Here is a list of all the out of the box (previously know as system defined) alerts in vRealize Network Insight. To receive notification about any of these alerts, you must enable notification for that particular alert.

OID Alert Parameter Name Default Severity UI Name Alert Name
1.3.6.1.4.1.6876.100.1.0.100001 vmwNSXVLatencyNoDataEvent Warning NSXVLatencyNoDataEvent Network Latency Collection Stopped
1.3.6.1.4.1.6876.100.1.0.100051 vmwVMCVMLimitExceededEvent Critical VMCVMLimitExceededEvent Number of VMs in VMC SDDC exceeds limit.
Note: This alert is deprecated in vRealize Network Insight 6.1.
1.3.6.1.4.1.6876.100.1.0.100052 vmwVMCHostLimitExceededEvent Critical VMCHostLimitExceededEvent Number of Hosts in VMC SDDC exceeds limit.
Note: This alert is deprecated in vRealize Network Insight 6.1.
1.3.6.1.4.1.6876.100.1.0.1510 vmwKubernetesBaseEvent Moderate System Alerts from Kubernetes Alert reported by kubernetes cluster
1.3.6.1.4.1.6876.100.1.0.20001 vmwEntityDiscoveryChangeEvent Info Discovery This alert is raised when any new entity is discovered
1.3.6.1.4.1.6876.100.1.0.20002 vmwEntityPropertiesChangeEvent Info Configuration Change This alert is raised when any property of the entity is changed
1.3.6.1.4.1.6876.100.1.0.20003 vmwFirewallNotInstalledOnHostEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20004 vmwHostWithStaleFirewallRulesEvent Warning Firewall rule table mismatched between host and NSX Manager The distributed firewall rule table differs between the host and NSX Manager.
1.3.6.1.4.1.6876.100.1.0.20005 vmwIpAddressChangeEvent Info IP address change This alert is raised when IP Address of VM is changed
1.3.6.1.4.1.6876.100.1.0.20006 vmwL2GatewayAnomalyEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20007 vmwL2NetworkAddressAnomalyEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20008 vmwL2NetworkDiameterExceededEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20009 vmwL2NetworkUplinkMissingEvent Info Uplink not found for distributed virtual port group VxLan does not have an uplink on specified Host
1.3.6.1.4.1.6876.100.1.0.20010 vmwL2NetworkWithNoVMsEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20011 vmwLayer2NetworkDiameterChangedEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20012 vmwMTUMismatchEvent Warning MTU mismatched between VTEP and physical switch port An MTU mismatch was found in the path between a VTEP and its physical switch port
1.3.6.1.4.1.6876.100.1.0.20013 vmwNetworkIsolationEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20014 vmwNoPathEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20015 vmwSpoofguardDisabledEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20018 vmwVMotionEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20019 vmwVMWithDisconnectedVnicsEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20020 vmwVMWithMulipleVnicsOnDifferentVxlansEvent N/A N/A vm %s is connected to more than one vxlans [%s]
1.3.6.1.4.1.6876.100.1.0.20021 vmwVMWithMulipleVnicsOnSameL2Event N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20022 vmwVMWithNoIpAddressEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20023 vmwVTEPMissingEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20024 vmwL2Event N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20025 vmwMembershipChangeEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20026 vmwSecurityGroupMembershipChangeEvent Info Security Group VM membership change This alert is raised when membership of Security Group is changed
1.3.6.1.4.1.6876.100.1.0.20027 vmwFirewallRuleMembershipChangeEvent Info Firewall Rule VM membership change This alert is raised when membership of Firewall Rule is changed
1.3.6.1.4.1.6876.100.1.0.20028 vmwVlanMembershipChangeEvent Info VLAN VM membership change This alert is raised when membership of Vlan is changed
1.3.6.1.4.1.6876.100.1.0.20029 vmwVxlanMembershipChangeEvent Info VXLAN VM membership change This alert is raised when membership of Vxlan is changed
1.3.6.1.4.1.6876.100.1.0.20030 vmwDeleteChangeEvent Info Delete change This alert is raised when any entity is deleted
1.3.6.1.4.1.6876.100.1.0.20031 vmwVtepFailedPingEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20034 vmwEmptySearchStreamChangeEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20035 vmwSearchStreamMembershipChangeEvent N/A User Defined Change Alert User defined Change Alert
1.3.6.1.4.1.6876.100.1.0.20036 vmwEmptySearchStreamProblemEvent N/A User-defined zero result issue User defined Problem when search result is empty
1.3.6.1.4.1.6876.100.1.0.20037 vmwSearchStreamMembershipProblemEvent N/A User-defined change issue User defined Problem when search result changes
1.3.6.1.4.1.6876.100.1.0.20038 vmwOspfConfigurationMismatchEvent Moderate OSPF area ID mismatched between DLR and Edge router The OSPF area ID differs on connected router interfaces.
1.3.6.1.4.1.6876.100.1.0.20039 vmwServiceVMNotHealthyEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20040 vmwServiceVMNotPoweredOnEvent Critical NSX infrastructure VM not powered on The NSX infrastructure VM found to be in powered off state. Services provided by it may get impacted. The NSX infrastructure includes Controller cluster
1.3.6.1.4.1.6876.100.1.0.20041 vmwServiceVMHighCPUUsageEvent Warning High CPU reported for NSX infrastructure VM An NSX infrastructure VM is experiencing high CPU. This condition may lead to a service disruption.
1.3.6.1.4.1.6876.100.1.0.20042 vmwServiceVMHighMemoryUsageEvent Warning High memory usage reported for NSX infrastructure VM An infrastructure VM is experiencing a high memory condition. This condition may lead to an NSX service disruption.
1.3.6.1.4.1.6876.100.1.0.20043 vmwServiceVMHighDiskUsageEvent Warning High disk usage reported for NSX infrastructure VM Most of the allocated disk space for an infrastructure VM has been consumed. The infrastructure VM may become inaccessible or lead to a service disruption.
1.3.6.1.4.1.6876.100.1.0.20050 vmwIPSetPropertiesChangeEvent Info IP Set properties change This alert is raised when any property of IPSet is changed
1.3.6.1.4.1.6876.100.1.0.20051 vmwFirewallRulePropertiesChangeEvent Info Firewall Rule properties change This alert is raised when any property of Firewall Rule is changed
1.3.6.1.4.1.6876.100.1.0.20052 vmwSecurityGroupPropertiesChangeEvent Info Security Group properties change This alert is raised when any property of Security Group is changed
1.3.6.1.4.1.6876.100.1.0.20053 vmwIPSetMembershipChangeEvent Info IP Set membership change This alert is raised when membership of IPSet is changed
1.3.6.1.4.1.6876.100.1.0.20054 vmwFirewallRuleMaskEvent Warning Firewall rule masked by preceding rule A distributed firewall rule is masked by one or more preceding rules. This condition may indicate a configuration error
1.3.6.1.4.1.6876.100.1.0.20056 vmwSecurityMembershipChangeEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20057 vmwSecurityTagPropertiesChangeEvent Info Security Tag properties change This alert is raised when any property of Security Tag is changed
1.3.6.1.4.1.6876.100.1.0.20058 vmwSecurityTagMembershipChangeEvent Info Security Tag VM membership change This alert is raised when membership of Security Tag is changed
1.3.6.1.4.1.6876.100.1.0.20059 vmwHostDatastoreChangeEvent Info Datastores of Host changed This alert is raised when Host Datastore is changed
1.3.6.1.4.1.6876.100.1.0.20060 vmwVMDatastoreChangeEvent Info Datastores of VM changed This alert is raised when VM Datastore is changed
1.3.6.1.4.1.6876.100.1.0.20061 vmwVMSnapshotChangeEvent Info Snapshots of VM changed This alert is raised when Snapshot of VM is changed
1.3.6.1.4.1.6876.100.1.0.20062 vmwVMVirtualDiskChangeEvent Info Virtual Disks of VM changed This alert is raised when Virtual Disk of VM is changed
1.3.6.1.4.1.6876.100.1.0.20063 vmwIPSetDefinitionMismatchEvent Info IPSet definition mismatched between NSX Managers An IPSet with the same name and different scopes is defined in two NSX Managers. This condition may indicate a configuration error.
1.3.6.1.4.1.6876.100.1.0.20064 vmwSegmentMismatchEvent Info Segment ID ranges overlap between two NSX Managers The VXLAN segment ID ranges defined in different NSX Managers have overlapping ranges
1.3.6.1.4.1.6876.100.1.0.20065 vmwVtepEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20066 vmwVtepConfigurationFaultEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20067 vmwDLRNetworksNotReachableEvent Critical DLR networks unreachable from NSX Edge or external router One or more DLR networks cannot be reached from the uplink interface on the NSX Edge router. This condition suggests either an OSPF configuration error on the Edge-router/DLR or route not configured on uplink router.
1.3.6.1.4.1.6876.100.1.0.20068 vmwVtepSubnetMismatchEvent Moderate VTEP IP subnet mismatched between host(s) and NSX prepared cluster One or more host VTEPs' IP addresses are not on the same subnet as other VTEPs in the same cluster. This condition may result in network connectivity issues
1.3.6.1.4.1.6876.100.1.0.20069 vmwVtepCountMismatchEvent Critical Host's VTEP count mismatched with cluster The host's VTEP count doesn't match the VTEP count of other hosts in the same cluster. VMs on this host connected to a logical switch may not be able to communicate.
1.3.6.1.4.1.6876.100.1.0.20070 vmwEdgeNetworksNotReachableEvent Moderate NSX Edge network unreachable from uplink router One or more networks connected to an NSX Edge router are not reachable from an uplink router.
1.3.6.1.4.1.6876.100.1.0.20089 vmwNiInfraChangeEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.20090 vmwDataSourceEnabledChangeEvent Info Data source has been enabled This alert is raised when data source is enabled
1.3.6.1.4.1.6876.100.1.0.20091 vmwDataSourceDisabledChangeEvent Info Data source has been disabled This alert is raised when data source is disabled
1.3.6.1.4.1.6876.100.1.0.20092 vmwDataSourceCreatedEvent Info Data source has been added This alert is raised when a data source is added
1.3.6.1.4.1.6876.100.1.0.20093 vmwPlatformCpuCoreChangeEvent Info Platform CPU Cores Change This alert is raised when CPU cores on platform is changed
1.3.6.1.4.1.6876.100.1.0.20094 vmwPlatformDiskChangeEvent Info Platform Disk Change This alert is raised when Disk on platform is changed
1.3.6.1.4.1.6876.100.1.0.20095 vmwPlatformMemoryChangeEvent Info Platform Memory Change This alert is raised when memory on platform is changed
