To enable connectivity and network isolation to the virtual infrastructure, configure the physical switches for the Management, Edge, and Compute Clusters.

Procedure

  1. Configure the VLAN IDs on the two physical switches.
    Note:

    The following VLAN IDs are only indicative and used only to describe the deployment steps. Replace them with VLAN IDs that fit the network design of your environment.

    VLAN

    ID

    Function

    Port Group

    Network Type

    Management Cluster

    100

    ESXi Management

    ESXi Management

    Infrastructure

    200

    vSphere vMotion

    vMotion Network

    Infrastructure

    300

    vSAN Storage

    vSAN Network

    Infrastructure

    400

    NFS

    NFS Network

    Infrastructure

    10

    VM Management

    VM Management Network

    Tenant

    20

    vCenter HA

    vCenter HA Network

    Tenant

    30

    External

    External Network

    Tenant

    40

    Backup

    Backup Network

    Tenant

    Edge Cluster

    100

    ESXi Management

    ESXi Management

    Infrastructure

    200

    vSphere vMotion

    vMotion Network

    Infrastructure

    300

    vSAN Storage

    vSAN Network

    Infrastructure

    400

    NFS

    NFS Network

    Infrastructure

    10

    VM Management

    VM Management Network

    Tenant

    Trunk (0-4094)

    External

    External Network

    Tenant

    Trunk (0-4094)

    Overlay

    Overlay Network

    Tenant

    Compute Cluster

    100

    ESXi Management

    ESXi Management

    Infrastructure

    200

    vSphere vMotion

    vMotion Network

    Infrastructure

    300

    vSAN Storage

    vSAN Network

    Infrastructure

    400

    NFS

    NFS Network

    Infrastructure

    10

    VM Management

    VM Management Network

    Infrastructure

    <N>

    Note: N indicates any VLAN ID.

    Enhanced Data Path

    Enhanced Data Path Network

    VDS (E) VLAN

    80

    Enhanced Data Path (TEP)

    Enhanced Overlay Network

    VDS (E) Overlay

    <N>

    NSX Standard

    Standard VLAN Network

    VDS (S) VLAN

    70

    NSX Standard (TEP)

    Overlay Network

    VDS (S) Overlay

    <N>

    SR-IOV

    SR-IOV Network

    Tenant

  2. Configure ToR switches to terminate the vSphere vMotion and vSAN networks.
  3. Configure the MTU size to a jumbo frame value on all assigned network ports.

    MTU jumbo frame values vary by manufacturer. For example, to configure the MTU size of the Guest OS to 8900 bytes, you must configure the MTU size of the Physical switch to 9000 bytes.