Prepare the physical servers for the ESXi installation.
Prerequisites
-
The servers must be physically installed in the rack.
-
Ethernet ports must be connected to the physical switches in a redundant configuration.
-
Each physical server must have two dual-port Ethernet controllers, with a total of four Ethernet ports.
-
Physical CPU virtualization must be enabled from the BIOS on all physical servers.
The following table includes the network configuration details for the ESXi host:
Host Network Controller |
Ethernet Port |
Physical Switch |
---|---|---|
1 |
Port 0 |
1 |
1 |
Port 1 |
2 |
2 |
Port 0 |
1 |
2 |
Port 1 |
2 |
3 (required for resource hosts) |
Port 0 |
1 |
3 (required for resource hosts) |
Port 1 |
2 |
Procedure
- Mount the servers in a rack.
- Wire the ESXi hosts to the two physical switches and power supplies.
- Connect all the physical server Ethernet ports to the two physical switches in a redundant network configuration.
- On each physical server, connect and configure the embedded management controllers, such as Intelligent Platform Management Interface (IPMI).