1.3.6.1.4.1.6876.100.1.0.20096 vmwPlatformRebootedEvent Info Platform Rebooted This alert is raised when platform is rebooted
1.3.6.1.4.1.6876.100.1.0.20097 vmwProxyCpuCoreChangeEvent Info Proxy CPU Cores Change This alert is raised when CPU cores on collector is changed
1.3.6.1.4.1.6876.100.1.0.20098 vmwProxyDiskChangeEvent Info Proxy Disk Change This alert is raised when Disk on collector is changed
1.3.6.1.4.1.6876.100.1.0.20099 vmwProxyMemoryChangeEvent Info Proxy Memory Change This alert is raised when memory on collector is changed
1.3.6.1.4.1.6876.100.1.0.20100 vmwProxyRebootedEvent Info Proxy Rebooted This alert is raised when collector is rebooted
1.3.6.1.4.1.6876.100.1.0.20101 vmwNIClusterChangeEvent Info Cluster has been expanded This alert is raised when a platform is added to system
1.3.6.1.4.1.6876.100.1.0.20102 vmwNISystemProxyChangeEvent Info Proxy has been added/removed This alert is raised when proxy is added or removed
1.3.6.1.4.1.6876.100.1.0.20103 vmwNIClusterCreateEvent Info Cluster has been created This alert is raised when a cluster is created
1.3.6.1.4.1.6876.100.1.0.30001 vmwThresholdExceededEventCpuReady N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30002 vmwThresholdExceededEventCpuCoStop N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30003 vmwThresholdExceededEventDiskCommandAbortRule N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30004 vmwThresholdExceededEventIODeviceLatencyRule N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30005 vmwThresholdExceededEventIOKernelLatencyRule N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30006 vmwThresholdExceededEventMemorySwapInRule N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30007 vmwThresholdExceededEventMemorySwapOutRule N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30008 vmwThresholdExceededEventNetworkRxDropRule Warning Receive packet drops detected on host interface A threshold-crossing amount of receive-side packet drops have been detected on a host interface.
1.3.6.1.4.1.6876.100.1.0.30009 vmwThresholdExceededEventNetworkTxDropRule Warning Transmit packet drops detected on host interface A threshold-crossing amount of transmit-side packet drops have been detected on a host interface.
1.3.6.1.4.1.6876.100.1.0.30010 vmwAWSRegionSGLimitEvent Critical AWS Security Groups available with AWS Region. AWS Security Groups available with AWS Region.
1.3.6.1.4.1.6876.100.1.0.30011 vmwAWSVPCSGLimitEvent Critical AWS Security Groups available with AWS VPC. AWS Security Groups available with AWS VPC.
1.3.6.1.4.1.6876.100.1.0.30012 vmwAWSSGInboundRuleLimitEvent Critical Inbound Rules available with AWS Security Group. Inbound Rules available with AWS Security Group.
1.3.6.1.4.1.6876.100.1.0.30013 vmwAWSSGOutboundRuleLimitEvent Critical Outbound Rules available with AWS Security Group. Outbound Rules available with AWS Security Group.
1.3.6.1.4.1.6876.100.1.0.30014 vmwAWSInterfaceSGLimitEvent Critical AWS Security Groups available with AWS Interface. AWS Security Groups available with AWS Interface.
1.3.6.1.4.1.6876.100.1.0.30100 vmwPacketDropEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30101 vmwSwitchPortPacketDropEvent Warning Packets dropped on switch port Considerable count of packet drops detected at specified switch port
1.3.6.1.4.1.6876.100.1.0.30102 vmwRouterInterfacePacketDropEvent Warning Packets dropped on NSX Edge Gateway interface A threshold-crossing amount of packet drops have been detected on the vnic interface of an NSX Edge Gateway.
1.3.6.1.4.1.6876.100.1.0.30103 vmwVnicPacketDropEvent Warning Packets dropped at VM A threshold-crossing amount of packet drops have been detected on a VM interface.
1.3.6.1.4.1.6876.100.1.0.30104 vmwVTEPUnderlayPacketDropEvent Moderate VTEP Underlay Packets Drop Considerable count of packets drop detected in VTEP underlay
1.3.6.1.4.1.6876.100.1.0.30105 vmwPnicUnderlyingSwitchPortPacketDropEvent Warning Packets dropped at PNIC underlying switch port A threshold-crossing amount of packet drops have been detected on the switch port associated with the specified physical NIC.
1.3.6.1.4.1.6876.100.1.0.30106 vmwDevicePacketDropEvent Warning Packet drops detected on hardware gateway port A threshold-crossing amount of packet drops have been detected on the specified device.
1.3.6.1.4.1.6876.100.1.0.30110 vmwSwitchPortUptimeThresholdRecededEvent Warning SwitchPortUptimeThresholdRecededEvent Up time receded
1.3.6.1.4.1.6876.100.1.0.30111 SwitchPortOperationalDownEvent Warning Switch Port is operationally down Switch Port is operationally down.
1.3.6.1.4.1.6876.100.1.0.30112 RouterInterfaceOperationalDownEvent Warning Router interface is operationally down Router interface is operationally down.
1.3.6.1.4.1.6876.100.1.0.30116 UnderlayDeviceFanMalFunctionEvent Warning Underlay device fan removed or not working Underlay device fan removed or not working alert.
1.3.6.1.4.1.6876.100.1.0.30117 UnderlayDeviceTemperatureThresholdExceededEvent Warning Underlay device temperature threshold exceeded Underlay device temperature threshold exceeded alert.
1.3.6.1.4.1.6876.100.1.0.30118 UnderlayDeviceFexFanMalFunctionEvent Warning FEX offline Fex fan removed or not working alert.
1.3.6.1.4.1.6876.100.1.0.30119 UnderlayDeviceFexPsMalFunctionEvent Warning Fex power supply removed or not working Fex power supply removed or not working alert.
1.3.6.1.4.1.6876.100.1.0.30120 UnderlayDeviceModuleMalFunctionEvent Warning Underlay device module removed or not working Underlay device module removed or not working alert.
1.3.6.1.4.1.6876.100.1.0.30121 UnderlayDevicePsMalFunctionEvent Warning Underlay device power supply removed or not working Underlay device power supply removed or not working alert.
1.3.6.1.4.1.6876.100.1.0.30122 UnderlayDeviceBfdSessionRemovedEvent Warning Underlay device BFD session deleted Underlay device BFD session deleted alert.
1.3.6.1.4.1.6876.100.1.0.30123 UnderlayDeviceLldpNeighbourRemovedEvent Warning Underlay device LLDP neighbour removed Underlay device LLDP neighbour removed alert
1.3.6.1.4.1.6876.100.1.0.30203 vmwThresholdExceededEventDatastoreFreeSpaceWarning N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30204 vmwThresholdExceededEventDatastoreFreeSpaceCritical N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30205 vmwThresholdExceededEventDatastoreReadLatency N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.30206 vmwThresholdExceededEventDatastoreWriteLatency N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35001 vmwDistributedFirewallApplyHostEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35002 vmwDistributedFirewallApplyVMEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35003 vmwNsxEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35004 vmwFeatureImpactedEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35221 vmwNSXComponentEvent Critical NSX management service not running An NSX management appliance service is down
1.3.6.1.4.1.6876.100.1.0.35222 vmwNSXBackupEvent Info NSX Manager backups not configured NSX Manager backups are not configured. Proper backup of all NSX components is crucial to restore the system to its working state in the alert of a failure
1.3.6.1.4.1.6876.100.1.0.35223 vmwNSXBackupAuditLogExcludedEvent Info Audit logs excluded from NSX Manager backup Audit logs are currently excluded from backup
1.3.6.1.4.1.6876.100.1.0.35224 vmwNSXUnsecureBackupEvent Info NSX Manager backups not configured for SFTP Secure FTP is not currently being used for backups
1.3.6.1.4.1.6876.100.1.0.35225 vmwNSXBackupSystemEventsExcludedEvent Info System alerts excluded from NSX Manager backup System alerts are currently excluded from backup
1.3.6.1.4.1.6876.100.1.0.35226 vmwNSXBackupNotScheduledEvent Info Scheduled NSX Manager backups not enabled Scheduled backups of the environment have not been configured
1.3.6.1.4.1.6876.100.1.0.35227 vmwNSXBackupNotRecordedEvent Info NSX Manager backup not recorded A backup of the environment has not been performed. Proper backup of all NSX components is crucial to restore the system to its working state in the alert of a failure
1.3.6.1.4.1.6876.100.1.0.35228 vmwNSXNtpServerEvent Info NTP server not configured for NSX Manager No NTP server is configured on the NSX Manager
1.3.6.1.4.1.6876.100.1.0.35229 vmwNSXSysLogServerEvent Info Syslog server not configured for NSX Manager There is no syslog server configured on the NSX Manager. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration
1.3.6.1.4.1.6876.100.1.0.35230 vmwControllerSysLogServerEvent Info Syslog server not configured for NSX Controller No syslog server is configured for the NSX Controller. Syslog data is useful for troubleshooting and reviewing data logged during installation and configuration
1.3.6.1.4.1.6876.100.1.0.35231 vmwNSXIpV6EnabledEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.35232 vmwNSXOspfNeighborDownEvent Warning One or more OSPF neighbors unreachable from NSX Edge router One or more OSPF neighbors connected to the NSX Edge are down
1.3.6.1.4.1.6876.100.1.0.36022 vmwClusterFeatureVersionMismatchEvent Info NSX feature version mismatched with ESXi cluster version The NSX feature version of the prepared cluster doesn't match with that of NSX Manager.
1.3.6.1.4.1.6876.100.1.0.36023 vmwHostFeatureVersionMismatchEvent Info NSX feature version mismatched between host and cluster The host's fabric status resource feature version is not same as that of the cluster or NSX Manager
1.3.6.1.4.1.6876.100.1.0.36024 vmwFeatureVersionMismatchEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.36025 vmwHostFeatureEnabledMismatchEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.36026 vmwHostFeatureInstalledMismatchEvent Info Network fabric feature status mismatched between host and cluster The network fabric feature status for a host does not match the status of other hosts in the cluster.
1.3.6.1.4.1.6876.100.1.0.36027 vmwHostVtepNotFoundEvent Critical No VTEP found on prepared host A host in a cluster prepared for NSX is missing at least one VTEP. VMs on this host connected to any logical switch may not be able to communicate.
1.3.6.1.4.1.6876.100.1.0.36028 vmwHostVtepDisconnectedEvent Warning Host's VTEP is administratively disabled The host's VTEP has been disabled and is in a not connected state.
1.3.6.1.4.1.6876.100.1.0.36029 vmwHostVtepEvent Critical Host Vtep Disconnected Host Vtep Disconnected
1.3.6.1.4.1.6876.100.1.0.36030 vmwClusterHostsVtepMTUMismatchEvent Warning VTEP MTU mismatched between host and NSX prepared cluster The VTEP MTU does not match between a host and the NSX prepared cluster.
