This VMware Validated Design requires that the following VLAN IDs and IP subnets be allocated for the traffic types in the SDDC.

VLANs and IP Subnets in Region A

According to the VMware Validated Design, you have the following VLANs and IP subnets in Region A.

Table 1. VLAN and IP Subnet Configuration in Region A

Pod in Region A

VLAN Function

VLAN ID

Subnet

Gateway

Management Pod

ESXi Management

1611

172.16.11.0/24

172.16.11.253

vSphere vMotion

1612

172.16.12.0/24

172.16.12.253 

vSAN

1613

172.16.13.0/24

172.16.13.253

VXLAN (NSX VTEP)

1614

172.16.14.0/24

172.16.14.253

NFS

1615

172.16.15.0/24

172.16.15.253

  • vSphere Replication

  • vSphere Replication NFC

1616

172.16.16.0/24

172.16.16.253

Uplink01

2711

172.27.11.0/24

172.27.11.253

Uplink02

2712

172.27.12.0/24

172.27.12.253

External Management Connectivity

130

10.158.130.0/24

10.158.130.253

Shared Edge and Compute Pod

ESXi Management

1631

172.16.31.0/24

172.16.31.253

vSphere vMotion

1632

172.16.32.0/24

172.16.32.253

vSAN

1633

172.16.33.0/24

172.16.33.253

VXLAN (NSX VTEP)

1634

172.16.34.0/24

172.16.34.253

NFS

1625

172.16.25.0/24

172.16.25.253

Uplink01

1635

172.16.35.0/24

172.16.35.253

Uplink02

2713

172.27.13.0/24

172.27.13.253

External Tenant Connectivity

140

10.158.140.0/24

10.158.140.253

VLAN IDs and IP Subnets in Region B

If you expand your design to two regions later, you have the following VLANs and IP subnets in Region B.

Table 2. VLAN and IP Subnet Configuration in Region B 

Region B

VLAN Function

VLAN ID

Subnet

Gateway

Management Pod

ESXi Management

1711

172.17.11.0/24

172.17.11.253

vSphere vMotion

1712

172.17.12.0/24

172.17.12.253 

vSAN

1713

172.17.13.0/24

172.17.13.253

VXLAN (NSX VTEP)

1714

172.17.14.0/24

172.17.14.253

NFS

1715

172.17.15.0/24

172.17.15.253

  • vSphere Replication

  • vSphere Replication NFC

1716

172.17.16.0/24

172.17.16.253

Uplink01

2714

172.27.14.0/24

172.27.14.253

Uplink02

2715

172.27.15.0/24

172.27.15.253

External Management Connectivity

150

10.158.150.0/24

10.158.150.253

Shared Edge and Compute Pod

ESXi Management

1731

172.17.31.0/24

172.17.31.253

vSphere vMotion

1732

172.17.32.0/24

172.17.32.253

vSAN

1733

172.17.33.0/24

172.17.33.253

VXLAN (NSX VTEP)

1734

172.17.34.0/24

172.17.34.253

NFS

1725

172.17.25.0/24

172.17.25.253

Uplink01

1735

172.17.35.0/24

172.17.35.253

Uplink02

2721

172.27.21.0/24

172.27.21.253

External Tenant Connectivity

160

10.158.160.0/24

10.158.160.253

Note:

These VLAN IDs and IP subnets are examples. The actual implementation depends on your environment.