manager 8.2 Advanced Edition. See the VMware vRealize Operations Manager 8.2 Release Notes.
VMware vRealize Log Insight 8.2. See the VMware vRealize Log Insight 8.2 Release Notes.
VMware vSAN 7.0 U1 Standard Edition. See the VMware vSAN 7.0 Update 1 Release Notes. Binaries are distributed as part of the VMware vSphere download. Requires a separate activation license key that is included as part of Telco Cloud Infrastructure Cloud Director Edition.
VMware Cloud Director 10.2. See the VMware Cloud Director 10.2 Release Notes.
Mandatory Add-On Components
Note: Additional license is required.
VMware vCenter Server 7.0 U1a. See the VMware vCenter Server 7.0 Update 1a Release Notes.
Optional Add-On Components
Note: Additional license is required.
VMware Site Recovery Manager 8.3.1. See the VMware Site Recovery Manager 8.3.1 Release Notes.
VMware vRealize Network Insight 6.0. See the VMware vRealize Network Insight 6.0 Release Notes.
New VMware vCenter Server 7.0 Update 3j. See the VMware vCenter Server 7.0 Update 3j Release Notes.
New VMware ESXi 7.0 Update 3i. See the VMware ESXi 7.0 Update 3i Release Notes.
New VMware Cloud Director 10.2.2.3. See the VMware Cloud Director 10.2.2.3 Release Notes.
VMware vCenter Server 7.0 Update 2d. See the VMware vCenter Server 7.0 Update 2d Release Notes.
VMware ESXi 7.0 Update 2d. See the VMware ESXi 7.0 Update 2d Release Notes.
VMware NSX-T Data Center 3.1.2. See the VMware NSX-T Data Center 3.1.2 Release Notes.
VMware ESXi 7.0 U1b. See the VMware ESXi 7.0 Update 1b Release Notes.
Dynamically Changing the Lcore Assignment Value from the Transport Node Profile May Cause ESXi Server to PSOD
This issue is fixed in VMware NSX-T Data Center 3.1.2.
Unable to Power ON the Cloud Director VMs That are Connected with SR-IOV Network
This issue is fixed in VMware Cloud Director 10.2.
TraceFlow From One VM to Another VM is Not Working in Guest Inter-VLAN Routing in NSX-T Data Center
This issue is fixed in VMware NSX-T Data Center 3.1.
Objects of Cloud Director Provider UI are Not Visible When Using Invalid Certificates for Configuring Multisite Cloud Director Association
This issue is fixed in VMware Cloud Director 10.2.
Cloud Director UI Gets Stuck When Creating vApp Using Extra Configuration Parameter in OVA/OVF Template
This issue is fixed in VMware Cloud Director 10.2.
Tunnels on the Edge and Host Nodes Go Down in ESXi After Modifying the Lcore Assignments to the NUMA Nodes
When modifying the number of lcores assigned to the NUMA nodes in the transport node profile, the tunnels go down on the respective edge and host nodes.
Workaround: Follow the instructions in the KB article 83737.
Bootstrap Patch Termination Error Occurs When Upgrading vRealize Orchestrator from Version 8.1 to 8.2
When you upgrade vRealize Orchestrator from version 8.1 to 8.2, the following error occurs:
Update bootstrap patch was terminated.
Workaround: Deploy vRealize Orchestrator 8.2 using the Greenfield method instead of upgrade and import the vRealize Orchestrator objects such as workflows and packages from vRealize Orchestrator 8.1. For more information, see Managing Packages in the vRealize Orchestrator documentation.
Unable to Launch VM Web Console Using the Launch Web Console Option in VMware Cloud Director
The VM Web Console is not launching when using the Launch Web Console option in VMware Cloud Director.
Workaround: Access the VM Console using the Launch Remote Console option from the VMware Cloud Director UI or from the corresponding vCenter Server.
Network Creation Failed During the NSX-T Node Failover
The creation of a new network fails in the VMware Cloud Director UI when the NSX-T node failover is in progress.
Workaround: Wait until the NSX-T node failover completes and then create the network from the Cloud Director UI.
IPv4 North-South Communication Breaks When Adding IPv6 NIC Followed by IPv4
If you add IPv6 NIC first and IPv4 NIC later to a virtual machine using the VMware Cloud Director UI, the IPv4 north-south communication breaks.
Workaround: Always add IPv4 NIC first followed by IPv6 NIC to the VM.
Cannot Merge Provider VDCs Backed by NSX-T Data Center
When you merge two Provider Virtual Data Centers (VDCs) that are backed by NSX-T Data Center, the following error occurs: Cannot merge Provider VDCs. Found NSX-T backed Provider VDC
Workaround: None
| Date |
Change |
|---|---|
| 7 FEB 2023 |
The following component versions are added to the Validated Patches section:
|
| 04 OCT 2021 |
The following component versions are added to the Validated Patches section:
|
| 7 JUN 2021 |
|
For additional support resources, see the VMware Telco Cloud Infrastructure documentation page.