1.3.6.1.4.1.6876.100.1.0.36031 vmwFeatureUnhealthyEvent Warning Network fabric feature status in errored state The installed NSX feature is reported for some problem by NSX Manager.
1.3.6.1.4.1.6876.100.1.0.36032 vmwEdgeHANotConfiguredEvent Info NSX Edge high availability not enabled High Availability is not enabled on the NSX Edge
1.3.6.1.4.1.6876.100.1.0.36033 vmwEdgeInterfacesDownEvent Warning One or more NSX Edge logical router interfaces are down One or more NSX Edge interfaces are down.
1.3.6.1.4.1.6876.100.1.0.36041 vmwModuleUnhealthyEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.36042 vmwModuleNotLoadedEvent Critical NSX VIB or host module not detected on host At least one of NSX VIB or host module was not detected on the host
1.3.6.1.4.1.6876.100.1.0.36043 vmwModuleNetworkConnectionFailureEvent Critical Message bus and/or control plane connection not established between NSX Manager and host The message bus and/or control plane agent daemon on this Host is experiencing connection failures with NSX Controller or NSX Manager
1.3.6.1.4.1.6876.100.1.0.36044 vmwHostNetworkControlPlaneMismatchEvent Moderate Logical switch table mismatched between host and NSX controller Logical switch information between the primary NSX controller and all hosts where the logical switch is used does not match. This alert may indicate an error condition is occurring after a sharding change.
1.3.6.1.4.1.6876.100.1.0.36045 vmwHostNetworkControlPlaneConnectionFailureEvent Critical Host control plane to controller connection not established for one or more logical switches The connection between the control plane agent on an NSX host and its primary NSX Controller for one or more logical switches is not established. This condition can result in stale information on the host and NSX Controllers.
1.3.6.1.4.1.6876.100.1.0.36046 vmwHostNetworkControlPlaneNotSyncedEvent Moderate Logical networking out of sync between host and NSX Controller The logical switching and routing information on a host is not in sync with the NSX Controller information. To confirm this condition is occurring
1.3.6.1.4.1.6876.100.1.0.36047 vmwNSXControllerClusterMajorityEvent Moderate No NSX controller majority Some of the NSX Controllers in the cluster are not communicating with the NSX Manager
1.3.6.1.4.1.6876.100.1.0.36048 vmwNSXControllersVMOnSameHostEvent Info All controller VMs deployed to same host All NSX Controllers in the cluster are deployed to the same host
1.3.6.1.4.1.6876.100.1.0.36049 vmwVxLanRangeExhaustEvent Warning VXLAN segment ID range reaching exhaustion More than 90% of VXLAN segment IDs have been used
1.3.6.1.4.1.6876.100.1.0.36050 vmwNSXFirewallDefaultAllowAllRulesEvent Info All traffic allowed by default firewall rule The distributed firewall is configured to allow all traffic by default
1.3.6.1.4.1.6876.100.1.0.36051 vmwLogicalRouterNoUplinkEvent Info NSX DLR deployed without an uplink interface The NSX DLR does not have an uplink interface configured
1.3.6.1.4.1.6876.100.1.0.36052 vmwEdgeNotHAEvent Info NSX Edge is configured but not highly available When two Edge VMs have been configured for Edge high availability
1.3.6.1.4.1.6876.100.1.0.36053 vmwEdgeNotDeployedEvent Info NSX Edge deployment failed An NSX Edge has failed to deploy. This condition may indicate that an NSX Edge has been configured without actually being deployed.
1.3.6.1.4.1.6876.100.1.0.36054 vmwEcmpIsEnabledAndStatefulServicesAreUpEvent Info NSX Edge configured with both ECMP and stateful edge services A firewall
1.3.6.1.4.1.6876.100.1.0.36055 vmwLogicalRouterDeployedOnEcmpEdgeHostEvent Info NSX DLR deployed to same host as one or more NSX ECMP Edges The NSX distributed logical router control VM is deployed to the same host as one or more NSX Edges that are configured for ECMP.
1.3.6.1.4.1.6876.100.1.0.36056 vmwEdgeMissingInterfaceOSPFAreaMappingEvent Info Missing NSX Edge interface to OSPF area mapping OSPF is enabled on the NSX Edge
1.3.6.1.4.1.6876.100.1.0.36057 vmwOspfInsecureAuthRouterEvent Info Insecure authentication used in one or more OSPF areas One or more OSPF areas on the NSX Edge Services Gateway or DLR are not configured to use MD5 authentication
1.3.6.1.4.1.6876.100.1.0.36058 vmwNSXControllersDeployedCountEvent Info Incorrect number of deployed NSX Controllers There are fewer than three controllers deployed
1.3.6.1.4.1.6876.100.1.0.36059 vmwNSXControllerNotActiveCountEvent Moderate Less than three active NSX Controllers There are fewer than three active controllers
1.3.6.1.4.1.6876.100.1.0.36060 vmwNSXControllerEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.36061 vmwNSXEcmpEdgeDownEvent Info One or more NSX Edges in the ECMP Cluster are currently down One or more NSX Edges in the ECMP Cluster are currently down
1.3.6.1.4.1.6876.100.1.0.36062 vmwNSXMajorityEcmpEdgesDownEvent Warning Majority of NSX Edges in the ECMP Cluster are currently down Majority of NSX Edges in the ECMP Cluster are currently down
1.3.6.1.4.1.6876.100.1.0.36063 vmwNSXAllEcmpEdgesDownEvent Critical All NSX Edges in the ECMP Cluster are currently down All NSX Edges in the ECMP Cluster are currently down
1.3.6.1.4.1.6876.100.1.0.36064 vmwNSXEdgeMtuMismatchEvent Info The MTU configured on one or more interfaces on the Edge does not match the MTU on the next hop router The MTU configured on one or more interfaces on the Edges in the same Layer 2 network does not match
1.3.6.1.4.1.6876.100.1.0.36065 vmwNSXEdgeSplitBrainEvent Critical Both NSX Edge HA VMs in active state Both VMs of Edge HA are in active state. The most common issue is split-brain
1.3.6.1.4.1.6876.100.1.0.36066 vmwVirtualDistributedRoutingEvent Warning VDR port not found on Host for VxLan routing VDR port is not found on the Host for the specified VxLan
1.3.6.1.4.1.6876.100.1.0.36067 vmwNSXEdgeBGPNeighbourDownEvent Critical One or more BGP neighbours are not in established state One or more BGP neighbours are not in established state.
1.3.6.1.4.1.6876.100.1.0.37001 vmwAnalyticsEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.37002 vmwAnalyticsOutlierEvent N/A Outlier violation alert Alert generated as a result of the anomalous entity
1.3.6.1.4.1.6876.100.1.0.37003 vmwAnalyticsThresholdEvent Critical Threshold violation alert Alert generated as a result of the specified metric crosses the upper or lower bound specified in the configuration
1.3.6.1.4.1.6876.100.1.0.38001 vmwVMCEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.40000 SwitchPortRxNetworkUsageThresholdExceededEvent Warning PNIC Rx Network Utilization is high PNIC utilization exceeds the threshold value of 75%.
1.3.6.1.4.1.6876.100.1.0.40001 vmwCriticalHostNotAccessibleEvent Critical Host with Infrastructure VMs cannot be accessed Host with Infrastructure VMs cannot be accessed
1.3.6.1.4.1.6876.100.1.0.40002 SwitchPortTxNetworkUsageThresholdExceededEvent Warning PNIC Tx Network Utilization is high PNIC utilization exceeds the threshold value of 75%.
1.3.6.1.4.1.6876.100.1.0.40003 SwitchPortRxNetworkUsageThresholdExceededCriticalEvent Critical PNIC Rx Network Utilization is high PNIC utilization exceeds the threshold value of 90%.
1.3.6.1.4.1.6876.100.1.0.40004 SwitchPortTxNetworkUsageThresholdExceededCriticalEvent Critical PNIC Tx Network Utilization is high PNIC utilization exceeds the threshold value of 90%.
1.3.6.1.4.1.6876.100.1.0.40005 ManagementHostHighCPUUsageEvent Warning Management Host CPU Usage Host CPU utilization exceeds the threshold value of 75%.
1.3.6.1.4.1.6876.100.1.0.40006 ManagementHostHighCPUUsageCriticalEvent Critical Management Host CPU Usage Critical alert Host CPU utilization exceeds the threshold value of 90%.
1.3.6.1.4.1.6876.100.1.0.40007 HostUnHealthyEvent Critical Host is not healthy Host is not healthy
1.3.6.1.4.1.6876.100.1.0.40008 FileSystem Disk Available of NSX Controller is Low Critical FileSystem Disk Available of NSX Controller is Low NSX Controller file system disk available percentage less than threshold value.
1.3.6.1.4.1.6876.100.1.0.40011 EdgeVmVnicRxPacketDropEvent Critical Receive packets are getting dropped on the VNIC of Edge VM. Packets are getting dropped on the VNIC of Edge VM. This may impact the network traffic related to management nodes.
1.3.6.1.4.1.6876.100.1.0.40012 EdgeVmVnicTxPacketDropEvent Critical Transmit packets are getting dropped on the VNIC of Edge VM. Packets are getting dropped on the VNIC of Edge VM. This may impact the network traffic related to management nodes.
1.3.6.1.4.1.6876.100.1.0.40013 ManagementHostPnicRxPacketDropEvent Critical Receive packets are getting dropped on the PNIC of the management host. Packets are getting dropped on the pNIC of the management host. This may impact the network traffic related to management nodes.
1.3.6.1.4.1.6876.100.1.0.40014 ManagementHostPnicTxPacketDropEvent Critical Transmit packets are getting dropped on the PNIC of the management host. Packets are getting dropped on the pNIC of the management host. This may impact the network traffic related to management nodes.
1.3.6.1.4.1.6876.100.1.0.40015 ManagementHostConnectionStateDisconnectedEvent Critical Management Host is disconnected vCenter has suspended management of the host. This might be due to - explicitly disconnecting the host, or trying to connect to a host which is in not responding state, or host license has expired. This results in vCenter Server disabling HA on the host and hence, VMs on the host are therefore not failed over in the alert of a host isolation.
1.3.6.1.4.1.6876.100.1.0.568 vmwArkinApplicationMemberLimitEvent Info Application Membership limit exceeded Number of members in application exceeds supported limit
1.3.6.1.4.1.6876.100.1.0.70000 vmwGenericNSXSystemEvent Moderate System Alerts from NSX (warning) NSX System alerts with high or major severity
1.3.6.1.4.1.6876.100.1.0.70001 vmwFilterConfigApplyOnHostFailedEvent Warning Distributed firewall update for host vNIC failed to be applied A distributed firewall configuration update failed to be applied to a vNIC on an NSX prepared host.
1.3.6.1.4.1.6876.100.1.0.70002 vmwRulesetLoadOnHostFailedEvent Warning Distributed firewall update failed to be applied to host A distributed firewall ruleset was not applied to a host.
1.3.6.1.4.1.6876.100.1.0.70003 vmwConfigUpdateOnHostFailedEvent Warning Distributed firewall configuration update failed Firewall configuration update to an NSX host has timed out. The host is not synced with the latest firewall configuration version.
