To configure a Standby Adapter Platform:
- Disable topology synchronization in the Standby location so that the Standby Adapter Platform does not synchronize with the underlying Domain Managers while the Domain Managers are still starting up.
- In the installation area where the Standby Adapter Platform is running, Go to the BASEDIR/smarts/bin directory and open the bootend.conf file:
./sm_edit conf/icoi/bootend.conf
- Change the value of suspendTopologyManager to TRUE.
Note: The value of suspendTopologyManager is FALSE by default.
- Save the file and exit.
- Install the service for the Standby Adapter Platform as outlined in “Configure Active Adapter Platform” on page 27.
- Start the service in “Start the services for SAM, Adapter Platform, and BIM” on page 27.
At this point, additional manual configuration is no longer required.
-
Later, after you modify the failover.conf file and run the sm_configureFailover.pl script, the script automatically creates all necessary subscriptions to the counterparts.
-
Later, when you run the manual backup, the Failover Manager adds the underlying source Domain Managers from the Active location to the Standby location.
-