Before you deploy the NSX Components of the Management Cluster in Region B, verify that your environment satisfies the requirements for this deployment.

IP Addresses and Host Names

Verify that static IP addresses and FQDNs for the management networks are available for the SDDC deployment.

Allocate static IP addresses and FQDNs for the NSX Manager, NSX Controller nodes, and components.

Table 1. Network Names for SDDC Components
NSX Manager Region B Network
NSX Manager lax01-m01-vds01-management
NSX Controllers lax01-m01-vds01-management
Table 2. IP Addresses and Host Names for the NSX Components in Region B
Role IP Address FQDN
NSX Manager 172.17.11.65 lax01m01nsx01.lax01.rainpole.local
Edge Services Gateway 01 172.27.14.2 lax01m01esg01.lax01.rainpole.local
172.27.15.3
192.168.10.50
Edge Services Gateway 02 172.27.14.3 lax01m01esg02.lax01.rainpole.local
172.27.15.2
192.168.10.51
Universal Distributed Logical Router 192.168.10.3 sfo01m01udlr01.sfo01.rainpole.local
192.168.32.1
Application Load Balancer 192.168.11.2 lax01m01lb01.lax01.rainpole.local
PSC Load Balancer 172.17.11.71 lax01psc01.lax01.rainpole.local
Subnet mask 255.255.255.0 -
DNS 172.17.11.5 -
172.17.11.4
Gateway 172.17.11.253 -
NTP servers
  • 172.17.11.251
  • 172.17.11.252
  • ntp.lax01.rainpole.local

Deployment Prerequisites

Verify that your environment satisfies the following prerequisites for the deployment of NSX Manager and Components.

Prerequisite Value
Storage
  • Virtual disk provisioning.
    • Thin
  • Required storage per NSX Manager:
    • Initial storage for the NSX Manager: 60 GB
  • Required storage per NSX Controller nodes and Components.
    • Storage requirement: 240 GB
Software Features
  • Verify that management vCenter Server is operational.
Installation Package
  • Download the .iso file for the NSX Manager.
License
  • Verify that you have obtained NSX license with a quantity that satisfies the requirements of this design.
Active Directory
  • Verify that you have a parent active directory with the SDDC user roles configured for the rainpole.local domain.
Certificate Authority
  • Configure the root Active Directory domain controller as a certificate authority for the environment.
  • Download the CertGenVVD tool and generate the signed certificate for the NSX Manager. See the VMware Validated Design Planning and Preparation documentation.