1.3.6.1.4.1.6876.100.1.0.70004 vmwSpoofguardConfigUpdateOnHostFailedEvent Info SpoofGuard configuration update failed An update to the SpoofGuard configuration failed for the host.
1.3.6.1.4.1.6876.100.1.0.70005 vmwApplyRuleToVnicFailedEvent Warning Distributed firewall rule not applied to host vNIC A distributed firewall rule was not applied to a host's vNIC.
1.3.6.1.4.1.6876.100.1.0.70006 vmwContainerConfigUpdateOnVnicFailedEvent Warning Distributed firewall container update failed on host Network and security container information used with the NSX distributed firewall or with Service Composer failed to be updated on an NSX host.
1.3.6.1.4.1.6876.100.1.0.70007 vmwSpoofguardApplyToVnicFailedEvent Info SpoofGuard initial configuration failed The SpoofGuard configuration was not applied to the specified vNIC on the host.
1.3.6.1.4.1.6876.100.1.0.70008 vmwHostMessagingConfigurationFailedEvent Warning Host messaging configuration update failed A configuration update pushed to hosts over the NSX messaging channel did not complete.
1.3.6.1.4.1.6876.100.1.0.70009 vmwHostMessagingConnectionReconfigurationFailedEvent Warning Host messaging connection re-config failed Updated information on the host messaging channel failed to be sent to the NSX host.
1.3.6.1.4.1.6876.100.1.0.70010 vmwHostMessagingConfigurationFailedNotificationSkippedEvent Warning Host messaging channel between host and NSX Manager failed to re-establish NSX Manager attempted to re-establish the message bus channel when the prepared host connected back to vCenter Server. This connection again failed
1.3.6.1.4.1.6876.100.1.0.70011 vmwHostMessagingInfrastructureDownEvent Warning Host messaging infrastructure down on host Two or more messaging-channel heartbeat messages between NSX Manager and an NSX host were missed.
1.3.6.1.4.1.6876.100.1.0.70012 vmwEdgeVMNotRespondingEvent Moderate NSX Edge to NSX Manager heartbeat failed An NSX Edge VM is not responding to health check by NSX Manager
1.3.6.1.4.1.6876.100.1.0.70013 vmwEdgeUnhealthyEvent Critical NSX Edge VM not in active/self state NSX Edge VM is reporting a problematic state and might not be functioning correctly.
1.3.6.1.4.1.6876.100.1.0.70014 vmwEdgeVMCommunicationFailureEvent Critical NSX Manager to Edge VM communication failure Communication failure detected between NSX Manager and Edge VM.
1.3.6.1.4.1.6876.100.1.0.70015 vmwNSXEdgeEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.71000 vmwOtherCriticalNSXEvent Critical System Alerts from NSX (Critical) NSX System alerts with critical severity.
1.3.6.1.4.1.6876.100.1.0.80001 vmwPanNsxNotInRegisteredStateEvent Critical Palo Alto Panorama not registered with NSX Manager Panorama is not in a registered state with NSX Manager.
1.3.6.1.4.1.6876.100.1.0.80002 vmwPanNsxDynamicUpdateDelayedEvent Warning Panorama dynamic membership definition update delayed Panorama dynamic membership definition update from NSX Manager is delayed. This condition may indicate a network connectivity issue or an issue with NSX Manager's NetX service.
1.3.6.1.4.1.6876.100.1.0.80003 vmwPanDeviceInDisconnectedStateEvent Warning Palo Alto service VM not connected to Panorama A service VM or device for Palo Alto Networks is in a not connected state with Panorama
1.3.6.1.4.1.6876.100.1.0.80004 vmwPanNsxServiceApplianceViewMismatchEvent Critical Service VM's status mismatched between Panorama and NSX Manager Mismatch in service appliance information between NSX Manager and Panorama.
1.3.6.1.4.1.6876.100.1.0.80005 vmwPanNsxFabricAgentNotFoundOnHostEvent Critical NSX Fabric Agent not found on Host Security Fabric Agent not reported by NSX for a Host where as the Cluster is prepped
1.3.6.1.4.1.6876.100.1.0.80006 vmwPanNsxServiceVMNotFoundOnHostEvent Critical Palo Alto service VM not found on host A Palo Alto Networks' security appliance VM was not found on a host in an NSX prepared cluster.
1.3.6.1.4.1.6876.100.1.0.80100 vmwCheckpointEvent N/A N/A N/A
1.3.6.1.4.1.6876.100.1.0.80102 vmwCheckpointNsxFabricAgentNotFoundOnHostEvent Critical CheckpointNsxFabricAgentNotFoundOnHostEvent Security Fabric Agent not reported by NSX for a Host where as the Cluster is prepped
1.3.6.1.4.1.6876.100.1.0.80103 vmwCheckpointNsxServiceVMNotFoundOnHostEvent Critical CheckpointNsxServiceVMNotFoundOnHostEvent A Check Point' security appliance VM was not found on a host in an NSX prepared cluster.
1.3.6.1.4.1.6876.100.1.0.80104 vmwCheckpointGatewaySicStatusNotCommunicatingEvent Critical CheckpointGatewaySicStatusNotCommunicatingEvent A service VM or gateway for Check Point does not have 'communicating' SIC status
1.3.6.1.4.1.6876.100.1.0.80105 vmwCheckpointNsxServiceApplianceViewMismatchEvent Critical Service VM's status mismatched between Check Point and NSX Manager Mismatch in service appliance information between NSX Manager and Check Point.
1.3.6.1.4.1.6876.100.1.0.80200 NSXTEvent N/A NSX-T System alert Alarm/Event generated by NSX-T platform
1.3.6.1.4.1.6876.100.1.0.80201 NSXTVcNotAddedEvent Warning One or more vCenter servers not added as data source in vRNI NSX-T has one or more Compute Managers which are not added as data sources in vRNI with same IP or FQDN.
1.3.6.1.4.1.6876.100.1.0.80202 NSXTStandaloneHostsEvent Warning One or more Fabric Nodes are added as standalone hosts in NSX-T One or more Fabric Nodes are added as standalone hosts in NSX-T. Virtual Machines on those hosts will not be visible in vRNI.
1.3.6.1.4.1.6876.100.1.0.80203 vmwNSXTSystemEvent N/A System Alerts from NSX-T Alarm generated by NSX-T platform
1.3.6.1.4.1.6876.100.1.0.80205 NSXTNoUplinkConnectivityEvent Warning NSX-T Tier-1 logical router disconnected NSX-T Tier-1 logical router is disconnected from Tier-0 router. Networks under this router are not reachable from outside and vice versa.
1.3.6.1.4.1.6876.100.1.0.80206 NSXTRoutingAdvertisementEvent Warning Routing advertisement disabled Routing advertisement is disabled for NSX-T Tier-1 logical router. Networks under this router are not reachable from outside.
1.3.6.1.4.1.6876.100.1.0.80207 NSXTManagerConnectivityDownEvent Critical NSX-T Edge Node has no manager connectivity NSX-T Edge Node has lost manager connectivity.
1.3.6.1.4.1.6876.100.1.0.80208 NSXTControllerConnectivityDegradedEvent Warning Controller connectivity degraded for NSX-T Edge Node NSX-T Edge Node is not able to communicate with one or more controllers.
1.3.6.1.4.1.6876.100.1.0.80209 NSXTControllerConnectivityDownEvent Critical NSX-T Edge Node has no controller connectivity NSX-T Edge Node is not able to communicate with any of the controllers.
1.3.6.1.4.1.6876.100.1.0.80210 NSXTMtuMismatchEvent Warning MTU mismatch between NSX-T Tier-0 and uplink switch/router The MTU configured on interfaces of Tier-0 logical router does not match with the interfaces of uplink switch/router from same L2 network. This can impact the network performance.
1.3.6.1.4.1.6876.100.1.0.80211 NSXTExcludedVmFlowEvent Info One or More VMs excluded from NSX-T DFW Firewall. One or more VMs are not protected by NSX-T DFW firewall. vRealize Network Insight will not receive IPFIX flows for these VMs.
1.3.6.1.4.1.6876.100.1.0.80212 NSXTDoubleVlanTaggingEvent Warning Uplink Vlan misconfiguration Communication is disrupted because VLAN on uplink port of Tier 0 router is different than VLAN on the external gateway.
1.3.6.1.4.1.6876.100.1.0.80213 NSXTNoTzAttachedOnTnEvent Warning No transport zone is attached to the transport node. No transport zone attached to the transport node. VMs might lose connectivity because of this.
1.3.6.1.4.1.6876.100.1.0.80214 NSXTVtepDeleteEvent Warning No VTEP available on the transport node. All vteps are deleted from the transport node. VMs might lose connectivity because of this.
1.3.6.1.4.1.6876.100.1.0.80215 vmwDuplicateL3SwitchEvent Critical Same Switch or Router added Same Switch or Router is added with different IPs. VM to VM path may not be generated.
1.3.6.1.4.1.6876.100.1.0.80216 vmwLBPoolMemberDownEvent Critical Pool Member Down This alert is raised when pool member of load balancer is down. To know the pool members which are down, search 'Pool Member where state = DISABLED'
1.3.6.1.4.1.6876.100.1.0.80217 vmwLBPoolDownEvent Critical Pool Down This alert is raised when pool of load balancer is down
1.3.6.1.4.1.6876.100.1.0.80218 vmwLBPoolEmptyEvent Critical Pool Empty This alert is raised when pool of load balancer is empty. To know pools which are empty, search 'Pool where PoolMembers Count = 0'
1.3.6.1.4.1.6876.100.1.0.80219 vmwLBPoolMemberVMDownEvent Critical VM of Pool Member Down This alert is raised when VM associated with pool member of load balancer is down
1.3.6.1.4.1.6876.100.1.0.80220 vmwLBVirtualServerDisableEvent Critical Virtual Server of Load Balancer Disabled This alert is raised when virtual server of load balancer is disabled
1.3.6.1.4.1.6876.100.1.0.80221 vmwLBServiceNodeIPNotFoundEvent Critical IP of Service Node not found This alert is raised when no NIC associated with IP of service node of load balancer is found
1.3.6.1.4.1.6876.100.1.0.80222 vmwLBServiceNodeMultipleNicFoundEvent Critical Multiple NIC of Service Node found This alert is raised when multiple NICs associated with IP of service node of load balancer are found
1.3.6.1.4.1.6876.100.1.0.80223 NSXTSwitchIpfixEnabledEvent Warning NSX-T Switch IPFIX is enabled and has a collector profile pointing to one of the vRNI collectors. Network Insight does not support the IPFIX flow data from NSX-T Switches. It is configured to send IPFIX data to one of the Network Insight Collector VM. It may have corrupted existing flow data in the system.
1.3.6.1.4.1.6876.100.1.0.80224 NSXTStandaloneHostsWithoutVcEvent Critical vCenter managing one or more fabric nodes in NSX-T is not added as a data source in vRNI vCenter managing one or more fabric nodes in NSX-T is not added as a data source in vRNI. Virtual Machines on those hosts will not be visible in vRNI.
1.3.6.1.4.1.6876.100.1.0.80225 NSXTControllerNodeToControlClusterConnectivityEvent Critical NSX-T controller node has no control cluster connectivity NSX-T controller node has lost control cluster connectivity.
1.3.6.1.4.1.6876.100.1.0.80226 NSXTControllerNodeToMgmtPlaneConnectivityEvent Critical NSX-T controller node has no management plane connectivity NSX-T controller node has lost management plane connectivity.
1.3.6.1.4.1.6876.100.1.0.80227 NSXTMPNodeToMgmtClusterConnectivityEvent Critical NSX-T management node has no management cluster connectivity NSX-T management node has lost management cluster connectivity.

