You can add VMware vCenter servers as data source in vRealize Network Insight Cloud.
Multiple VMware vCenter servers can be added to vRealize Network Insight Cloud to start monitoring data.
Note: To bring
vRealize Network Insight Cloud data into
VMware vCenter, use the vCenter Plug-in for
vRealize Network Insight Cloud. To know about how to install and use the plug-in, see
vCenter Plugin for vRealize Network Insight.
Prerequisites
- The predefined roles in the VMware vCenter server must have the following privileges assigned at root level. These privileges must be propagated to the children roles:
- System.Anonymous
- System.Read
- System.View
- Global.Settings
- To configure and use IPFIX, the following VMware vCenter server privileges are required:
- Distributed switch: Modify and Port configuration operation
- dvPort group: Modify and Policy operation
Note: IPFIX is supported on the following VMware ESXi versions:
- 5.5 Update 2 (Build 2068190) and later.
- 6.0 Update 1b (Build 3380124) and later.
- VMware VDS 5.5 and later.
- To identify the VM to VM path, you must install VMware tools on all the VMs in the data center .
To know more about roles in
VMware vCenter, see the
vSphere Security guide.
Procedure
- Go to .
- Click Add Source.
- Under VMware Managers, select VMware vCenter.
- Provide the following details:
Option |
Action |
Collector VM |
Select a collector VM from the drop-down menu.
Note: You can add maximum 10
VMware vCenter Server per collector.
|
IP Address/FQDN |
Enter the IP address ( IPv4 address or IPv6 address) or fully qualified domain name of the VMware vCenter server.
Note: You must add the data source using either IP address or FQDN. Do not add the data source using both IP address and FQDN.
|
Username |
Enter the user name with the following privileges:
- Distributed Switch: Modify
- dvPort group: Modify
|
Password |
Enter the password for vRealize Network Insight Cloud software to access the VMware vCenter Server system. |
- Click Validate.
If the number of VMs discovered exceeds the capacity of the platform or a collector node or both, the validation fails. You will not be allowed to add a data source until you increase the brick size of the platform or create a cluster.
The specified capacity for each brick size with and without flows is as follows:
Brick Size |
VMs |
State of Flows |
Large |
6k |
Enabled |
Large |
10k |
Disabled |
Medium |
3k |
Enabled |
Medium |
6k |
Disabled |
- Select Enable Netflow (IPFIX) on this vCenter to enable IPFIX.
For more information on IPFIX, see the
Enabling IPFIX Configuration on VDS and DVPG topic.
Note:
- You cannot enable IPFIX on DVPGs that have NSX-T Edges connected.
- If you enable IPFIX in both VMware vCenter and VMware NSX Manager, vRealize Network Insight Cloud automatically detects and removes flow redundancies by disabling IPFIX on few of the DVPGs for the associated VMware vCenter.
- Add advanced data collection sources to your VMware vCenter server system.
- (Optional) In the Nickname text box, enter a nickname.
- (Optional) In the Notes text box, add a note if necessary.
- Click Submit.
Results
The
VMware vCenter server systems appear on the homepage.