This VMware Validated Design requires that you allocate certain VLAN IDs and IP subnets for the traffic types in the SDDC.

To meet the requirements of this VMware Validated Design, you must have the following VLANs and IP subnets in ROBO.

Table 1. VLAN and IP Subnet Configuration in ROBO

Cluster

VLAN Function

VLAN ID

Subnet

Gateway

ROBO Cluster

ESXi Management

1811

172.18.11.0/24

172.18.11.253

vSphere vMotion

1812

172.18.12.0/24

172.18.12.253

vSAN

1813

172.18.13.0/24

172.18.13.253

VXLAN (NSX VTEP)

1814

172.18.14.0/24

172.18.14.253

Secondary Storage

1815

172.18.15.0/24

172.18.15.253

Uplink01

1816

172.18.16.0/24

172.18.16.253

Uplink02

1817

172.18.17.0/24

172.18.17.253

Note:

Use these VLAN IDs and IP subnets as examples. Configure the actual VLAN IDs and IP subnets according to your environment.