After you deploy the NSX-T Edge nodes and join them to the management plane, to connect the nodes to the workload domain, add them to the transport zones for uplink and overlay traffic, and configure the N-VDS switches on each edge node.
Procedure
- Log in to the user interface of NSX-T Manager.
- Open a Web browser and go to https://sfo01wnsx01.sfo01.rainpole.local.
- Log in by using the following credentials.
Setting |
Value |
User name |
admin |
Password |
compnsx_admin_password |
- On the main navigation bar, click System.
- In the navigation pane, select .
- Select the sfo01wesg01 edge node and click Configure NSX.
- Under Edit Transport Node - sfo01wesg01, click the General tab.
- Under Transport Zones, move the following transport zones to the Selected list and click Add.
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Transport Zones |
sfo01-w-uplink01(VLAN) |
sfo01-w-uplink01(VLAN) |
sfo01-w-uplink02(VLAN) |
sfo01-w-uplink02(VLAN) |
sfo01-w-overlay(Overlay) |
sfo01-w-overlay(Overlay) |
- Under Edit Transport Node - sfo01wesg01, click the N-VDS tab.
- Under New Node Switch, enter the following values.
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Edge Switch Name |
sfo01-w-nvds01 |
sfo01-w-nvds01 |
Uplink Profile |
sfo01-w-overlay-profile |
sfo01-w-overlay-profile |
IP Assignment |
Use Static IP List |
Use Static IP List |
Static IP List |
172.16.49.21 |
172.16.49.22 |
Gateway |
172.16.49.253 |
172.16.49.253 |
Subnet Mask |
255.255.255.0 |
255.255.255.0 |
Virtual NICs |
fp-eth0 |
uplink-1 |
fp-eth0 |
uplink-1 |
- Click Add N-VDS, enter the following values.
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Edge Switch Name |
sfo01-w-nvds01-uplink01 |
sfo01-w-nvds01-uplink01 |
Uplink Profile |
sfo01-w-uplink01-profile |
sfo01-w-uplink01-profile |
IP Assignment |
Greyed Out |
Greyed Out |
Virtual NICs |
fp-eth1 |
uplink-1 |
fp-eth1 |
uplink-1 |
- Click Add N-VDS, enter the following values, and click Save.
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Edge Switch Name |
sfo01-w-nvds01-uplink02 |
sfo01-w-nvds01-uplink02 |
Uplink Profile |
sfo01-w-uplink02-profile |
sfo01-w-uplink02-profile |
IP Assignment |
Greyed Out |
Greyed Out |
Virtual NICs |
fp-eth2 |
uplink-1 |
fp-eth2 |
uplink-1 |
- Repeat the step on sfo01wesg02.
Results
The edge transport nodes have the following configuration:
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Edge |
sfo01wesg01 |
sfo01wesg02 |
Management IP |
172.16.41.21 |
172.16.41.22 |
Configuration State |
Success |
Success |
Node Status |
Up |
Up |
Transport Zones |
- sfo01-w-overlay
- sfo01-w-uplink01
- sfo01-w-uplink02
|
- sfo01-w-overlay
- sfo01-w-uplink01
- sfo01-w-uplink02
|
N-VDS |
3 |
3 |