You can add Dell switches as a data source in vRealize Network Insight.
Prerequisites
- You must have the following permission:
- Read-only user: vRealize Network Insight requires read-only third-party device credentials (passwords) to access the SSH data. This user needs to have the Network Operator role. These passwords are added when configuring the third-party data provider in vRealize Network Insight user interface.
- Read-only SNMP user: vRealize Network Insight uses SNMP to collect metrics information from third-party devices (switches, routers, firewalls, and so on). The third-party devices must have SNMP enabled and be accessible from vRealize Network Insight.
- To use Network Assurance and Verification feature (Network Map), you must have a netadmin role with privilege level 15 for accessing all the show commands on the system. See Dell EMC SmartFabric OS10 User Guide for details.
Procedure
- On the Settings page, click Accounts and Data Sources.
- Click Add Source.
- Under Routers & Switches, click the Dell devices that you want to add and provide the required information.
Option |
Action |
Collector VM |
Select a collector VM from the drop-down menu. |
IP Address/FQDN |
Enter the IP address or the FQDN details. |
Username |
Enter the user name. |
Password |
Enter the password. |
Note: If you want to add Dell S4048, Z9100, or S6000 devices in
vRealize Network Insight as a data source and if that Dell device is running on OS 10, then you must select
Dell OS10 as an account or a source type while adding that Dell device as a data source in
vRealize Network Insight.
- Click Validate.
- To enable a richer data collection, click Use SNMP (recommended for richer data collection) check box, and do the following:
- From the SNMP Version drop-down menu, select an SNMP version. Depending on which version of SNMP you have selected, do the following:
Option |
Action |
2c |
In the Community String text box, enter a community string. |
3 |
- Enter Username, Context Name.
- From the Authentication Type drop-down, select an authentication type and enter the Authentication Password.
- From the Privacy Type drop-down, select a privacy type and enter the Privacy Password.
|
- Define the polling interval for the configuration data collection. You can set the polling interval from 10 minutes to 7 days.
- Preset - Select the interval time from the predefined time set.
- Custom Interval - Set a value and select Minutes, Hours, and Days.
- In the Nickname text box, enter a nickname.
- (Optional) In the Notes text box, you can add a note if necessary.
- Click Submit.
What to do next
For Dell OS10 Switches,
Enable telemetry on Dell OS10 switches.