This VMware Validated Design requires that you allocate certain VLAN IDs and IP subnets for the traffic types in the SDDC.
To meet the requirements of this VMware Validated Design, you must have the following VLANs and IP subnets in ROBO.
Cluster |
VLAN Function |
VLAN ID |
Subnet |
Gateway |
---|---|---|---|---|
ROBO Cluster |
ESXi Management |
1811 |
172.18.11.0/24 |
172.18.11.253 |
vSphere vMotion |
1812 |
172.18.12.0/24 |
172.18.12.253 |
|
vSAN |
1813 |
172.18.13.0/24 |
172.18.13.253 |
|
VXLAN (NSX VTEP) |
1814 |
172.18.14.0/24 |
172.18.14.253 |
|
Secondary Storage |
1815 |
172.18.15.0/24 |
172.18.15.253 |
|
Uplink01 |
1816 |
172.18.16.0/24 |
172.18.16.253 |
|
Uplink02 |
1817 |
172.18.17.0/24 |
172.18.17.253 |
Note: