This section provides information, how to handel the Java Exception when VCO discovery fails.

If the VCO discovery fails with Java Exception and below message appears in discovery collector logs:
WARNING – [2019-06-12 13:44:07 IST] – HttpRequestGroup::executeRequest(): Error running command 
@{protocol}://@{host}:@{PORT}/portal/rest/enterprise/getEnterpriseEdges on host 10.148.87.69 for requests group 
RETRIEVE ENT EDGES TO FORM TUNNEL org.apache.http.conn.ConnectTimeoutException: 
Connect to 10.148.87.69:443 [/10.148.87.69] failed: Read timed out

Then, need to increase the timeout "connection-timeout="120s" in "<DCF-InstallLocation>/Collecting/Stream-Collector/<Collector-Instance>/conf/requests/discovery-retriever.xml".