This VMware Validated Design requires that you allocate certain VLAN IDs and IP subnets for the traffic types in the consolidated SDDC.

According to the VMware Validated Design, you have the following VLANs and IP subnets for Consolidated SDDC.

Table 1. VLAN and IP Subnet Configuration for Consolidated SDDC

Pod in Consolidated SDDC

VLAN Function

VLAN ID

Subnet

Gateway

Consolidated Pod

ESXi Management

1631

172.16.31.0/24

172.16.31.253

Management Virtual Machines

1611

172.16.11.0/24

172.16.11.253

vSphere vMotion

1632

172.16.32.0/24

172.16.32.253

vSAN

1633

172.16.33.0/24

172.16.33.253

VXLAN (NSX VTEP)

1634

172.16.34.0/24

172.16.34.253

Secondary Storage

1625

172.16.25.0/24

172.16.25.253

Uplink01

1635

172.16.35.0/24

172.16.35.253

Uplink02

2713

172.27.13.0/24

172.27.13.253

External Tenant Connectivity

140

10.158.140.0/24

10.158.140.253