To provide tenant workloads with routing services and connectivity to networks that are external to the workload domain, deploy two NSX-T Edge nodes.
Table 1.
NSX-T Edge Nodes
Setting |
Value for sfo01wesg01 |
Value for sfo01wesg02 |
Name |
sfo01wesg01 |
sfo01wesg02 |
Port Groups |
sfo01-w-nvds01-management |
sfo01-w-nvds01-management |
Primary IP Address |
172.16.41.21 |
172.16.41.22 |
Procedure
- Log in to vCenter Server by using the vSphere Client.
- Open a Web browser and go to https://sfo01m01vc01.sfo01.rainpole.local/ui.
- Log in by using the following credentials.
Setting |
Value |
User name |
administrator@vsphere.local |
Password |
vsphere_admin_password |
- In the Hosts and Clusters inventory, expand the sfo01w02vc01.sfo01.rainpole.local tree and expand the sfo01-w02dc tree.
- Expand the sfo01-w02-shared01 cluster.
- Right-click the sfo01-w02rp-sddc-edge resource pool and select Deploy OVF Template.
- On the Deploy OVF Template page, navigate to the .ova file of the NSX-T Edge appliance and click Next.
- On the Select name and location page, enter the following settings and click Next.
Setting |
Value |
Name |
sfo01wesg01 |
Folder or data center |
sfo01-w02fd-nsx |
- On the Select a resource page, select the sfo01-w02rp-sddc-edge resource pool and click Next.
- On the Select storage page, select the shared_edge_datastore and click Next.
- On the Select networks page enter the following and click Next.
Source Network |
Destination Network |
Network 3 |
sfo01-w-nvds01-uplink02 |
Network 2 |
sfo01-w-nvds01-uplink01 |
Network 1 |
sfo01-w-overlay |
Network 0 |
sfo01-w-nvds01-management |
- On the Customize template page, expand the setting groups, enter the following settings, and click Next.
Setting |
Value |
System Root User Password / Confirm Password |
nsx_edge_root_password |
CLI "admin" User Password / Confirm Password |
nsx_edge_admin_password |
CLI "audit" User Password / Confirm Password |
nsx_edge_admin_password |
Setting |
Value |
Hostname |
sfo01wesg01.sfo01.rainpole.local |
Default IPv4 Gateway |
172.16.41.253 |
Management Network IPv4 Address |
172.16.41.21 |
Management Network Netmask |
255.255.255.0 |
Setting |
Value |
DNS Server List |
172.16.11.5 172.16.11.4 |
Domain Search List |
sfo01.rainpole.local |
NTP Server List |
ntp.sfo01.rainpole.local |
Enable SSH |
Selected |
Allow root SSH login |
Deselected |
- On the Ready to complete page, click Finish.
- After the deployment finishes, power on the NSX-T Edge appliance.
- In the VMs and Templates inventory, expand the sfo01w02vc01.sfo01.rainpole.local tree.
- Expand the sfo01-w02fd-nsx folder, right-click the sfo01wesg01 virtual machine, and select .
- Repeat this procedure to deploy the sfo01wesg02 NSX-T Edge appliance.