Alarms privileges control the ability to create, modify, and respond to alarms on inventory objects.

You can set this privilege at different levels in the hierarchy. For example, if you set a privilege at the folder level, you can propagate the privilege to one or more objects within the folder. The object listed in the Required On column must have the privilege set, either directly or inherited.

Table 1. Alarms Privileges
Privilege Name Description Required On
Alarms.Acknowledge alarm

Allows suppression of all alarm actions on all triggered alarms.

Object on which an alarm is defined

Alarms.Create alarm

Allows creation of a new alarm.

When creating alarms with a custom action, privilege to perform the action is verified when the user creates the alarm.

Object on which an alarm is defined

Alarms.Disable alarm action

Allows stopping an alarm action from occurring after an alarm has been triggered. This does not disable the alarm.

Object on which an alarm is defined

Alarms.Disable or enable alarm on entity Allows enabling or disabling a particular alarm on a particular target type.

Object on which the alarm can trigger

Alarms.Modify alarm

Allows changing the properties of an alarm.

Object on which an alarm is defined

Alarms.Remove alarm

Allows deletion of an alarm.

Object on which an alarm is defined

Alarms.Set alarm status

Allows changing the status of the configured event alarm. The status can change to Normal, Warning, or Alert.

Object on which an alarm is defined