Delete the virtual machines that are part of the external vRealize Orchestrator cluster from the inventory. vRealize Orchestrator has been migrated to an instance that is embedded in the vRealize Automation Appliance according to the objectives of this version of the validated design.

Procedure

  1. Log in to vCenter Server by using the vSphere Web Client.
    1. Open a Web browser and go to https://sfo01m01vc01.sfo01.rainpole.local/vsphere-client.
    2. Log in using the following credentials.

      Setting

      Value

      User name

      administrator@vsphere.local

      Password

      vsphere_admin_password

  2. In the Navigator, click VMs and Templates and expand the sfo01m01vc01.sfo01.rainpole.local > sfo01-m01dc tree.
  3. Click the sfo01-m01fd-vra folder and click the VMs > Virtual Machines tab.
  4. Select the vra01vro01a.rainpole.local and vra01vro01b.rainpole.local virtual machines and click the Shut Down Guest OS button.
  5. Select the two Orchestrator virtual machines again and select Actions > Remove from Inventory and click Yes to confirm.
    Note:

    You can clean up the virtual machines at a later time after verifying that the SDDC is in a working state after the upgrade.

  6. Clean up the Orchestrator database vROCluster on the external Microsoft SQL server.