Configure the NSX-T Manager and NSX-T Edge nodes to send audit logs and system events to vRealize Log Insight.

You repeat this procedure for the following NSX-T components.
NSX-T Component Hostname
Managers
  • sfo01wnsx01a.sfo01.rainpole.local
  • sfo01wnsx01b.sfo01.rainpole.local
  • sfo01wnsx01c.sfo01.rainpole.local
Edges
  • sfo01wesg01.sfo01.rainpole.local
  • sfo01wesg02.sfo01.rainpole.local

Procedure

  1. Log in to the first NSX-T Manager appliance by using a Secure Shell (SSH) client.
    Setting Value
    FQDN sfo01wnsx01a.sfo01.rainpole.local
    User name admin
    Password nsx_admin_password
  2. To set up log forwarding to vRealize Log Insight, run the command.
    set logging-server 192.168.31.10 proto udp level info
  3. Тo verify that log forwarding is configured, run the command.
    get logging-servers
  4. Repeat the procedure for all NSX-T Manager and NSX-T Edge nodes.