1.3.6.1.4.1.6876.100.1.0.80228

NSXTHostNodePnicStatusDownEvent Warning

NSX-T Host Transport Node Pnic Status is 'Down'.

NSX-T Host Transport Node Pnic Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80229

NSXTHostNodePnicStatusDegradedEvent Warning

NSX-T Host Transport Node Pnic Status is 'Degraded'

NSX-T Host Transport Node Pnic Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80230

NSXTHostNodePnicStatusUnknownEvent

Warning

NSX-T Host Transport Node Pnic Status is 'Unknown'.

NSX-T Host Transport Node Pnic Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80231

NSXTHostNodeTunnelStatusDownEvent

Warning

NSX-T Host Transport Node Tunnel Status is 'Down'.

NSX-T Host Transport Node Tunnel Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80232

NSXTHostNodeTunnelStatusDegradedEvent

Warning

NSX-T Host Transport Node Tunnel Status is 'Degraded'.

NSX-T Host Transport Node Tunnel Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80233

NSXTHostNodeTunnelStatusUnknownEvent

Warning

NSX-T Host Transport Node Tunnel Status is 'Unknown'.

NSX-T Host Transport Node Tunnel Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80234

NSXTHostNodeStatusDownEvent

Warning

NSX-T Host Transport Node Status is 'Down'.

NSX-T Host Transport Node Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80235

NSXTHostNodeStatusDegradedEvent

Warning

NSX-T Host Transport Node Status is 'Degraded'.

NSX-T Host Transport Node Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80236

NSXTHostNodeStatusUnknownEvent

Warning

NSX-T Host Transport Node Status is 'Unknown'.

NSX-T Host Transport Node Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80237

NSXTEdgeNodePnicStatusDownEvent

Critical

NSX-T Edge Transport Node Pnic Status is 'Down'.

NSX-T Edge Transport Node Pnic Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80238

NSXTEdgeNodePnicStatusDegradedEvent

Critical

NSX-T Edge Transport Node Pnic Status is 'Degraded'.

NSX-T Edge Transport Node Pnic Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80239

NSXTEdgeNodePnicStatusUnknownEvent

Critical

NSX-T Edge Transport Node Pnic Status is 'Unknown'.

NSX-T Edge Transport Node Pnic Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80240

NSXTEdgeNodeTunnelStatusDownEvent

Critical

NSX-T Edge Transport Node Tunnel Status is 'Down'.

NSX-T Edge Transport Node Tunnel Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80241

NSXTEdgeNodeTunnelStatusDegradeEvent

Critical

NSX-T Edge Transport Node Tunnel Status is 'Degraded'.

NSX-T Edge Transport Node Tunnel Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80242

NSXTEdgeNodeTunnelStatusUnknownEvent

Critical

NSX-T Edge Transport Node Tunnel Status is 'Unknown'.

NSX-T Edge Transport Node Tunnel Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80243

NSXTEdgeNodeStatusDownEvent

Critical

NSX-T Edge Transport Node Status is 'Down'.

NSX-T Edge Transport Node Status is 'Down'.

1.3.6.1.4.1.6876.100.1.0.80244

NSXTEdgeNodeStatusDegradedEvent

Critical

NSX-T Edge Transport Node Status is 'Degraded'.

NSX-T Edge Transport Node Status is 'Degraded'.

1.3.6.1.4.1.6876.100.1.0.80245

NSXTEdgeNodeStatusUnknownEvent

Critical

NSX-T Edge Transport Node Status is 'Unknown'.

NSX-T Edge Transport Node Status is 'Unknown'.

1.3.6.1.4.1.6876.100.1.0.80246

NSXTHostNodeMgmtConnectivityStatusDownEvent

Warning

NSX-T Host Node has no manager connectivity

Desynchronization between NSX Manager's State of connectivity with Host Transport Nodes

1.3.6.1.4.1.6876.100.1.0.80247

NSXTEdgeNodeCtlrConnectivityStatusUnknownEvent Critical

Controller connectivity for NSX-T Edge Node is Unknown.

NSX-T Edge Node Controller connectivity is Unknown.

1.3.6.1.4.1.6876.100.1.0.80248

NSXTHostNodeCtlrConnectivityStatusDownEvent Warning

NSX-T Host Node has no controller connectivity

NSX-T Host Node is not able to communicate with any of the controllers.

1.3.6.1.4.1.6876.100.1.0.80249

NSXTHostNodeCtlrConnectivityStatusDegradedEvent Warning

Controller connectivity degraded for NSX-T Host Node

NSX-T Host Node is not able to to communicate with one or more controllers.

1.3.6.1.4.1.6876.100.1.0.80250

NSXTHostNodeCtlrConnectivityStatusUnknownEvent Warning

Controller connectivity for NSX-T Host Node is Unknown.

NSX-T Host Node Controller connectivity is Unknown.

