Configure the NSX Manager for the management cluster and the NSX Manager for the shared edge and compute cluster to send audit logs and system events to vRealize Log Insight in Region B. 

Procedure

  1. On the Windows host that has access to the data center, log in to the NSX Manager Web interface.
    1. Open a Web browser and go to following URL. 

      NSX Manager

      URL

      NSX Manager for the management cluster

      https://mgmt01nsxm51.lax01.rainpole.local

      NSX Manager for the shared compute and edge cluster

      https://comp01nsxm51.lax01.rainpole.local

    2. Log in using the following credentials.

      Setting

      Value

      User name

       admin

      Password

       nsx_manager_admin_password

  2. On the main page of the appliance user interface, click Manage Appliance Settings.
  3. Under Settings, click General, and in the Syslog Server pane, click Edit.
  4. In the Syslog Server dialog box, configure vRealize Log Insight as a syslog server by specifying the following settings and click OK.

    Syslog Server Setting

    Value

    Syslog Server

    vrli-cluster-51.lax01.rainpole.local

    Port

    514

    Protocol

    UDP

  5. Repeat the steps for the other NSX Manager.