After all the upgrade tasks for vSphere vCenter in Region A are completed, configure uplink01 and uplink02 in vSphere Distributed Switch to handle the traffic of the management applications in the SDDC.
About this task
Procedure
- Log in to the Management vCenter Server by using the vSphere Web Client.
- Open a Web browser and go to https://sfo01m01vc01.sfo01.rainpole.local/vsphere-client.
- Log in using the following credentials.
Setting
Value
User name
administrator@vsphere.local
Password
vsphere_admin_password
- Configure the uplinks for the sfo01-m01-vds01-uplink01 and sfo01-m01-vds01-uplink02 port groups.
- From the Home menu, click Networking.
- Expand the sfo01m01vc01.sfo01.rainpole.local sfo01-m01-vds01 tree.
- Under sfo01-m01-vds01 distributed switch, right click the sfo01-m01-vds01-uplink01 port group, and click Edit Settings.
- In the Edit Settings dialog box, click Teaming and failover.
- Select Load balancing as Route based on originating virtual port.
- In Failover order pane, move dvUplink2 to Unused uplinks and click OK.
- Under sfo01-m01-vds01 distributed switch, right click the sfo01-m01-vds01-uplink02 port group, and click Edit Settings.
- In the Edit Settings dialog box, select Teaming and failover.
- Select Load balancing as Route based on originating virtual port.
- In Failover order pane, move dvUplink1 to Unused uplinks and click OK.