1.3.6.1.4.1.6876.100.1.0.80252 NSXTLogicalSwitchAdminStatusDownEvent Warning NSX-T Logical Switch Admin Status is 'Down' NSX-T Logical Switch Admin Status is 'Down'
1.3.6.1.4.1.6876.100.1.0.80253 NSXTLogicalPortOperationalStatusDownEvent Critical NSX-T Logical Port Operational Status is 'Down' NSX-T Logical Port Operational Status is 'Down'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another.
1.3.6.1.4.1.6876.100.1.0.80254 NSXTLogicalPortOperationalStatusUnknownEvent Warning NSX-T Logical Port Operational Status is 'Unknown' NSX-T Logical Port Operational Status is 'Unknown'. This could cause a communication failure between two virtual interfaces (VIFs) that are connected to the same logical switch, for example, you cannot ping one VM from another.
1.3.6.1.4.1.6876.100.1.0.80255 NSXTComputeManagerConnectionStatusNotUpEvent Warning NSX-T Compute Manager Connection Status in not up NSX-T Compute Manager Connection status is not up
1.3.6.1.4.1.6876.100.1.0.80256 NSXTClusterBackUpDisabledEvent Warning NSX-T Manager backup is not scheduled. NSX-T Manager backup is not scheduled
1.3.6.1.4.1.6876.100.1.0.80257 NSXTDFWFirewallDisabledEvent Critical NSX-T DFW Firewall is disabled. Distributed Firewall is disabled in the NSX-T Manager
1.3.6.1.4.1.6876.100.1.0.80258 NSXTLogicalPortReceivedPacketDropEvent Warning NSX-T Logical Port Received Packets are getting dropped. Received packets are getting dropped on the NSX-T Logical Port and associated entities might get affected
1.3.6.1.4.1.6876.100.1.0.80259 NSXTLogicalPortTransmittedPacketDropEvent Warning NSX-T Logical Port Transmitted Packets are getting dropped. Transmitted packets are getting dropped on the NSX-T Logical Port and associated entities might get affected
1.3.6.1.4.1.6876.100.1.0.80260 NSXTLogicalSwitchReceivedPacketDropEvent Warning NSX-T Logical Switch Received Packets are getting dropped Received packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected
1.3.6.1.4.1.6876.100.1.0.80261 NSXTLogicalSwitchTransmittedPacketDropEvent Warning NSX-T Logical Switch Transmitted Packets are getting dropped Transmitted packets are getting dropped on the NSX-T Logical Switch and associated entities might get affected
1.3.6.1.4.1.6876.100.1.0.80262 NSXTRxPacketDropOnMPNicEvent Warning Received packets are dropping on NSX-T Management Node's network interface Received packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster.
1.3.6.1.4.1.6876.100.1.0.80263 NSXTRxPacketDropOnEdgeTnNicEvent Critical Received packets are dropping on NSX-T Edge Node's network interface Received packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster.
1.3.6.1.4.1.6876.100.1.0.80264 NSXTRxPacketDropOnHostTnNicEvent Warning Received packets are dropping on NSX-T Host Node's network interface Received packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host.
1.3.6.1.4.1.6876.100.1.0.80265 NSXTTxPacketDropOnMPNicEvent Warning Transmitted packets are dropping on NSX-T Management Node's network interface Transmitted packets are getting dropped on NSX-T Management Node's network interface. This may impact the network traffic related to NSX-T management cluster.
1.3.6.1.4.1.6876.100.1.0.80266 NSXTTxPacketDropOnEdgeTnNicEvent Critical Transmitted packets are dropping on NSX-T Edge Node's network interface Transmitted packets are getting dropped on NSX-T Edge Node's network interface. This may impact the network traffic of edge cluster.
1.3.6.1.4.1.6876.100.1.0.80267 NSXTTxPacketDropOnHostTnNicEvent Warning Transmitted packets are dropping on NSX-T Host Node's network interface Transmitted packets are getting dropped on NSX-T Host Node's network interface. This may impact the network traffic on ESXi Host.
1.3.6.1.4.1.6876.100.1.0.80301 vmwHardwareVTEPMismatchEvent Critical HardwareVTEPMismatchEvent Hardware Gateway Bindings Mismatch
1.3.6.1.4.1.6876.100.1.0.80302 vmwHardwareVTEPPortDownEvent Critical HardwareVTEPPortDownEvent Hardware Gateway Port Down
1.3.6.1.4.1.6876.100.1.0.80402 NSXTMPNodeServiceCmInventoryStatusEvent Warning CM Inventory Serivce has stopped running CM Inventory Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80402 NSXTMPNodeServiceCmInventoryStatusEvent Critical CM Inventory Serivce has stopped One of the Services of the NSX-T Management Node, namely CM Inventory Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80403 NSXTMPNodeServiceControllerStatusEvent Warning Controller Service has stopped running. Controller Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80403 NSXTMPNodeServiceControllerStatusEvent Critical Controller Service has stopped One of the Services of the NSX-T Management Node, namely Controller Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80404 NSXTMPNodeServiceDataStoreStatusEvent Warning

DataStore Service has stopped running.

DataStore Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80404 NSXTMPNodeServiceDataStoreStatusEvent Critical DataStore Service has stopped One of the Services of the NSX-T Management Node, namely DataStore Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80405 NSXTMPNodeServiceHttpStatusEvent Warning HTTP Service has stopped running.

HTTP Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80405 NSXTMPNodeServiceHttpStatusEvent Critical HTTP Service has stopped One of the Services of the NSX-T Management Node, namely HTTP Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80406 NSXTMPNodeServiceInstallUpgradeEvent Warning Install Upgrade Service has stopped running. Install Upgrade Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80406 NSXTMPNodeServiceInstallUpgradeEvent Warning Install Upgrade Service has stopped One of the Services of the NSX-T Management Node, namely Install Upgrade Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80407 NSXTMPNodeServiceLiagentStatusEvent Warning

Liagent service has stopped running.

Liagent Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80407 NSXTMPNodeServiceLiagentStatusEvent Warning Liagent service has stopped One of the Services of the NSX-T Management Node, namely LI Agent Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80408 NSXTMPNodeServiceManagerStatusEvent Warning Manager Service has stopped running. Manager Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80408 NSXTMPNodeServiceManagerStatusEvent Critical Manager Service has stopped One of the Services of the NSX-T Management Node, namely Manager Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80409 NSXTMPNodeServiceMgmtPlaneBusStatusEvent Warning Management Plane Service has stopped running. Management Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80409 NSXTMPNodeServiceMgmtPlaneBusStatusEvent Warning Management Plane Service has stopped One of the Services of the NSX-T Management Node, namely Management Plane Bus Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80410 NSXTMPNodeServiceMigrationCoordinatorStatusEvent Warning

Migration Co-ordinator Service has stopped running.

Migration Co-ordinator Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80410 NSXTMPNodeServiceMigrationCoordinatorStatusEvent Warning Migration Co-ordinator Service has stopped One of the Services of the NSX-T Management Node, namely Migration Co-ordinator Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80411 NSXTMPNodeServiceNodeMgmtStatusEvent Warning Node Management Service has stopped running. Node Management Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80411 NSXTMPNodeServiceNodeMgmtStatusEvent Critical Node Management Service has stopped One of the Services of the NSX-T Management Node, namely Node Management Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80412 NSXTMPNodeServiceNodeStatsStatusEvent Warning Node Statistics Service has stopped running. Node Statistics Service status has turned to stopped.
1.3.6.1.4.1.6876.100.1.0.80412 NSXTMPNodeServiceNodeStatsStatusEvent Critical Node Statistics Service has stopped One of the Services of the NSX-T Management Node, namely Node Statistics has stopped running.
1.3.6.1.4.1.6876.100.1.0.80413 NSXTMPNodeServiceNSXMessageBusStatusEvent Warning Message Bus Service has stopped running.

Message Bus Client Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80413 NSXTMPNodeServiceNSXMessageBusStatusEvent Warning Message Bus Service has stopped One of the Services of the NSX-T Management Node, namely Message Bus Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80414 NSXTMPNodeServiceNSXPlatformClientStatusEvent Warning Platform Client Service has stopped running.

Platform Client Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80414 NSXTMPNodeServiceNSXPlatformClientStatusEvent Critical Platform Client Service has stopped One of the Services of the NSX-T Management Node, namely Platform Client Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80415 NSXTMPNodeServiceNSXUpgradeAgentStatusEvent Warning Upgrade Agent Service has stopped running.

Upgrade Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80415 NSXTMPNodeServiceNSXUpgradeAgentStatusEvent Warning Upgrade Agent Service has stopped One of the Services of the NSX-T Management Node, namely Upgrade Agent Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80416 NSXTMPNodeServiceNTPStatusEvent Warning NTP Service has stopped running.

NTP Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80416 NSXTMPNodeServiceNTPStatusEvent Critical NTP Service has stopped One of the Services of the NSX-T Management Node, namely NTP Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80417 NSXTMPNodeServicePolicyStatusEvent Warning Policy Service has stopped running.

Policy Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80417 NSXTMPNodeServicePolicyStatusEvent Critical Policy Service has stopped One of the Services of the NSX-T Management Node, namely Policy Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80418 NSXTMPNodeServiceSearchStatusEvent Warning Search Service has stopped running.

Search Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80418 NSXTMPNodeServiceSearchStatusEvent Critical Search Service has stopped One of the Services of the NSX-T Management Node, namely Search Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80419 NSXTMPNodeServiceSNMPStatusEvent Warning

SNMP Service has stopped running.

SNMP Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80419 NSXTMPNodeServiceSNMPStatusEvent Warning SNMP Service has stopped One of the Services of the NSX-T Management Node, namely SNMP Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80420 NSXTMPNodeServiceSSHStatusEvent Warning SSH Service has stopped running.

SSH Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80420 NSXTMPNodeServiceSSHStatusEvent Critical SSH Service has stopped One of the Services of the NSX-T Management Node, namely SSH Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80421 NSXTMPNodeServiceSyslogStatusEvent Warning Syslog Service has stopped running.

Syslog Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80421 NSXTMPNodeServiceSyslogStatusEvent Critical Syslog Service has stopped One of the Services of the NSX-T Management Node, namely Syslog Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80422 NSXTMPNodeServiceTelemetryStatusEvent Warning

Telemetry Service has stopped running.

Telemetry Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80422 NSXTMPNodeServiceTelemetryStatusEvent Warning Telemetry Service has stopped One of the Services of the NSX-T Management Node, namely Telemetry Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80423 NSXTMPNodeServiceUIServiceStatusEvent Warning

UI Service has stopped running.

UI Service status has turned to stopped.

