To send the NetFlow information to the
vRealize Network Insight NetFlow collector, configure the physical device manually. Here are the steps for the configuration in most of the physical devices:
- Create a flow record.
The required fields for a flow record are as follows:
- Mark the following fields as
Match.-
ipv4 protocol -
ipv4 source address -
ipv4 destination address -
transport source-port -
transport destination-port -
interface input
-
- Mark the following fields as
Collect.-
direction -
counter bytes -
counter packets -
timestamp sys-uptime first -
timestamp sys-uptime last
-
- Mark the following field as
MatchorCollect. If not, skip it.transport tcp flags
- Mark the following fields as
- Create a flow exporter.
- Provide vRealize Network Insight NetFlow collector IP and port 2055.
- Configure the flow cache as follows:
- Active timeout: 30 seconds
- Inactive timeout: 60 seconds
- Create the flow monitor using the created flow record and flow exporter.
- Configure the monitor on each interface.
Prerequisites
Example
The sample steps to configure the physical devices are provided in the following sections:
Note: The steps may vary from version to version and device to device.