Configure the NSX-T Manager and NSX-T Edge nodes to send audit logs and system events to vRealize Log Insight.
You repeat this procedure for the following NSX-T components.
NSX-T Component |
Hostname |
Managers |
- sfo01wnsx01a.sfo01.rainpole.local
- sfo01wnsx01b.sfo01.rainpole.local
- sfo01wnsx01c.sfo01.rainpole.local
|
Edges |
- sfo01wesg01.sfo01.rainpole.local
- sfo01wesg02.sfo01.rainpole.local
|
Procedure
- Log in to the first NSX-T Manager appliance by using a Secure Shell (SSH) client.
Setting |
Value |
FQDN |
sfo01wnsx01a.sfo01.rainpole.local |
User name |
admin |
Password |
nsx_admin_password |
- To set up log forwarding to vRealize Log Insight, run the command.
set logging-server 192.168.31.10 proto udp level info
- Тo verify that log forwarding is configured, run the command.
- Repeat the procedure for all NSX-T Manager and NSX-T Edge nodes.