1.3.6.1.4.1.6876.100.1.0.80423 NSXTMPNodeServiceUIServiceStatusEvent Critical UI Service has stopped One of the Services of the NSX-T Management Node, namely UI Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80424 NSXTMPNodeServiceClusterManagerStatusEvent Critical Cluster Manager Service has stopped One of the Services of the NSX-T Management Node, namely Cluster Manager Service has stopped running.
1.3.6.1.4.1.6876.100.1.0.80501 vmwIndexerLagEvent Critical Indexer Lag Alert Recent data is still being indexed. Search results may be inaccurate.
1.3.6.1.4.1.6876.100.1.0.80502 vmwIPFIXFlowDPPausedEvent Critical IPFIX Flow Data Source Paused alert Ipfix Flow Data Source has been paused due to large number of flows.
1.3.6.1.4.1.6876.100.1.0.80503 vmwGridProcessingStoppedEvent Critical Grid Processing Stopped Grid processing has stopped.
1.3.6.1.4.1.6876.100.1.0.80504 vmwUnableToSendEmailsEvent Critical Unable to Send Emails message Unable to send email message.
1.3.6.1.4.1.6876.100.1.0.80505 vmwSMTPNotConfiguredEvent Critical SMTP Not Configured SMTP Not Configured
1.3.6.1.4.1.6876.100.1.0.80506 vmwSNMPNotConfiguredEvent Critical SMTP Not Configured No SNMP Targets are configured.
1.3.6.1.4.1.6876.100.1.0.80507 vmwReindexingInProgressEvent Critical Reindexing in Process Data is currently being re-indexed. Search service will be available after this migration activity is complete.
1.3.6.1.4.1.6876.100.1.0.80508 vmwNodesVersionMismatchEvent Critical Nodes Version Mismatch Nodes Version Mismatch detected
1.3.6.1.4.1.6876.100.1.0.80509 vmwNotAllServicesRunningEvent Critical Not All Services Running One or more essential services are not running.
1.3.6.1.4.1.6876.100.1.0.80510 vmwNotAllServicesHealthyEvent Critical Not All Services Healthy One or more essential services are not healthy.
1.3.6.1.4.1.6876.100.1.0.80511 vmwExpandPartitionFailedEvent Critical Expand Partition Failed Failed to expand disk partition.
1.3.6.1.4.1.6876.100.1.0.80512 vmwDiskCleanupFailedEvent Critical Disk Cleanup Failed Disk Cleanup service is unhealthy.
1.3.6.1.4.1.6876.100.1.0.80513 vmwVacuumFailedEvent Critical Vacuum Failed PostgreSQL Vacuum service is unhealthy.
1.3.6.1.4.1.6876.100.1.0.80514 vmwConfigStoreCleanupFailedEvent Critical Config Store Cleanup Failed Data Retention (Config Store Maintenance) service is unhealthy.
1.3.6.1.4.1.6876.100.1.0.80515 vmwHBaseRetentionToolFailedEvent Critical HBASE Retention Tool Failed Data Retention (Metric Retention Configuration) service is unhealthy.
1.3.6.1.4.1.6876.100.1.0.80516 vmwMetricStoreUpdaterFailedEvent Critical Metric Store Updater Failed Data Retention (Metric Store Maintenance) service is unhealthy.
1.3.6.1.4.1.6876.100.1.0.80517 vmwCollectorLagEvent Critical Collecter Lag Last data collection on collector was more than threshold ago
1.3.6.1.4.1.6876.100.1.0.80518 vmwCollectionLagEvent Critical Collection Lag Last data collection on data source was more than threshold ago
1.3.6.1.4.1.6876.100.1.0.80519 vmwGridProcessingLagEvent Critical Grid Processing Lag Grid processing is lagging by more than threshold ago
1.3.6.1.4.1.6876.100.1.0.80520 vmwConnectionErrorEvent Critical Connection Error Error connecting to data source
1.3.6.1.4.1.6876.100.1.0.80521 vmwNodeNotActiveEvent Critical Node Not Active Node Not Active
1.3.6.1.4.1.6876.100.1.0.80522 vmwHighDiskUtilizationEvent Critical High Disk Utilization High Disk Utilization
1.3.6.1.4.1.6876.100.1.0.80523 vmwIndexingAbortedEvent Critical Indexing Aborted Indexing Aborted
1.3.6.1.4.1.6876.100.1.0.80524 vmwUpgradeFailedEvent Critical Upgrade Failed Upgrade Failed
1.3.6.1.4.1.6876.100.1.0.80525 vmwFlowProcessingSuspendedEvent Critical Flow Processing Suspended Flow processing suspended
1.3.6.1.4.1.6876.100.1.0.80526 vmwLargeSdmsDroppedEvent Critical Data Processing Error Large SDMS Dropped
1.3.6.1.4.1.6876.100.1.0.80527 vmwApplianceNotConfiguredEvent Critical Appliance Not Configured Collector VM configuration incomplete.
1.3.6.1.4.1.6876.100.1.0.80531 vmwFdbConfigStoreCleanupFailedEvent FDB_CONFIG_STORE_CLEANUP_FAILED_EVENT FDB Config Store Cleanup Failed
1.3.6.1.4.1.6876.100.1.0.80531 vmwDiskAllocationInsufficientEvent Info DISK_ALLOCATION_INSUFFICIENT_EVENT Disk Not Configured
1.3.6.1.4.1.6876.100.1.0.80601 vmwFailedEvent Critical Data Source Failed Data Source Failed
1.3.6.1.4.1.6876.100.1.0.80602 vmwTimeoutEvent Critical Data Source Timeout Data Source Timeout
1.3.6.1.4.1.6876.100.1.0.80603 vmwConnectionRefusedEvent Critical Connection Refused Connection Refused
1.3.6.1.4.1.6876.100.1.0.80605 vmwIncorrectConnectionStringEvent Critical Incorrect Connection String Incorrect Connection String
1.3.6.1.4.1.6876.100.1.0.80606 vmwInvalidCredentialsEvent Critical Invalid Credentials Invalid Credentials
1.3.6.1.4.1.6876.100.1.0.80608 vmwUnknownHostEvent Critical Unknown Host Unknown Host
1.3.6.1.4.1.6876.100.1.0.80609 vmwSNMPConnectionInvalidEvent Critical Invalid SNMP Connection Invalid SNMP Connection
1.3.6.1.4.1.6876.100.1.0.806100012 vmwPwdAuthModeDisabledAristaEvent Critical Password Authentication Disabled Password Authentication Disabled
1.3.6.1.4.1.6876.100.1.0.806100018 vmwUnsupportedNSXVersionEvent Critical Unsupported NSX Version Unsupported NSX Version
1.3.6.1.4.1.6876.100.1.0.80611 vmwFailedCredsEncryptEvent Critical Credential Encryption Failed Credential Encryption Failed
1.3.6.1.4.1.6876.100.1.0.80612 vmwPwdAuthModeDisabledEvent Critical Password Authentication Mode Disabled Password Authentication Mode Disabled
1.3.6.1.4.1.6876.100.1.0.80613 vmwInsufficientPrivilegesEvent Critical Insufficient Privileges Insufficient Privileges
1.3.6.1.4.1.6876.100.1.0.8061313 vmwFlowCollectionErrorEvent Critical Flow Collection Error Flow Collection Error
1.3.6.1.4.1.6876.100.1.0.8061314 vmwAWSThrottlingExceptionEvent Critical AWS Throttling Exception AWS Throttling Exception
1.3.6.1.4.1.6876.100.1.0.8061315 vmwAWSFlowLogAccessDeniedExceptionEvent Critical AWS Flow Log Access Denied Exception AWS Flow Log Access Denied Exception. This alert is raised when user does not have necessary permissions required to collect flow logs.
1.3.6.1.4.1.6876.100.1.0.80614 vmwNotFoundEvent Critical Not Found Alert Not Found
1.3.6.1.4.1.6876.100.1.0.80616 vmwInvalidConfigEvent Critical Invalid Data Source Config Invalid Data Source Config
1.3.6.1.4.1.6876.100.1.0.80617 vmwWarnConfigEvent Critical Invalid Data Source Config Invalid Data Source Config
1.3.6.1.4.1.6876.100.1.0.80618 vmwUnexpectedDSTypeOrVersionEvent Critical Unexpected Datasource Type or Version Unexpected Datasource Type or Version
1.3.6.1.4.1.6876.100.1.0.80619 vmwNSXControllerNotFoundEvent Critical NSX Controller Not Found NSX Controller Not Found
1.3.6.1.4.1.6876.100.1.0.80620 vmwHostNotReachableEvent Critical Host Not Reachable Host Not Reachable
1.3.6.1.4.1.6876.100.1.0.80621 vmwInvalidResponseFromDatasourceEvent Critical Invalid Response From Data Source Invalid Response From Data Source
1.3.6.1.4.1.6876.100.1.0.80622 vmwDataProviderNotRunningEvent Critical Data Source Not Running Data Source Not Running
1.3.6.1.4.1.6876.100.1.0.80623 vmwPrimaryNSXNotAddedEvent Critical Primary NSX Not Added Primary NSX Not Added
1.3.6.1.4.1.6876.100.1.0.80624 vmwHostnameResolutionErrorEvent Critical Hostname Resolution Error Hostname Resolution Error
1.3.6.1.4.1.6876.100.1.0.80625 vmwNumVMsOrHostsNotFoundEvent Critical Number of Vms or Hosts Not Found Number of Vms or Hosts Not Found
1.3.6.1.4.1.6876.100.1.0.80626 vmwNSXIPFIXStatusMismatchEvent Critical NSX IPFIX Status Mismatch NSX IPFIX Status Mismatch
1.3.6.1.4.1.6876.100.1.0.80627 vmwFlowPhysicalNodeEvent Critical Flow Physical Node Alert Flow Physical Node
1.3.6.1.4.1.6876.100.1.0.80628 vmwNotEmptyNodeEvent Critical Not Empty Node Alert Not Empty Node
1.3.6.1.4.1.6876.100.1.0.80629 vmwUnsupportedNSXTVersionEvent Critical Unsupported NSXT Version Unsupported NSXT Version
1.3.6.1.4.1.6876.100.1.0.80630 vmwComputeManagersNotFoundEvent Critical Compute Managers Not Found Compute Managers Not Found
1.3.6.1.4.1.6876.100.1.0.80631 vmwComputeManagersNotAddedEvent Critical Compute Managers Not Added Compute Managers Not Added
1.3.6.1.4.1.6876.100.1.0.80632 vmwUnsupportedLogInsightVersionEvent Critical Log Insight version not supported Log Insight version not supported
