The shared edge and compute cluster uses a single vSphere Distributed Switch with the following configuration settings.

Table 1. Virtual Switch for the Shared Edge and Compute Cluster

vSphere Distributed Switch Name

Function

Network I/O Control

Number of Physical NIC Ports

MTU

sfo01-w01-vds01

  • ESXi Management

  • Network IP Storage (NFS)

  • vSphere vMotion

  • VXLAN Tunnel Endpoint (VTEP)

  • Uplinks (2) to enable ECMP

  • vSAN

  • External customer/tenant connectivity

Enabled

2

9000

Table 2. vDS-Comp01 Port Group Configuration Settings

Parameter

Setting

Failoverdetection

Link status only

Notify switches

Enabled

Failback

Yes

Failover order

Active uplinks: Uplink1, Uplink2

Network Switch Design for Shared Edge and Compute Hosts

This section expands on the logical network design by providing details on the physical NIC layout and physical network attributes.

Figure 1. Network Switch Design for Shared Edge and Compute Hosts




Table 3. Shared Edge and Compute Cluster Virtual Switches by Physical/Virtual NIC

vSphere Distributed Switch

vmnic

Function

sfo01-w01-vds01

0

Uplink

sfo01-w01-vds01

1

Uplink

Note:

The following VLANs are meant as samples. Your actual implementation depends on your environment.

Table 4. Shared Edge and Compute Cluster Virtual Switch Port Groups and VLANs

vSphere Distributed Switch

Port Group Name

Teaming Policy

Active Uplinks

VLAN ID

sfo01-w01-vds01

sfo01-w01-vds01-management

Route based on physical NIC load

1, 2

1631

sfo01-w01-vds01

sfo01-w01-vds01-vmotion

Route based on physical NIC load

1, 2

1632

sfo01-w01-vds01

sfo01-w01-vds01-vsan

Route based on physical NIC load

1, 2

1633

sfo01-w01-vds01

sfo01-w01-vds01-nfs

Route based on physical NIC load

1, 2

1615

sfo01-w01-vds01

Auto Generated (NSX VTEP)

Route based on SRC-ID

1, 2

1634

sfo01-w01-vds01

sfo01-w01-vds01-uplink01

Route based on originating virtual port

1

1635

sfo01-w01-vds01

sfo01-w01-vds01-uplink02

Route based on originating virtual port

2

2713

Table 5. Shared Edge and Compute Cluster VMkernel Adapter

vSphere Distributed Switch

Network Label

Connected Port Group

Enabled Services

MTU

sfo01-w01-vds01

Management

sfo01-w01-vds01-management

Management Traffic

1500 (Default)

sfo01-w01-vds01

vMotion

sfo01-w01-vds01-vmotion

vMotion Traffic

9000

sfo01-w01-vds01

VSAN

sfo01-w01-vds01-vsan

VSAN

9000

sfo01-w01-vds01

NFS

sfo01-w01-vds01-nfs

-

9000

sfo01-w01-vds01

VTEP

Auto Generated (NSX VTEP)

-

9000