You can configure the Virtual IMS Collector to collect data from various data sources. vIMS provides the scalable deployment of IP Multimedia Subsystem (IMS) in virtualized and cloud environments for voice, video, and messaging services. Also, vIMS converges services supplied by different types of networks such as fixed, mobile, and Internet. It allows the creation and deployment of IP-based multimedia services in the 5G networks.
Procedure
- Go to http://Telcocloud serviceassurance-ui-IP.
A typical URL for logging in to the user interface from the same system on which VMware Telco Cloud Service Assurance is installed is, http://10.x.x.x.
- Enter the user name and password.
- Click Next.
- Navigate to the Administration > Configuration > Collectors and Connectors tab.
- In Collector section, click Add.
The Collector Selection page is displayed.
- Select the viptela-sdwan data collector.
viptela-sdwan Configuration page appears.
Note: For more information on configuration from Domain Manager side, see vIMS Configuration. - To configure the collector, enter the parameters as mentioned in the following table:
Input Parameter Description Default Value Name of the collector Collector instance name. NA Data center The location of vIMS clearwater collector data. Core Configure an Clearwater Sprout Node Hostname or IP address of the Clearwater Sprout Node. The Sprout node IP address or the FQDN in the Clearwater deployment. NA SNMP Port SNMP port number to poll. 161
Select the SNMP Protocol from the list. SNMP protocol type used for polling. udp
SNMP Community Value SNMP community string information of the Sprout node.
ex: public, clear water.
public
Select SNMP Version. SNMP version of the Sprout SNMP agent. v2c
Deployment ID of the vIMS Deployment ID of vIMS. Bono-DeploymentID
Orchestrator Hostname or IP address Orchestrator (For example, Cloudify) HostName or IP address. NA Timeout SNMP polling timeout period in seconds. 30
Configure a Clearwater Bono Node Hostname or IP address of the Clearwater Bono
Node.Bono
node IP address or FQDN in the Clearwater deployment.NA SNMP Port SNMP port number to poll. 161
Select SNMP Protocol from the list. SNMP protocol type used for polling. udp
SNMP Community Value SNMP community string information of
ex: public, clear water.Bono
node.public
Select SNMP Version. SNMP version of Bono
SNMP agent.v2c
Deployment Id of the vIMS Deployment ID of vIMS. Sprout-DeploymentID
Orchestrator Hostname or IP address Orchestrator (For example, Cloudify) HostName or IP address. NA Timeout SNMP polling timeout period in seconds. 30 The Sprout data Polling Range (in seconds): 60–3600. Time in seconds for periodic polling of Sprout nodes. The value must be between 60 and 3600. 300 Bono
data Polling Range (in seconds): 60–3600Time in seconds for periodic polling Bono
nodes. The value must be between 60 and 3600.300 - Click Create Collector.