1.3.6.1.4.1.6876.100.1.0.80633 vmwUnsupportedVRNIContentPackVersionEvent Critical vRealize Network Insight Content Pack version not supported vRealize Network Insight Content Pack version not supported
1.3.6.1.4.1.6876.100.1.0.80634 vmwVRNIContentPackNotInstalledEvent Critical vRealize Network Insight Content Pack not found in Log Insight vRealize Network Insight Content Pack not found in Log Insight
1.3.6.1.4.1.6876.100.1.0.80635 vmwWebhookNotEnabledOnAlertEvent Critical Webhook not enabled on a Network Insight alert Webhook not enabled for one or more alerts of vRealize Network Insight Content Pack in Log Insight
1.3.6.1.4.1.6876.100.1.0.80636 vmwIncorrectWebhookConfiguredOnAlertEvent Critical Incorrect webhook URL configured on a Log Insight alert Incorrect webhook configuration found for one or more alerts of vRealize Network Insight Content Pack in Log Insight
1.3.6.1.4.1.6876.100.1.0.80637 vmwWebhookNotRunningEvent Critical Webhook is not running on the Collector(Proxy) VM Webhook is not running on the Collector(Proxy) VM
1.3.6.1.4.1.6876.100.1.0.80638 vmwInfobloxRecordLimitExceededEvent Critical The number of records from Infoblox exceeds current limit The number of records from Infoblox exceeds current limit
1.3.6.1.4.1.6876.100.1.0.80639 vmwIncorrectInfobloxCredentialEvent Critical Incorrect Infoblox Credentials Infoblox credentials are invalid or the user does not have the "API Privilege" to access Infoblox data
1.3.6.1.4.1.6876.100.1.0.80640 vmwUnsupportedInfobloxVersionEvent Critical Unsupported Infoblox Version The version of NIOS is not supported.
1.3.6.1.4.1.6876.100.1.0.80641 vmwUnknownInfobloxVersionEvent Critical Unknown Infoblox Version The version of NIOS cannot be determined.
1.3.6.1.4.1.6876.100.1.0.80642 vmwNoDVSAvailableEvent Critical IPFIX cannot be enabled IPFIX cannot be enabled since no DVS found
1.3.6.1.4.1.6876.100.1.0.80643 vmwVCNotOnSameProxyEvent Critical NSX Manager and the vCenter DataSource not on the same Collector VM NSX Manager and the associated vCenter DataSources is not on the same Collector VM.
1.3.6.1.4.1.6876.100.1.0.80644 vmwNSXTIPFixNoCollectorProfileEvent Critical NSX-T IPFIX No Collector Profile NSXT IPFIX No Collector Profile
1.3.6.1.4.1.6876.100.1.0.80645 vmwNSXTIPFixNoNewCollectorProfileCanBeAddedEvent Critical NSX-T IPFIX no new Collector Profile can be added NSXT IPFIX no new Collector Profile can be added
1.3.6.1.4.1.6876.100.1.0.80646 vmwNSXTIPFixNoIPFixProfileEvent Critical NSX-T IPFIX No Ipfix Profile NSXT IPFIX No Ipfix Profile
1.3.6.1.4.1.6876.100.1.0.80647 vmwNSXTIPFixIPFixProfilePriorityNotZeroEvent Critical NSX-T IPFIX Ipfix Profile Priority not zero NSXT IPFIX Ipfix Profile Priority not zero
1.3.6.1.4.1.6876.100.1.0.80648 vmwNSXTIPFixCollectorAndIPFixProfileMismatchEvent Critical NSX-T IPFIX Collector and Ipfix Profile Mismatch NSXT IPFIX Collector and Ipfix Profile Mismatch
1.3.6.1.4.1.6876.100.1.0.80649 vmwNSXTIPFixPortIncorrectEvent Critical NSX-T IPFIX Collector Port Incorrect Collector Port in Collector Profile is incorrect
1.3.6.1.4.1.6876.100.1.0.80650 vmwNSXTIPFixDFWStatusNotEnabledEvent Critical NSX-T IPFIX DFW is not Enabled NSX-T IPFIX DFW is not Enabled
1.3.6.1.4.1.6876.100.1.0.80651 vmwPolicyManagerNoDfwIPFixProfile Critical DFW IPFIX Profile absent on NSX Policy Manager DFW IPFIX Profile is not found on NSX Policy Manager
1.3.6.1.4.1.6876.100.1.0.80652 vmwPolicyManagerVrniDfwIPFixCollectorAbsent Critical Network Insight IPFIX Collector configuration is absent on NSX Policy Manager Network Insight IPFIX Collector IP and port are not present in DFW IPFIX Collector Profile on NSX Policy Manager.
1.3.6.1.4.1.6876.100.1.0.80653 vmwDatasourceIdentificationChangedEvent Info Identity information for Data Source changed The data source identity information such as certificate or the key has changed.
1.3.6.1.4.1.6876.100.1.0.80654 vmwPKSKubernetesUnknownHostEvent Critical Kubernetes Cluster API Servers not reachable One or more Kubernetes Cluster's Kube Config file in PKS is not valid.
1.3.6.1.4.1.6876.100.1.0.80655 vmwKubernetesInsufficientPrivilegesEvent Critical Kubernetes Cluster Service Accounts do not have sufficient privileges One or more Kubernetes Cluster Service Accounts do not have sufficient privileges.
1.3.6.1.4.1.6876.100.1.0.80657 vmwUANIFileNotProvidedEvent Critical File required by Generic Routers & Switches Data Source not provided File required by Generic Routers & Switches Data Source not provided
1.3.6.1.4.1.6876.100.1.0.80658 vmwUANIFileDoesNotExistEvent Critical File required by Generic Routers & Switches Data Source does not exist File required by Generic Routers & Switches Data Source does not exist
1.3.6.1.4.1.6876.100.1.0.80659 vmwNSXTLatencyNotEnabledEvent Critical NSXT_LATENCY_NOT_ENABLED_EVENT NSX-T latency collection is not enabled
1.3.6.1.4.1.6876.100.1.0.80660 vmwNSXTLatencyMoreBFDProfileEvent NSXT_LATENCY_MORE_BFD_PROFILE_EVENT
1.3.6.1.4.1.6876.100.1.0.80662 vmwNSXTLatencyCollectorMismatchEvent Critical NSXT_LATENCY_COLLECTOR_MISMATCH_EVENT NSX-T latency collector not configured
1.3.6.1.4.1.6876.100.1.0.80663 vmwBigIpInsufficientShellAccessEvent Critical BIGIP_INSUFFICIENT_SHELL_ACCESS_EVENT No access to shell
1.3.6.1.4.1.6876.100.1.0.80664 vmwBigIpInsufficientPartitionAccessEvent Critical BIGIP_INSUFFICIENT_PARTITION_ACCESS_EVENT Insufficient Partition Access
1.3.6.1.4.1.6876.100.1.0.80665 vmwBigIpInsufficientRoleEvent Critical BIGIP_INSUFFICIENT_ROLE_EVENT Insufficient Role
1.3.6.1.4.1.6876.100.1.0.90001 vmwVeloCloudEdgeDownEvent Warning VeloCloud Edge is not healthy Edge State of VeloCloud Edge is not connected.
1.3.6.1.4.1.6876.100.1.0.90002 vmwVeloCloudLinkDownEvent Warning VeloCloud Link is not healthy Link State of VeloCloud Edge is not connected.
1.3.6.1.4.1.6876.100.1.0.90005 vmwVeloCloudLinkLostPacketEventTx Critical VeloCloud Link Upstream Packet Loss exceeds threshold. VeloCloud Link Tx Packet Loss.
1.3.6.1.4.1.6876.100.1.0.90007 vmwVeloCloudLinkDegradedVoiceQoeEvent Critical VeloCloud Link Voice QOE degraded. VeloCloud Link Voice QOE Degraded.
1.3.6.1.4.1.6876.100.1.0.90008 vmwVeloCloudLinkDegradedVideoQoeEvent Critical VeloCloud Link Video QOE degraded. VeloCloud Link Video QOE Degraded.
1.3.6.1.4.1.6876.100.1.0.90009 vmwVeloCloudLinkDegradedTransQoeEvent Critical VeloCloud Link Transactional QOE degraded. VeloCloud Link Transactional QOE Degraded.
1.3.6.1.4.1.6876.100.1.0.90010 vmwVeloCloudEdgeDegradedVoiceQoeEvent Critical VeloCloud Edge Voice QOE degraded. VeloCloud Edge Voice QOE degraded.
1.3.6.1.4.1.6876.100.1.0.90011 vmwVeloCloudEdgeDegradedVideoQoeEvent Critical VeloCloud Edge Video QOE degraded. VeloCloud Edge Video QOE degraded.
1.3.6.1.4.1.6876.100.1.0.90012 vmwVeloCloudEdgeDegradedTransQoeEvent Critical VeloCloud Edge Transactional QOE degraded. VeloCloud Edge Transactional QOE degraded.
1.3.6.1.4.1.6876.100.1.0.90013 vmwVeloCloudLinkLostPacketEventRx Critical VeloCloud Link Downstream Packet Loss exceeds threshold. VeloCloud Link RX Packet Loss.
1.3.6.1.4.1.6876.100.1.0.90017 vmwSDWanLinkTrafficThresholdEvent Moderate SD-WAN Link Utilization Exceeded SD-WAN Link Traffic exceeded the threshold limit configured.
1.3.6.1.4.1.6876.100.1.0.974 vmwNSXIApplianceAvailableEvent Info NSX Intelligence Appliance Available This event is raised when vRealize Network Insight detects that NSX Intelligence appliance is available for an NSX-T data source.
1.3.6.1.4.1.6876.100.1.0.975 vmwNSXISubscriptionCreateFailedEvent Critical Failed to enable data collection from NSX Intelligence This event is raised when vRealize Network Insight is unable to create a subscription with the NSX Intelligence Appliance.
1.3.6.1.4.1.6876.100.1.0.976 vmwNSXISubscriptionDeleteFailedEvent Critical NSX Intelligence cleanup failed This event is raised when vRealize Network Insight is unable to delete a subscription with the NSX Intelligence Appliance.
1.3.6.1.4.1.6876.100.1.0.977 vmwNSXISubscriptionUpdateFailedEvent Critical Failed to initiate data collection from NSX Intelligence This event is raised when vRealize Network Insight is unable to update a subscription with the NSX Intelligence Appliance.
1.3.6.1.4.1.6876.100.1.0.978 vmwNSXISSLHandshakeFailedEvent Critical NSX Intelligence SSL Handshake Failed This event is raised when the SSL Handshake between vRealize Network Insight Collector and NSX Intelligence Appliance fails.