vRealize Automation requires several Windows virtual machines to act as IaaS components in a distributed configuration. These redundant components provide high availability for the vRealize Automation infrastructure features.

About this task

To facilitate cloning, this design uses the vra7-proxy-agent-template image customization specification template and the windows-2012r2-64 VM template. Two virtual machines that run on Windows will be required to install vRealize Automation Proxy Agents in Region B. Repeat this procedure twice by using the information in the following table to create two VMs.

Name for Virtual Machines

NetBIOS name

vCenter Folder

IP

vCPU number

Memory Size

Image Customization Specification Template

Network

vra01ias51.lax01.rainpole.local

vra01ias51

vRA01IAS

192.168.32.52

2

4 GB

vra7-proxy-agent-template

vxw-dvs-xxxx-Mgmt-RegionB01-VXLAN

vra01ias52.lax01.rainpole.local

vra01ias52

vRA01IAS

192.168.32.53

2

4 GB

vra7-proxy-agent-template

vxw-dvs-xxxx-Mgmt-RegionB01-VXLAN

Prerequisites

Verify that you have created the Windows 2012 R2 template VM windows2012r2-template. See Virtual Machine Template Specifications.

Procedure

  1. Log in to the vSphere Data Protection Configure Utility.
    1. Open a Web browser and go to https://mgmt01vdp51.lax01.rainpole.local:8543/vdp-configure.
    2. Log in using the following credentials.

      Setting

      Value

      User name

      root

      Password

      vdp_appliance_root_password

  2. In the Navigator pane, select Global Inventory Lists > vCenter Servers. Click the mgmt01vc51.lax01.rainpole.local instance.
  3. Select VM Templates in Folders, and from the VM Templates in Folders pane, right-click the IaaS windows template win2012r2-template and select New VM from this Template.
  4. On the Select a name and folder page of the Deploy From Template wizard, specify a name and location for the virtual machine. 
    1. Enter vra01ias51.lax01.rainpole.local in the Enter a name for the virtual machine  text box.
    2. In the Select a location for the virtual machine pane, select the vRA01IAS folder in the LAX01 datacenter under mgmt01vc51.lax01.rainpole.local, and click Next
  5. On the Select a compute resource page, select LAX01-Mgmt01 and click Next.
  6. On the Select storage page, select the datastore on which to create the virtual machine's disks.
    1. Select vSAN Default Storage Policy from the VM Storage Policy drop-down menu.
    2. Select the LAX01A-VSAN01-MGMT01 vSAN datastore from the datastore table and click Next.




  7. On the Select Clone options page, select the Customize the operating system check box, and click Next.
  8. On the Customize guest OS page, select the vra7-proxy-agent-template from the table, and click Next
  9. On the User Settings page, enter the following values, and click Next.

    Setting

    Value

    NetBIOS name

    vra01ias51

    IPv4 address

    192.168.32.52

    IPv4 subnet mask

    255.255.255.0

  10. On the Ready to Complete page, review your settings and click Finish.

    When the deployment of the virtual machine completes, you can customize the virtual machine.

  11. In the Navigator, select VMs and Templates.
  12. Right-click the vra01ias51.lax01.rainpole.local virtual machine and select Edit Settings.
  13. Click Virtual Hardware and configure the settings for CPU, Memory, and the Network adapter 1.
    1. Select 2 from the CPU drop-down menu.
    2. Set the Memory settings to 4096 MB.
    3. Expand Network adapter 1 and select vxw-dvs-xxxx-Mgmt-RegionB01-VXLAN from the drop-down menu and click OK.




  14. Right-click the virtual machine vra01ias51.lax01.rainpole.local, and select Power >  Power on.
  15. From the Virtual Machine Console, verify that vra01ias51.lax01.rainpole.local reboots, and uses the configuration settings that you specified.

    After the Windows customization process completes, a clean desktop appears.

  16. Log in to the Windows operating system and perform final verification and customization.
    1. Verify that the IP address, computer name, and domain are correct.
    2. Verify vRealize Automation service account svc-vra@rainpole.local to the Local Administrators Group.
  17. Repeat this procedure to deploy and configure the remaining virtual machine.